New Yorker GHE-II Combi E15 — Air Proving Switch (aps) Defective (failed to Open)
E15
Air Proving Switch (APS) Defective (failed to open). The air proving switch failed to open: its contact is closed when it should be open, the blower is running before the start sequence or communication between the control and blower is lost, or airflow is blocked, which locks the boiler out. The table classifies it as Lockout.
Applies to
This venting or air-supply fault code is displayed by the GHE-II Combi control (H hold/warning and E lockout codes) on GHE-II Combi models (GHE2C-136B, GHE2C-200), as documented in GHE-II High Efficiency Combi Boiler — Installation, Operating & Service Instructions (English), doc 110329-10 (11/25), Section 19 Table 19-5 (110329-10). Codes can differ between controller generations, so always check the manual that matches your unit.
Controller: GHE-II Combi control (H hold/warning and E lockout codes). Source manual: 110329-10 (2025-11).
Why a code is not a diagnosis
A venting or air-supply code points at the combustion-air path: a blocked terminal, a restricted flue, a failed fan, or a condensate restriction. It does not say which, and running an appliance with a blocked flue is unsafe.
Safe things to observe
- If a carbon-monoxide alarm sounds anywhere in the building, leave immediately and call 911 from outside.
- From a safe distance, check that the vent terminal and combustion-air inlet are not blocked.
- Do not run the appliance while a blockage is suspected.
Do not
- Do not put anything into the vent or air-intake openings.
- Do not remove or modify vent pipe.
How professional service helps
- A technician inspects the full vent and combustion-air path, clears blockages and checks the fan.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Combustion fan (blower)
The combustion fan is the sealed boiler's lungs: it draws in combustion air, keeps the burner's gas-air mixture correct, and pushes flue gases out…
What a technician checks →Air pressure switch
An air pressure switch proves that the combustion fan is moving air and that the vent path is clear before the boiler is allowed to fire.
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
- Emergency Boiler Repair
Priority gas boiler repair for homes and buildings in Greater Vancouver with no heat, no hot water, a locked-out boiler or a leak.
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for New Yorker Boiler GHE-II Combi.
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- GHE-II High Efficiency Combi Boiler — Installation, Operating & Service Instructions (English), doc 110329-10 (11/25), Section 19 Table 19-5 · 110329-10 · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.