HTP UFT Combi Er:29 — Aps (air Pressure Switch) — Closed is Normal, Open is Fault
Er:29
APS (air pressure switch) — closed is normal, open is fault. Press the Power button to clear. WARNING: if Er:29 occurs, turn off the gas valve at the manual shutoff and check the vent terminations for obstructions before resetting. Check APS and main controller connections are secure; check APS resistance (if not zero, replace the switch); check the APS hose is connected and in good condition; check the condensate line and termination for blockages; check the exhaust vent for blockages; if the problem persists replace the main control. The table classifies it as Error (Soft/Hard Lockout).
If you smell gas
- Stop what you are doing. Do not use phones, switches, matches or anything that can spark inside.
- Go outside and leave the door open behind you.
- Call the FortisBC 24-hour emergency line at 1-800-663-9911 or dial 911.
Only after that, call ROMA about the boiler. Official guidance: FortisBC gas leaks and odour.
Applies to
This gas-train fault code is displayed by the UFTC control on UFT Combi models (UFTC-140/199), as documented in UFT Combi Installation Manual, LP-648 Rev. 002 Rel. 002 (9.16.20), Table 30 (LP-648). Codes can differ between controller generations, so always check the manual that matches your unit.
Controller: UFTC control. Source manual: LP-648.
Why a code is not a diagnosis
A gas-train code involves the gas valve or its electrical circuit. It does not mean there is a leak; the circuit, coils and wiring must be measured by a licensed technician.
Safe things to observe
- If you smell gas, stop, go outside and call your gas utility's emergency line or 911 before anything else.
- Note the exact code and what the appliance was doing when it appeared.
- Check whether other gas appliances in the building are working.
Do not
- Do not reset or run the appliance while the gas valve circuit is suspect.
- Do not touch the gas valve.
How professional service helps
- A technician verifies harness connections and coil resistances against the manual before replacing parts.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Gas valve
The gas valve is the boiler's controlled gateway for gas: it opens only when the control has proven safe conditions, meters the fuel to the burner,…
What a technician checks →Air pressure switch
An air pressure switch proves that the combustion fan is moving air and that the vent path is clear before the boiler is allowed to fire.
What a technician checks →Vent terminal
The vent terminal is where a boiler's exhaust and combustion-air pipes meet the outdoors, and keeping it clear is one of the few combustion tasks a…
What a technician checks →Boiler venting (flue and air intake)
A condensing boiler vents cool, wet flue gases through dedicated plastic pipe that must meet ULC S636 in Canada and the boiler manufacturer's own…
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
- Emergency Boiler Repair
Priority gas boiler repair for homes and buildings in Greater Vancouver with no heat, no hot water, a locked-out boiler or a leak.
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for HTP UFT Combi (discontinued).
Frequently asked questions
Does this code mean I have a gas leak?
Not by itself. If you smell gas, stop, leave the building and call your gas utility's emergency line or 911 from outside before anything else. Otherwise the code points to a fault a technician confirms on site.
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- UFT Combi Installation Manual, LP-648 Rev. 002 Rel. 002 (9.16.20), Table 30 · LP-648 · accessed September 8, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.