The Gallant Wall is Ideal Heating North America's larger wall-hung condensing boiler line for residential and light-commercial loads: the 250, 299 and 399 MBH heat-only models, up to 5.5:1 turndown, ASME-certified with an integrated cascade function for up to six boilers.

Current seriesunknownNatural gasPropaneresidentialcommercial

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas or propane; each size ships in fuel-specific versions (IDGA250 / IDGA250LP, IDGA299 / IDGA299LP, IDGA399 / IDGA399LP).
Venting
3-inch vent/air on the 250 and 4-inch on the 299 and 399. A vent supplement is published for the series.
Models documented
3

95% AFUE on the 250 and 299; the 399 prints 95.1%, which the page footnotes as thermal efficiency.

About the Gallant Wall

The Gallant Wall line sits above the Exalt series in capacity: three heat-only wall-hung condensing models — 250, 299 and 399 MBH — with published input modulation ranges of 53.6–240 MBH (250), 72.5–299 MBH (299) and 72.5–399 MBH (399). The page prints 95% AFUE for the 250 and 299 and 95.1% for the 399, footnoted as thermal efficiency, with AHRI net ratings of 192, 242 and 330 MBH and DOE heating capacities of 222, 278 and 379 MBH.

The series uses a stainless steel fire-tube heat exchanger with full modulation and turndown ratios of 5.5:1 (250), 4.1:1 (299) and 5.5:1 (399). The CTRLMax control system is described as configurable in 60 seconds or less for standard installations, with four fully configurable circulator outputs, two reset curves and set points, quiet operation and an integrated cascade function for up to six boilers. The 250 is a 3-inch vent model at 140 lb with 3/4-inch gas and 1-1/4-inch supply/return connections; the 299 and 399 step up to 4-inch venting, 1-inch gas and 1-1/2-inch water connections at 210 and 216 lb.

Both sizes list natural-gas and propane versions (IDGA250 / IDGA250LP and so on), ASME certification and ENERGY STAR listing. For BC projects the Gallant Wall line covers larger homes and small commercial plants that still want a wall-hung boiler, and the published engineering submittals and installation manual document the series for specification work. As with the rest of the North American catalogue, canadianStatus is recorded as unknown because no explicit Canadian sales statement was found on the official pages checked on 2026-09-09.

Highlights

  • 250, 299 and 399 MBH wall-hung heat-only models
  • 95% AFUE (250, 299); the 399 prints 95.1% as thermal efficiency
  • Up to 5.5:1 turndown; stainless steel fire-tube heat exchanger
  • ASME certified and ENERGY STAR listed
  • Integrated cascade function for up to six boilers
  • Fully configurable four circulator outputs on CTRLMax

Ideal Advantage warranty program, as published on the Exalt product pages: Standard — 2-year parts and 10-year primary heat exchanger; Plus — 5-year parts, 2-year labour allowance and 10-year primary heat exchanger with registration; Elite — 6-year parts, 3-year labour and 12-year heat exchanger with registration, combustion analysis and hydronic system treatment.

Models

Gallant Wall models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
53.6–240 MBH
Output (max)
AFUE
95 %

The Ideal Gallant Wall 250 is the smallest Gallant model: 53.6 to 240 MBH input at 95% AFUE, 5.5:1 turndown and a 140 lb wall-hung cabinet with 3-inch venting and an integrated six-boiler cascade function.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
72.5–299 MBH
Output (max)
AFUE
95 %

The Ideal Gallant Wall 299 is the mid-size Gallant model: 72.5 to 299 MBH input at 95% AFUE with a 4.1:1 turndown, stepping up to the larger 210 lb chassis with 4-inch venting and 1-inch gas.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
72.5–399 MBH
Output (max)
AFUE
95.1 %

The Ideal Gallant Wall 399 is the largest Gallant model: 72.5 to 399 MBH input with a 5.5:1 turndown, a 330 MBH AHRI net rating and a printed 95.1% figure the page footnotes as thermal efficiency.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Ideal Gallant Wall 250 and Ideal Gallant Wall 299 and Ideal Gallant Wall 399
SpecificationIdeal Gallant Wall 250Ideal Gallant Wall 299Ideal Gallant Wall 399
Input modulation, minimum (NG & LP)53.6 MBH72.5 MBH72.5 MBH
Input modulation, maximum (NG & LP)240 MBH299 MBH399 MBH
output-max
Efficiency95 %95 %95.1 %
Turndown ratio5.5:14.1:15.5:1
vent-max-3
vent-max-2
Weight140 lb210 lb216 lb

Read the full comparison: Ideal Gallant Wall 250 vs 299

Read the full comparison: Ideal Gallant Wall 299 vs 399

Read the full comparison: Ideal Gallant Wall 250 vs Wall 399

Error codes and alerts

Gallant Wall alerts

  • E1CTRLMax control (E-code lockout display)
  • E2CTRLMax control (E-code lockout display)
  • E3CTRLMax control (E-code lockout display)
  • E5CTRLMax control (E-code lockout display)
  • E8CTRLMax control (E-code lockout display)
  • E9CTRLMax control (E-code lockout display)
  • E13CTRLMax control (E-code lockout display)
  • E15CTRLMax control (E-code lockout display)
  • E16CTRLMax control (E-code lockout display)
  • E17CTRLMax control (E-code lockout display)
  • E18CTRLMax control (E-code lockout display)
  • E19CTRLMax control (E-code lockout display)
  • E21CTRLMax control (E-code lockout display)
  • E30CTRLMax control (E-code lockout display)
  • E31CTRLMax control (E-code lockout display)
  • E43CTRLMax control (E-code lockout display)
  • E44CTRLMax control (E-code lockout display)
  • E47CTRLMax control (E-code lockout display)
  • E80CTRLMax control (E-code lockout display)
  • E83CTRLMax control (E-code lockout display)
  • E84CTRLMax control (E-code lockout display)
  • E87CTRLMax control (E-code lockout display)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What is the input range of each Gallant Wall model?

The published modulation ranges are 53.6 to 240 MBH for the 250, 72.5 to 299 MBH for the 299 and 72.5 to 399 MBH for the 399, with AHRI net ratings of 192, 242 and 330 MBH respectively.

Can Gallant Wall boilers be cascaded?

Yes. The series lists an integrated cascade function for up to six boilers, and the separate Gallant Cascade rack packages join 2 to 5 boilers for total inputs of 500 to 2,000 MBH.

Which Gallant size uses 4-inch venting?

The 299 and 399 use 4-inch vent/air connections; the 250 uses 3-inch. The series also has a published vent supplement with the detailed installation requirements.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.