Weil-McLain GV90+

The GV90+ is Weil-McLain's high-efficiency cast iron boiler with a stainless steel secondary heat exchanger — Series 2 in Canada, in four sizes from GV90+3 (70 MBH) to GV90+6 (175 MBH), rated up to 91.9% AFUE and vented in 3" PVC like a condensing boiler.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
91.9% AFUE
Fuel
Natural gas or propane; the CA product page lists propane with a conversion kit needed.
Venting
Category IV direct vent or direct exhaust in 3" PVC or polypropylene (AL29-4C and CPVC are also listed on the CA page), to 100 ft maximum. Canadian installations follow CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit, per the boiler manual.
Models documented
4

Up to 91.9% AFUE (the GV90+3); the four Series 2 models rate 91.0-91.9% AFUE.

About the GV90+

The GV90+ is not a condensing boiler: Weil-McLain's materials call it a "high-efficiency cast iron boiler" built around durable cast iron sections with a stainless steel condensing secondary heat exchanger that recovers exhaust heat, and the CA page lists its materials as cast iron and stainless steel. Four Series 2 models — GV90+3 through GV90+6 — fire from 70 to 175 MBH input and rate 91.0-91.9% AFUE.

Series 2 added a built-in low water cut-off with test button and an integrated dual-circulator arrangement. The boiler has no text display: the IBC control reports conditions through indicator lights and POWER-LED flash codes (flash codes 2-6 for hard lockouts), which is why Boilers.ca describes GV90+ diagnostics separately from the text-fault series.

All four sizes vent in 3" PVC, polypropylene or the other approved materials to 100 ft, and the manual carries its own altitude output de-rate table (for example, output de-rates to about 83% of sea level at 5,000 ft). The CA page lists 20-year cast iron heat exchanger coverage and notes the boiler includes a water inhibitor and boiler and recirculation pumps.

Highlights

  • High-efficiency cast iron with stainless steel secondary heat exchanger
  • Four sizes, GV90+3 to GV90+6 (70-175 MBH), up to 91.9% AFUE
  • Series 2 with built-in low water cut-off
  • IBC control uses indicator lights and POWER-LED flash codes — no display
  • 3" Category IV venting to 100 ft, including PVC
  • Current in both Canada and the US

Residential: 20-year cast iron heat exchanger / 5-year stainless steel heat exchanger / 2-year parts; commercial: 10-year cast iron / 5-year stainless steel / 1-year parts, per the CA product page.

Models

GV90+ models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
—
Output (max)
65 MBH
AFUE
91.9 %

The GV90+3 is the smallest Series 2 GV90+: 70 MBH input, 65 MBH DOE heating capacity and a 91.9% AFUE rating — the highest in the line — from the cast iron boiler with stainless steel secondary heat exchanger.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
—
Output (max)
97 MBH
AFUE
91.2 %

The GV90+4 steps the cast iron line to 105 MBH input and 97 MBH DOE heating capacity at 91.2% AFUE, keeping the 30-3/4" cabinet length with 4.7 gallons of boiler water.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
—
Output (max)
130 MBH
AFUE
91.4 %

The GV90+5 is the first of the long-cabinet GV90+ sizes: 140 MBH input, 130 MBH DOE heating capacity and a 113 MBH net AHRI rating at 91.4% AFUE, in a 37-3/4" unit.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
—
Output (max)
161 MBH
AFUE
91 %

The GV90+6 is the largest GV90+ at 175 MBH input and 161 MBH DOE heating capacity — 91.0% AFUE in the 37-3/4" cabinet with 6.9 gallons of boiler water.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Weil-McLain GV90+3 and Weil-McLain GV90+4 and Weil-McLain GV90+5 and Weil-McLain GV90+6
SpecificationWeil-McLain GV90+3Weil-McLain GV90+4Weil-McLain GV90+5Weil-McLain GV90+6
input-min————
Input, maximum70 MBH105 MBH140 MBH175 MBH
DOE heating capacity65 MBH97 MBH130 MBH161 MBH
Efficiency (AFUE)91.9 %91.2 %91.4 %91 %
turndown————
vent-max-3————
vent-max-2————
Weight313 lb353 lb423 lb464 lb

Read the full comparison: Weil-McLain GV90+3 vs GV90+4 →

Read the full comparison: Weil-McLain GV90+4 vs GV90+5 →

Read the full comparison: Weil-McLain GV90+5 vs GV90+6 →

Read the full comparison: Weil-McLain GV90+3 vs GV90+5 →

Error codes and alerts

GV90+ alerts

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the GV90+ a condensing boiler?

No. Weil-McLain markets it as a high-efficiency cast iron boiler with a stainless steel condensing secondary heat exchanger — it is vented as a Category IV appliance but official materials never call the GV90+ a condensing boiler.

How do you read GV90+ fault codes?

The GV90+ has no display. Its IBC control reports hard lockouts through combinations of indicator lights and POWER-LED flash codes, which the Series 2 boiler manual documents; low-water cut-off activation is one of the flash-code conditions.

What does the + in GV90+ mean?

The GV90+ name marks the high-efficiency generation of the cast iron GV line. Canada sells the current Series 2 with the built-in low water cut-off; Series 1 units predate that feature.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate