HTP UFT Combi (discontinued)

The UFT Combi (UFTC) is HTP's retired combination boiler: wall models UFTC-140W and UFTC-199W and floor models UFTC-140F and UFTC-199F, with printed CH inputs of 14,000-140,000 (140) or 19,900-140,000 (199) BTU/hr, DHW inputs up to 199,000 BTU/hr, 95-96% printed AFUE and a 10-year limited warranty.

discontinuedunknownNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
96% AFUE
Fuel
LP-646 prints 'Models Available for Natural or LP Gas'.
Venting
Unknown
Models documented
4

The mktlit-115 brochure and LP-648 Table 8 print 96% for the 140 models and 95% for the 199 (brochure prints 95.1 for the 199); LP-646 prints 'Up to 96% AFUE'.

About the UFT Combi (discontinued)

The UFT Combi is documented on HTP's retired UFT Combination documents page, which states verbatim 'This products has been discontinued, please see the below documentation for support.' The mktlit-115 brochure and LP-648 Table 8 print four configurations — UFTC-140 and UFTC-199 in wall ('W') or floor ('F') mount — with DHW inputs of 14,000-140,000 (140) or 19,000/19,900-199,000 (199) BTU/hr, boiler inputs of 14,000-140,000 (140) or 19,900-140,000 as shipped (199, increasable to 199,000 with a larger external pump), 95-96% AFUE and DHW flows of 7.1/5.5/3.2 GPM (140) or 9.9/7.7/4.8 GPM (199) at 35/45/77°F rises.

LP-648 Table 8 supplies the model-record rows: weights (110/120 lb wall, 140/150 lb floor), dimensions, 1" NPT CH and 3/4" NPT DHW connections, 3/4" NPT gas, CH 12-30 PSI and DHW 150 PSI maximum pressures, 2" (50 ft) or 3" (100 ft) venting, 1/1.5-gallon internal storage tanks with 4/3.5-gallon heat exchangers and the NGTX-900C / P-920C_CB-HTP control. The LP-646 submittal adds an ASME 'H' stamped 316L stainless steel heat exchanger, an internal 316L stainless steel indirect storage tank, a 10:1 modulating burner, a built-in low water cut-off, an installed internal pump and a 10-year limited warranty.

The UFT Combi is retired: the discontinued index lists 'UFT Combi Boiler - Wall & Floor' and the official documents page carries the discontinued wording above. Boilers.ca records the line with productStatus 'discontinued' and canadianStatus 'unknown'; no official Canadian sales statement was found. Service an installed unit with a licensed contractor against LP-648.

Highlights

  • Retired line: 'UFT Combi Boiler - Wall & Floor' on HTP's discontinued-products index
  • Official retired-page wording: 'This products has been discontinued, please see the below documentation for support.'
  • Four configurations: UFTC-140W/199W wall and UFTC-140F/199F floor
  • CH inputs 14,000-140,000 (140) and 19,900-140,000 as shipped (199); DHW up to 199,000 BTU/hr
  • ASME 'H' 316L stainless fire-tube exchanger with internal indirect storage tank; 10-year warranty

The LP-646 submittal prints a 10 Year Limited Warranty for the UFTC combined appliance.

Models

UFT Combi (discontinued) models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedCanadian status unknown
Input
14–140 MBH
Output (max)
AFUE
96 %

The HTP UFTC-140W is the wall-mount 140 MBH class combi of the retired UFT Combi line: 14,000 to 140,000 BTU/hr CH input, 14,000 to 140,000 BTU/hr DHW input and 96% AFUE, recorded from the official LP-648 technical table.

Natural gasPropaneCombi
DiscontinuedCanadian status unknown
Input
19.9–140 MBH
Output (max)
AFUE
95 %

The HTP UFTC-199W is the wall-mount 199 MBH class combi of the retired UFT Combi line: 19,900 to 140,000 BTU/hr CH input, 19,900 to 199,000 BTU/hr DHW input and 95% AFUE, recorded from the official LP-648 technical table.

Natural gasPropaneCombi
DiscontinuedCanadian status unknown
Input
14–140 MBH
Output (max)
AFUE
96 %

The HTP UFTC-140F is the floor-mount 140 MBH class combi of the retired UFT Combi line: 14,000 to 140,000 BTU/hr CH input, 14,000 to 140,000 BTU/hr DHW input and 96% AFUE, recorded from the official LP-648 technical table.

Natural gasPropaneCombi
DiscontinuedCanadian status unknown
Input
19.9–140 MBH
Output (max)
AFUE
95 %

The HTP UFTC-199F is the floor-mount 199 MBH class combi of the retired UFT Combi line: 19,900 to 140,000 BTU/hr CH input, 19,900 to 199,000 BTU/hr DHW input and 95% AFUE, recorded from the official LP-648 technical table.

Natural gasPropaneCombi

Compare models in this series

Comparison of HTP UFTC-140W and HTP UFTC-199W and HTP UFTC-140F and HTP UFTC-199F
SpecificationHTP UFTC-140WHTP UFTC-199WHTP UFTC-140FHTP UFTC-199F
Central-heating input, minimum14 MBH19.9 MBH14 MBH19.9 MBH
Central-heating input, maximum140 MBH140 MBH140 MBH140 MBH
output-max
AFUE96 %95 %96 %95 %
Turndown10:110:110:110:1
vent-max-3
vent-max-2
Weight, wall model110 lb120 lb140 lb150 lb

Read the full comparison: HTP UFTC-140W vs UFTC-199W

Read the full comparison: HTP UFTC-140F vs UFTC-199F

Read the full comparison: HTP UFTC-140F vs HTP UFTC-140W

Read the full comparison: HTP UFTC-140W vs HTP UFTC-199F

Error codes and alerts

UFT Combi (discontinued) alerts

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What UFT Combi models exist?

Four: UFTC-140W and UFTC-199W wall-mount and UFTC-140F and UFTC-199F floor-mount combined appliances.

Is the UFT Combi discontinued?

Yes — the official documents page states 'This products has been discontinued, please see the below documentation for support.' and the discontinued index lists the UFT Combi Boiler (Wall & Floor).

What is the difference between the 140 and 199 UFT Combi?

The 140 fires 14,000-140,000 BTU/hr for CH and DHW with 96% AFUE; the 199 fires 19,900-140,000 CH as shipped (increasable to 199,000 with a larger external pump) and 19,900-199,000 DHW with 95% AFUE, and delivers more hot water (9.9 vs 7.1 GPM at a 35°F rise).