Navien NCB-240/130H
The Navien NCB-240/130H is the 240-class NCB-H combi with 13 to 130 MBH heating input, DHW input to 199,900 BTU/h, 95.0% AFUE and a 96 lb cabinet — headroom for larger homes with radiators or in-floor heat.
Key figures
- Max input
- 130 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 13 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Navien NCB-240/130H in practice
The NCB-240/130H lifts the heating ceiling of the 240-class cabinet from 110 to 130 MBH while the DHW side stays at 13,300 to 199,900 BTU/h. Homes with cast-iron radiators, several zones or an add-on load are where the extra 20 MBH matters, and the 13 MBH minimum fire keeps shoulder-season modulation intact.
It keeps the same dimensions as the rest of the NCB-H line — 17.3 x 29.3 x 12.8 in at 96 lb — with the dual stainless heat exchanger arrangement, 95.0% AFUE rating and 1" NPT heating connections. Venting remains 2" or 3" PVC, CPVC or approved polypropylene to 65 or 150 equivalent feet per the installation manual.
Best suited to
- Larger detached homes whose heat-loss calculation exceeds 110 MBH
- Homes with radiators or several heating zones needing 130 MBH of ceiling
- Households that want 240-class DHW range without stepping up to the NCB-250
Applicability and support
- Model number
- NCB-240/130H
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Navien. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 13 MBH | Space-heating input. |
| Heating input, maximum | 130 MBH | Space-heating input. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the installation manual. |
| Domestic hot water | ||
| DHW input, minimum | 13.3 MBH | 13,300 BTU/h |
| DHW input, maximum | 199.9 MBH | 199,900 BTU/h |
| Domestic hot water | Integrated in the combi heat exchanger | |
| Venting and air | ||
| Venting | PVC, CPVC or approved polypropylene; 2" or 3" | Canada: plastic venting must meet ULC S636 where required. |
| Max. equivalent vent length, 2" | 65 ft | |
| Max. equivalent vent length, 3" | 150 ft | |
| Physical and connections | ||
| Weight | 96 lb | Empty; per the installation manual. |
| Width | 17.3 in | |
| Height | 29.3 in | |
| Depth | 12.8 in | |
| Gas connection | 3/4" NPT | |
| Heating water connections | 1" NPT | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Separate Navien ratings per fuel. |
| Altitude rating | 10,100 ft | Per installation manual. |
| System water pressure | 12 – 30 psi | |
Manuals
Alerts documented for this model
Frequently asked questions
What is the input range of the NCB-240/130H?
13,000 to 130,000 BTU/h for space heating and 13,300 to 199,900 BTU/h for domestic hot water, per the installation manual, at 95.0% AFUE.
Is the NCB-240/130H the same size as the NCB-240/110H?
Yes. Both are 17.3 x 29.3 x 12.8 in and weigh 96 lb; only the maximum heating input differs (130 MBH versus 110 MBH).
Does the NCB-240/130H need a hot-water tank?
No. It is a combi: the built-in DHW module produces domestic hot water on demand, so no separate tank is required.
Questions about the Navien NCB-240/130H?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Navien Canada — NCB-H series · accessed September 7, 2026
- NCB-H Installation and Operation Manual (EN) · accessed September 7, 2026
- NCB-H Service Manual, Ver 1.00 (Feb 2021) · Ver 1.00 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.