Ideal Heating · Exalt Floor (heat-only)

Ideal Exalt Floor 199

The Ideal Exalt Floor 199 is the largest floor-standing Exalt model: 24,875 to 199,000 BTU/h at 95% AFUE, 8:1 turndown and a 169 lb chassis with separator, circulator and six-boiler cascade capability.

CurrentCanadian status unknown

Key figures

Max input
199 MBH
Max CSA output
AFUE
95 %
Min input
24.875 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Ideal Exalt Floor 199 in practice

The Exalt Floor 199 tops the floor-standing Exalt range at 199,000 BTU/h input with a 24,875 BTU/h minimum, an 8:1 turndown, a 184 MBH DOE heating capacity and a 159 MBH AHRI net rating, all at 95% AFUE. It suits larger homes and small commercial loads that want the floor-standing format's included separator and pump.

The cabinet is 22 x 41 x 22 inches at 169 lb with 4 gallons of water volume, and the model ships with the Caleffi 548 series separator with air elimination and a pre-installed internal circulator. Venting is 3-inch up to 100 equivalent feet; the 2-inch option published for the smaller floor models does not appear on the 199 row. Connections are 3/4-inch gas and 1-inch supply/return (1-1/4-inch FPT with the separator).

The CTRLMax control carries the series' features — plain-text diagnostics, outdoor reset, DHW priority and configurable circulator outputs — and the integrated cascade function supports up to six boilers. As a heat-only model it needs a separate DHW source. Natural-gas (IDEXFS199S) and propane (IDEXFS199SLP) versions are published. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.

Best suited to

  • Larger homes and light-commercial loads up to 199 MBH wanting a floor-standing boiler
  • Plants planning a cascade of up to six Exalt Floor units
  • Installations that prefer factory-mounted separation and circulation

Applicability and support

Model number
IDEXFS199S (NG) / IDEXFS199SLP (LP)
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.

Ideal Exalt Floor 199 specifications
SpecificationValueNote
Input
Input, minimum (NG & LP)24.875 MBH24,875 BTU/h per the official model table
Input, maximum (NG & LP)199 MBH199,000 BTU/h per the official model table
Output
DOE heating capacity184 MBHPer the official model table.
AHRI net rating159 MBHPer the official model table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the official model table.
Domestic hot water
Domestic hot waterHeating-only; pair with a separate DHW source
Venting and air
Vent / air connections3 in
Maximum vent length, 3 in100 ftPer the official model table.
Physical and connections
Weight169 lb
Width22 in
Height41 in
Depth22 in
Operating limits and other
Turndown ratio8:1Per the official model table.
Gas connection (MNPT)3/4 in
Supply / return connections (MNPT)1 in1-1/4 in FPT when using the Caleffi 548 separator.
Water volume4 galPer the official model table.
Integrated cascadeUp to 6 boilersPer the official model table.
Maximum CH flow temperature185 °F185°F (85°C) per the official model table.

Frequently asked questions

What is the input range of the Exalt Floor 199?

24,875 to 199,000 BTU/h at 95% AFUE with an 8:1 turndown, a 184 MBH DOE heating capacity and a 159 MBH AHRI net rating.

Does the Exalt Floor 199 list a 2-inch vent option?

No. The official model table lists 3-inch venting up to 100 equivalent feet for the 199; 2-inch venting appears on the 110 and 155 floor rows.

How much does the Exalt Floor 199 weigh?

169 lb in a 22 x 41 x 22 inch cabinet, with 4 gallons of water volume, per the official model table.

Questions about the Ideal Exalt Floor 199?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate