Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Series

Viessmann Vitodens 200-W (B2HB)

The Vitodens 200-W B2HB is the previous-generation wall-hung condensing boiler that today's B2HE series replaced: five Canadian sizes from 12 to 199 MBH input at 95.0% AFUE, with a modulating MatriX cylinder burner and Inox-Radial stainless steel heat exchanger. Viessmann Canada still publishes its full documentation set in the current product manuals library.

discontinuedhistoricalNatural gasPropaneresidentialcommercial

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas or liquid propane, as printed in the technical data manual's CSA input rows. LPG minimum inputs are higher than natural gas on the 26/94, 35/125, 45/160 and 57/199 models (for example, 31 vs 19 MBH on the 35/125 and 60 vs 32 MBH on the 57/199).
Venting
Multiple venting options with vent length up to 180 ft (55 m) per the technical data manual. The B2HB 19, 26, 35, 68, 94 and 125 models must not be common-vented with any other appliance; the B2HB 45, 57, 160 and 199 models can only be common-vented with other Vitodens 200-W boilers of the same size and series.
Models documented
5

95.0% AFUE on all five B2HB sizes per the technical data manual, which also cites up to 98% at full modulation.

About the Vitodens 200-W (B2HB)

The B2HB generation of the Vitodens 200-W was Viessmann Canada's flagship wall-hung condensing boiler before the B2HE: a gas-fired, wall-mounted unit with a modulating MatriX cylinder burner and an Inox-Radial stainless steel heat exchanger, rated 95.0% AFUE with up to 98% at full modulation and vent runs up to 180 ft (55 m). Its five Canadian sizes are B2HB 19/68, 26/94, 35/125, 45/160 and 57/199, printed in the technical data manual as natural gas input ranges of 12-68, 19-94, 19-125, 32-160 and 32-199 MBH respectively.

The line splits into two chassis groups. The 19/68, 26/94 and 35/125 models weigh 110 lb (50 kg) with 1.02 USG of boiler water and a 45 psig maximum operating pressure; the 45/160 and 57/199 models step up to 210 lb (95 kg), 3.85 USG and 60 psig. All five print 95.0% AFUE and a Net AHRI rating from 55 to 160 MBH, and the 45, 57, 160 and 199 models can be common-vented with other Vitodens 200-W boilers of the same size and series.

The B2HB is no longer sold new — the current catalogue is the B2HE, which Viessmann Canada lists with no fuel-conversion kit required — but the B2HB documentation set remains live on Viessmann Canada's current product manuals page, including the technical data manual (doc 5461 883 - 18, 04/2025) and separate installation and service instructions for the 19-35 and 45-57 size groups. Boilers.ca documents the printed per-size rows here so owners and servicers of existing units can look up inputs, outputs, weights and dimensions.

Highlights

  • Previous-generation wall-hung condensing boiler, superseded by the Vitodens 200-W B2HE
  • Five Canadian sizes: B2HB 19/68, 26/94, 35/125, 45/160 and 57/199
  • Printed natural gas input 12 to 199 MBH; LPG input ranges print separately with higher minimums
  • 95.0% AFUE on all sizes; up to 98% at full modulation per the technical data manual
  • Two chassis groups: 110 lb (50 kg) for 19-35, 210 lb (95 kg) for 45-199
  • Full documentation set still published in Viessmann Canada's current product manuals

Viessmann Canada publishes a Standard Limited Warranty (doc 6167 816 - 07) for Vitodens units bought on or after June 1, 2021: the pressure vessel is covered 100% for ten years, then under the residential 'limited lifetime' terms on a prorated scale; covered parts carry a two-year term.

Models

Vitodens 200-W (B2HB) models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedHistorically in Canada
Input
12–68 MBH
Output (max)
—
AFUE
95 %

The Vitodens 200-W B2HB 19, 68 is the smallest model of the previous-generation 200-W line: 12 to 68 MBH input at 95.0% AFUE in a 110 lb (50 kg) wall-hung cabinet, with a 55 MBH Net AHRI rating and a 45 psig maximum operating pressure.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
19–94 MBH
Output (max)
—
AFUE
95 %

The Vitodens 200-W B2HB 26, 94 steps the previous-generation line to 94 MBH: 19 to 94 MBH natural gas input (31 to 94 MBH on propane) at 95.0% AFUE in the 110 lb (50 kg) compact cabinet.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
19–125 MBH
Output (max)
—
AFUE
95 %

The Vitodens 200-W B2HB 35, 125 is the largest model of the B2HB compact chassis: 19 to 125 MBH natural gas input (31 to 125 MBH propane) at 95.0% AFUE with a 102 MBH Net AHRI rating.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
32–160 MBH
Output (max)
—
AFUE
95 %

The Vitodens 200-W B2HB 45, 160 opens the B2HB large chassis: 32 to 160 MBH natural gas input (60 to 160 MBH propane) at 95.0% AFUE in a 210 lb (95 kg) wall-hung boiler with a 60 psig rating.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
32–199 MBH
Output (max)
—
AFUE
95 %

The Vitodens 200-W B2HB 57, 199 is the top of the previous-generation B2HB line: 32 to 199 MBH natural gas input (60 to 199 MBH propane) at 95.0% AFUE in the 210 lb (95 kg) large chassis.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Viessmann Vitodens 200-W B2HB 19, 68 and Viessmann Vitodens 200-W B2HB 26, 94 and Viessmann Vitodens 200-W B2HB 35, 125 and Viessmann Vitodens 200-W B2HB 45, 160 and Viessmann Vitodens 200-W B2HB 57, 199
SpecificationViessmann Vitodens 200-W B2HB 19, 68Viessmann Vitodens 200-W B2HB 26, 94Viessmann Vitodens 200-W B2HB 35, 125Viessmann Vitodens 200-W B2HB 45, 160Viessmann Vitodens 200-W B2HB 57, 199
CSA input, minimum (natural gas)12 MBH19 MBH19 MBH32 MBH32 MBH
CSA input, maximum (natural gas)68 MBH94 MBH125 MBH160 MBH199 MBH
output-max—————
Efficiency (AFUE)95 %95 %95 %95 %95 %
turndown—————
vent-max-3—————
vent-max-2—————
Weight110 lb110 lb110 lb210 lb210 lb

Read the full comparison: Viessmann Vitodens 200-W B2HB 19, 68 vs B2HB 26, 94 →

Read the full comparison: Viessmann Vitodens 200-W B2HB 26, 94 vs B2HB 35, 125 →

Read the full comparison: Viessmann Vitodens 200-W B2HB 35, 125 vs B2HB 45, 160 →

Read the full comparison: Viessmann Vitodens 200-W B2HB 45, 160 vs B2HB 57, 199 →

Error codes and alerts

Vitodens 200-W (B2HB) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Vitodens 200-W B2HB still sold in Canada?

No. The B2HB generation has been superseded by the Vitodens 200-W B2HE. Viessmann Canada still publishes the B2HB technical data, installation and service documents in its current product manuals library, so owners and servicers can still match documents to the unit.

What sizes does the B2HB line cover?

Five sizes: B2HB 19/68, 26/94, 35/125, 45/160 and 57/199. Printed natural gas input ranges are 12-68, 19-94, 19-125, 32-160 and 32-199 MBH; LPG inputs print separately, with higher minimums on the larger sizes.

Which B2HB models can be common-vented?

The technical data manual states the B2HB 45, 57, 160 and 199 models can only be common-vented with other Vitodens 200-W boilers of the same size and series, and that the 19, 26, 35, 68, 94 and 125 models must not be common-vented with any other appliance.

Is the B2HB covered by the Vitodens heat-exchanger safety notice?

Yes — Viessmann Canada's heat-exchanger replacement safety notice names Vitodens 200-W B2HB models 19, 26 and 35 manufactured between September 1, 2014 and April 25, 2017. Check the boiler's 16-digit serial number on the recall page or contact recall@viessmann.ca.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate