Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitodens 200-W (B2HB)

Viessmann Vitodens 200-W B2HB 45, 160

The Vitodens 200-W B2HB 45, 160 opens the B2HB large chassis: 32 to 160 MBH natural gas input (60 to 160 MBH propane) at 95.0% AFUE in a 210 lb (95 kg) wall-hung boiler with a 60 psig rating.

DiscontinuedHistorically in Canada

Key figures

Max input
160 MBH
Max CSA output
AFUE
95 %
Min input
32 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitodens 200-W B2HB 45, 160 in practice

The B2HB 45, 160 is the first model of the B2HB large chassis group: printed natural gas input 32-160 MBH (9-47 kW), propane 60-160 MBH (17.5-47 kW), output 30-149 MBH (9-44 kW) and a 127 MBH Net AHRI rating at 95.0% AFUE.

The chassis step brings 210 lb (95 kg) of weight, 3.85 USG of boiler water, a 60 psig maximum operating pressure and a 19 x 21 x 43.5 in (480 x 530 x 1105 mm) cabinet. Unlike the smaller B2HB sizes, the 45 and the 57, 199 can be common-vented — but only with other Vitodens 200-W boilers of the same size and series.

Best suited to

  • Large homes whose heat-loss calculation needs more than 125 MBH
  • Plants planning common venting of same-size Vitodens 200-W boilers
  • Owners of existing B2HB 45/160 units looking up printed ratings

Applicability and support

Model number
B2HB 45, 160
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitodens 200-W B2HB 45, 160 specifications
SpecificationValueNote
Input
CSA input, minimum (natural gas)32 MBH9 kW, per the technical data manual
CSA input, maximum (natural gas)160 MBH47 kW, per the technical data manual
CSA input (liquid propane)60-160 MBHPrinted LPG range; minimums are higher than natural gas on the 26/94 and larger sizes.
Output
CSA output / DOE heating capacity (natural gas)30-149 MBH9-44 kW, based on 140°F / 120°F supply/return
Net AHRI rating127 MBHBased on piping and pick-up allowance of 1.15.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE on all B2HB sizes per the technical data manual; up to 98% at full modulation.
Physical and connections
Weight210 lb95 kg
Width19 in480 mm
Depth21 in530 mm
Height43.5 in1105 mm
Operating limits and other
FuelNatural gas or liquid propaneAs printed in the technical data manual's CSA input rows.
Boiler water content3.85 USG
Maximum operating pressure60 psigAt 210°F (99°C).

Frequently asked questions

What is the input range of the B2HB 45, 160?

32-160 MBH (9-47 kW) natural gas and 60-160 MBH (17.5-47 kW) propane, with 30-149 MBH output, a 127 MBH Net AHRI rating and 95.0% AFUE.

How heavy is the B2HB 45, 160?

210 lb (95 kg), with 3.85 USG of boiler water and a 60 psig maximum operating pressure — the same large chassis as the B2HB 57, 199, measuring 19 x 21 x 43.5 in (480 x 530 x 1105 mm).

Can the B2HB 45, 160 be common-vented?

Yes, but only with other Vitodens 200-W boilers of the same size and series, per the technical data manual. It cannot be common-vented with the smaller B2HB models or other appliances.

Questions about the Viessmann Vitodens 200-W B2HB 45, 160?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate