IBC VX 199
The IBC VX 199 is the largest VX Series boiler: 30.6 to 199 MBH input, 95% AFUE, 3" venting only to 100 equivalent feet, rated at 30 psig, and the lightest way IBC offers a 199 MBH wall-hung input at 88 lb.
Key figures
- Max input
- 199 MBH
- Max CSA output
- 183.7 MBH
- AFUE
- 95 %
- Min input
- 30.6 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
IBC VX 199 in practice
The VX 199 delivers up to 183.7 MBH CSA output from a boiler that weighs just 88 lb, which makes it a compact alternative to the 152 lb SL 30-199 G3 for large homes and small multi-suite buildings. It keeps the V-10 controller, built-in multi-zone outputs and cascade capability of the VX line.
The trade-off is venting: the VX 199 is 3" only, with 100 equivalent feet per side, and its maximum operating pressure is 30 psig rather than the 50 psig of the VX 110 and VX 150. Any plan should check the vent route against the 100-foot limit early, since a basement boiler far from an exterior wall may not fit the VX 199.
It is heating-only, with domestic hot water from an indirect tank connected directly to the boiler as IBC documents. Its 30.6 MBH minimum input is the highest in the VX line, so in a low-load home the larger boiler would cycle more in mild weather.
Best suited to
- Large homes and small multi-suite buildings needing up to about 184 MBH output
- Projects where a compact, relatively light 199 MBH wall-hung boiler is required
- Mechanical rooms within 100 equivalent feet of a vent terminal in 3" pipe
Applicability and support
- Model number
- IBGFSW1-0199
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 30.6 MBH | 8.8 kW |
| Input, maximum | 199 MBH | 58.3 kW |
| Output | ||
| CSA output, minimum | 29.2 MBH | 8.6 kW |
| CSA output, maximum | 183.7 MBH | 53.8 kW. DOE heating capacity is not published on the IBC pages we cite. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | As published by IBC on the Canadian VX model page. |
| Domestic hot water | ||
| Domestic hot water | Not a combi; IBC documents direct connection of an indirect tank | |
| Venting and air | ||
| Flue material | 3" Schedule 40 or 3" PPs (80 mm); PVC/CPVC/PPs approved | |
| Max. equivalent vent length, 3" | 100 ft | Each side; flexible PPs limited to 30 ft. See the installation manual for the equivalent-length method. |
| Air intake | Direct vent or indoor supply | |
| Physical and connections | ||
| Weight (empty) | 88 lb | 39.9 kg |
| Water connections | 1" NPT | |
| Gas connection | 1/2" NPT | |
| Condensate connection | 3/4" hose | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Conversion kit included per IBC model page. |
| Turndown ratio | up to 6.5:1 | |
| Gas supply pressure | 4 – 14 in. w.c. | |
| Max. operating pressure | 30 psig | |
| Max. water temperature | 190 °F | Electronic limit. |
| Altitude rating | 0 – 12,000 ft | |
Manuals
Alerts documented for this model
- Error – Ignition trials exceeded
- Error – Water High-Limit
- Error – Low Water Cutoff
- Error: Interlock [1 or 2] Open
- Error: Vent High Limit
- Error – Max. delta T Exceeded
- Error – Low RPM / Air Flow
- Error – Fan Pressure
- Error – Module High Current
- Error – Low Module Current
- Error – Low Water Pressure
- Error – Inlet Pres. Sensor
- Error – See: Status > SIM menu > Status
- Error – Roll Out Switch
- Error – Controller Board
- Error – No Boilernet Comm
- Error – No MAC address
- Error – Flame Signal / Vent Block
- Error – Reversed Flow
- Error – Temp. probe error
- Error – Unhandled error code
- Outlet Limited
- Remote offline
- Unoccupied
- Summer
- Failsafe Setpoint
Frequently asked questions
Can the VX 199 use 2" venting?
No. IBC lists 3" venting only for the VX 199, with a 100-foot maximum equivalent length per side.
How does the VX 199 compare to the SL 30-199 G3?
Both reach about 199 MBH input. The VX 199 weighs 88 lb versus 152 lb and cascades with other VX units, but its vent limit is 100 feet versus 150 feet on the SL, and its maximum operating pressure is 30 psig versus 30 psig on the SL (the VX 110 and 150 are rated 50 psig).
Is the VX 199 available in Canada?
Yes. IBC Canada lists the VX 199 with CSA input and output figures. Whether ROMA supplies it is confirmed at consultation.
Questions about the IBC VX 199?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- IBC VX 110 / VX 150 / VX 199 — model page · accessed September 7, 2026
- IBC VX Series — series page · accessed September 7, 2026
- IBC VX Installation & Operating Manual · 120-347E6 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.