IBC VX “Roll out switch” alert

Error – Roll Out Switch

SafetyIBC VX Series boilers with the V-10 touchscreen controller

The manual lists this alert when the rollout switch beside the combustion chamber detects 230°F, meaning flame or hot combustion gas is rolling out of the burner area instead of staying in the combustion chamber. The boiler locks out and the switch must be manually reset only after the cause is found.

Applies to

This alert is shown by the V-10 touchscreen controller on VX Series residential boilers (VX 110, VX 150 and VX 199), as documented in IBC Installation & Operating Manual — VX 110 / VX 150 / VX 199, doc 120-347E6, sections 9.2–9.4.

Controller: V-10 touchscreen controller. Source manual: 120-347E6 (2026-08-07).

Why a code is not a diagnosis

Rollout is a combustion-safety event. Common causes include a restricted flue passage, leaking lid/fan/ignitor gaskets, an obstructed heat exchanger, or improper combustion. The alert does not identify the cause, and the boiler must not simply be reset and run.

Safe things to observe

  • Treat this alert seriously: it means combustion gas did not go where it should.
  • If a carbon-monoxide alarm sounds, leave the building immediately and call 911 from outside.
  • Turn the boiler off at its service switch and call a licensed technician before running it again.
  • If you smell gas, leave and call FortisBC at 1-800-663-9911 or 911 first.

Do not

  • Do not reset the rollout switch yourself or run the boiler after a rollout event.
  • Do not operate the boiler until a technician has found and corrected the cause.

How professional service helps

  1. A technician inspects the burner lid, fan and ignitor gaskets and the flue passages for obstruction or leakage.
  2. Combustion is measured with an analyser and any gas-pressure or set-up faults are corrected.
  3. Only after the cause is fixed is the rollout switch safely reset and the boiler test-fired.

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Parts and service

Parts commonly involved

These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.

Service for this alert

  • Gas Boiler Repair

    Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…

  • Emergency Boiler Repair

    Priority gas boiler repair for homes and buildings in Greater Vancouver with no heat, no hot water, a locked-out boiler or a leak.

Every boiler part explained — what it does, how it fails and what a technician checks.

Documented for IBC Technologies VX Series.

Frequently asked questions

What is flame rollout?

Rollout is when flame or hot combustion gas escapes the burner chamber instead of passing through the heat exchanger. It can damage the boiler and is a CO risk, which is why the boiler locks out and needs a professional before it runs again.

Boiler locked out? Call with the alert text ready.

The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate