IBC VX 150
The IBC VX 150 is the mid-size VX Series boiler: 23 to 150 MBH input, 95% AFUE, wall-hung with the V-10 controller, 3" venting to 170 equivalent feet and a 2" option to 50 feet.
Key figures
- Max input
- 150 MBH
- Max CSA output
- 138.5 MBH
- AFUE
- 95 %
- Min input
- 23 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
IBC VX 150 in practice
The VX 150 fills the gap between the 110 and the 199 in IBC's compact VX range, with 150 MBH input and up to 138.5 MBH CSA output. Its 23 MBH minimum input is higher than the SL 20-160 G3's 20 MBH, so in a very mild shoulder season the larger minimum fire rate matters more than the top end.
Like every VX model it is heating-only with an indirect tank for domestic hot water, connected directly per IBC's documentation. The controller manages up to four heating zones plus the primary pump, and the VX line cascades to four boilers where a building grows later.
Venting is 3" Schedule 40 or PPs to 170 equivalent feet per side, with a 2" option limited to 50 feet. At 78 lb it is 11 lb heavier than the VX 110 but still well below the 152 lb SL 30-199 G3.
Best suited to
- Homes whose heat-loss calculation lands between the VX 110 and VX 199
- Detached houses with several zones managed from the boiler's built-in controls
- Projects that may later add a second boiler in cascade
Applicability and support
- Model number
- IBGFSW1-0150
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 23 MBH | 6.7 kW |
| Input, maximum | 150 MBH | 44 kW |
| Output | ||
| CSA output, minimum | 22 MBH | 6.5 kW |
| CSA output, maximum | 138.5 MBH | 40.6 kW. DOE heating capacity is not published on the IBC pages we cite. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | As published by IBC on the Canadian VX model page. |
| Domestic hot water | ||
| Domestic hot water | Not a combi; IBC documents direct connection of an indirect tank | |
| Venting and air | ||
| Flue material | 3" Schedule 40 or 3" PPs (80 mm); PVC/CPVC/PPs approved | |
| Max. equivalent vent length, 3" | 170 ft | Each side; see the installation manual for the equivalent-length method. |
| Max. equivalent vent length, 2" | 50 ft | |
| Air intake | Direct vent or indoor supply | |
| Physical and connections | ||
| Weight (empty) | 78 lb | 35.4 kg |
| Water connections | 1" NPT | |
| Gas connection | 1/2" NPT | |
| Condensate connection | 3/4" hose | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Conversion kit included per IBC model page. |
| Turndown ratio | up to 6.5:1 | |
| Gas supply pressure | 4 – 14 in. w.c. | |
| Max. operating pressure | 50 psig | Ships with a 30 psig relief valve. |
| Max. water temperature | 190 °F | Electronic limit. |
| Altitude rating | 0 – 12,000 ft | |
Manuals
Alerts documented for this model
- Error – Ignition trials exceeded
- Error – Water High-Limit
- Error – Low Water Cutoff
- Error: Interlock [1 or 2] Open
- Error: Vent High Limit
- Error – Max. delta T Exceeded
- Error – Low RPM / Air Flow
- Error – Fan Pressure
- Error – Module High Current
- Error – Low Module Current
- Error – Low Water Pressure
- Error – Inlet Pres. Sensor
- Error – See: Status > SIM menu > Status
- Error – Roll Out Switch
- Error – Controller Board
- Error – No Boilernet Comm
- Error – No MAC address
- Error – Flame Signal / Vent Block
- Error – Reversed Flow
- Error – Temp. probe error
- Error – Unhandled error code
- Outlet Limited
- Remote offline
- Unoccupied
- Summer
- Failsafe Setpoint
Frequently asked questions
Does the VX 150 allow 2" venting?
Yes, up to 50 equivalent feet per side in 2". In 3" the maximum is 170 equivalent feet per side.
What is the operating pressure rating of the VX 150?
IBC lists 50 psig maximum operating pressure for the VX 150, matching the VX 110; the VX 199 is rated 30 psig.
Is the VX 150 sold in Canada?
Yes. IBC Canada lists the VX 150 with CSA input and output figures. Whether ROMA supplies it is confirmed at consultation.
Questions about the IBC VX 150?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- IBC VX 110 / VX 150 / VX 199 — model page · accessed September 7, 2026
- IBC VX Series — series page · accessed September 7, 2026
- IBC VX Installation & Operating Manual · 120-347E6 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.