The Ideal Exalt Floor 110 is the smallest floor-standing Exalt model: 13,750 to 110,000 BTU/h at 95% AFUE with an included Caleffi 548 separator, a pre-installed circulator and cascade control for up to six boilers.

CurrentCanadian status unknown

Key figures

Max input
110 MBH
Max CSA output
AFUE
95 %
Min input
13.75 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Ideal Exalt Floor 110 in practice

The Exalt Floor 110 takes the residential Exalt platform off the wall. Input runs 13,750 to 110,000 BTU/h at 95% AFUE with an 8:1 turndown, a 102 MBH DOE heating capacity and an 89 MBH AHRI net rating. The floor chassis adds equipment the wall models do not include: a Caleffi 548 series separator with air elimination and a pre-installed internal circulator, with water and gas connections available on either side.

The cabinet measures 22 x 41 x 22 inches and weighs 145 lb with 2 gallons of water volume; the separator outlet is 1-1/4-inch FPT when the Caleffi 548 is used. Venting is 2-inch up to 33 equivalent feet or 3-inch up to 100 feet through the 3-in-1 universal vent adapter, and the model supports an integrated cascade of up to six boilers. It is a heat-only model — domestic hot water comes from a separate source.

The CTRLMax control provides plain-text diagnostics, outdoor reset, DHW priority and configurable circulator outputs. The floor-standing format suits retrofits with mechanical-room floor space and systems that benefit from a factory-mounted separator and pump. Natural-gas (IDEXFS110S) and propane (IDEXFS110SLP) versions are published. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.

Best suited to

  • Retrofits with mechanical-room floor space instead of wall space
  • Systems that benefit from a factory-mounted separator and circulator
  • Small low-load buildings that may later cascade up to six boilers

Applicability and support

Model number
IDEXFS110S (NG) / IDEXFS110SLP (LP)
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.

Ideal Exalt Floor 110 specifications
SpecificationValueNote
Input
Input, minimum (NG & LP)13.75 MBH13,750 BTU/h per the official model table
Input, maximum (NG & LP)110 MBH110,000 BTU/h per the official model table
Output
DOE heating capacity102 MBHPer the official model table.
AHRI net rating89 MBHPer the official model table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the official model table.
Domestic hot water
Domestic hot waterHeating-only; pair with a separate DHW source
Venting and air
Vent / air connections3 in
Maximum vent length, 3 in100 ftPer the official model table.
Maximum vent length, 2 in33 ftPer the official model table.
Physical and connections
Weight145 lb
Width22 in
Height41 in
Depth22 in
Operating limits and other
Turndown ratio8:1Per the official model table.
Gas connection (MNPT)3/4 in
Supply / return connections (MNPT)1 in1-1/4 in FPT when using the Caleffi 548 separator.
Water volume2 galPer the official model table.
Integrated cascadeUp to 6 boilersPer the official model table.
Maximum CH flow temperature185 °F185°F (85°C) per the official model table.

Frequently asked questions

What is included with the Exalt Floor 110 that wall models do not have?

A Caleffi 548 series separator with air elimination and a pre-installed internal circulator, plus left-or-right water and gas connections, per the official model table.

What is the input range of the Exalt Floor 110?

13,750 to 110,000 BTU/h at 95% AFUE with an 8:1 turndown, a 102 MBH DOE heating capacity and an 89 MBH AHRI net rating.

Can the Exalt Floor 110 be cascaded?

Yes — the model table lists an integrated cascade function for up to six boilers, and the floor series shares the Exalt cascade wiring bulletin.

Questions about the Ideal Exalt Floor 110?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate