Skip to content
Boilers.caby ROMA Heating & Cooling

New Yorker Boiler · Series

New Yorker Boiler GHE-II Combi

The New Yorker GHE-II Combi is the condensing combination version of the GHE-II: models GHE2C-136B (13.6–120 MBH heating input, DHW to 136 MBH, 3.7 GPM at a 70°F rise) and GHE2C-200 (20–150 MBH heating, DHW to 200 MBH, 5.2 GPM), both 95.0% AFUE with a flat-plate DHW heat exchanger and 10:1 DHW turndown.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
95% AFUE
Fuel
Natural gas / Propane
Venting
Direct vent, sealed combustion on a 2" vent and air-intake connection, with horizontal and vertical two-pipe, concentric, low-profile and hybrid configurations per the data sheet.
Models documented
2

Both combi rows print 95.0% AFUE in the GHE-II data sheet ratings table.

About the GHE-II Combi

The GHE-II Combi is New Yorker's condensing combination boiler, published on the official site under Condensing Gas with 95% AFUE and a 'Just hang and heat' positioning. The product page and data sheet describe an integrated hydro block system with a flat-plate heat exchanger, boiler circulator and three-way valve, a pre-made primary/secondary manifold included with combi models, virtually instantaneous DHW response, DHW recirculation mode, DHW temperature maintained under all conditions, 10:1 DHW turndown, and the same 316L stainless-steel boiler-side heat exchanger, automatic no-touch combustion management and sensor-less rate-based reset as the heating-only GHE-II.

The GHE-II data sheet prints two combi rating rows: GHE2C-136B (13.6–120 MBH heating input, 113 MBH DOE heating capacity, 98 MBH net AHRI, 3.7 GPM at a 70°F rise / 3.4 GPM at 77°F, DHW input 13.6–136 MBH, 2" vent, 95 lb, 16.3" deep) and GHE2C-200 (20–150 MBH heating, 141/123 MBH, 5.2/4.7 GPM, DHW input 20.0–200 MBH, 2", 116 lb, 20.4"). Both rows print 95.0% AFUE. Combi models use a Grundfos UPS-78 Special circulator, include the primary/secondary header with 1-1/4-inch sweat connections, and carry a thermostatic mixing valve and recirculation/header sensor among the listed accessories. Performance is shown for elevations to 2,000 feet, with 'G00' SKUs covering altitudes to 10,100 feet.

Boilers.ca documents both combi sizes at model level from the data sheet and links the published combi I&O manual. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Highlights

  • Current New Yorker condensing combi: GHE2C-136B and GHE2C-200
  • 95.0% AFUE on both rows; heating input 13.6–120 and 20–150 MBH
  • DHW firing to 136 and 200 MBH with 10:1 DHW turndown
  • DHW delivery 3.7 GPM and 5.2 GPM at a 70°F rise (3.4/4.7 at 77°F)
  • Integrated hydro block with flat-plate heat exchanger and 3-way valve
  • Primary/secondary manifold included on combi models
  • Model-level pages published on Boilers.ca; data sheet and combi I&O manual linked here

Five-year parts warranty with a 12-year limited heat exchanger warranty per the GHE-II data sheet.

Models

GHE-II Combi models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II Combi GHE2C-136B is the smaller combi with 3.7 GPM DHW delivery at a 70°F rise: space heating at 13.6–120 MBH input with a DHW side firing 13.6–136 MBH at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II Combi GHE2C-200 is the larger combi with 5.2 GPM DHW delivery at a 70°F rise: space heating at 20–150 MBH input with a DHW side firing 20–200 MBH at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneCombi

Compare models in this series

Comparison of New Yorker GHE-II Combi GHE2C-136B and New Yorker GHE-II Combi GHE2C-200
SpecificationNew Yorker GHE-II Combi GHE2C-136BNew Yorker GHE-II Combi GHE2C-200
Heating input, minimum13.6 MBH20 MBH
Heating input, maximum120 MBH150 MBH
output-max——
Efficiency (AFUE)95 %95 %
turndown——
vent-max-3——
vent-max-2——
Boiler weight95 lb116 lb

Read the full comparison: New Yorker GHE-II Combi GHE2C-136B vs GHE2C-200 →

Error codes and alerts

GHE-II Combi alerts

  • H01GHE-II Combi control (H hold/warning and E lockout codes)
  • H02GHE-II Combi control (H hold/warning and E lockout codes)
  • H04GHE-II Combi control (H hold/warning and E lockout codes)
  • E04GHE-II Combi control (H hold/warning and E lockout codes)
  • H05GHE-II Combi control (H hold/warning and E lockout codes)
  • E05GHE-II Combi control (H hold/warning and E lockout codes)
  • H06GHE-II Combi control (H hold/warning and E lockout codes)
  • E06GHE-II Combi control (H hold/warning and E lockout codes)
  • H07GHE-II Combi control (H hold/warning and E lockout codes)
  • E07GHE-II Combi control (H hold/warning and E lockout codes)
  • H08GHE-II Combi control (H hold/warning and E lockout codes)
  • H09GHE-II Combi control (H hold/warning and E lockout codes)
  • E09GHE-II Combi control (H hold/warning and E lockout codes)
  • H10GHE-II Combi control (H hold/warning and E lockout codes)
  • H11GHE-II Combi control (H hold/warning and E lockout codes)
  • E11GHE-II Combi control (H hold/warning and E lockout codes)
  • H12GHE-II Combi control (H hold/warning and E lockout codes)
  • H13GHE-II Combi control (H hold/warning and E lockout codes)
  • H14GHE-II Combi control (H hold/warning and E lockout codes)
  • E15GHE-II Combi control (H hold/warning and E lockout codes)
  • H16GHE-II Combi control (H hold/warning and E lockout codes)
  • E16GHE-II Combi control (H hold/warning and E lockout codes)
  • H17GHE-II Combi control (H hold/warning and E lockout codes)
  • E17GHE-II Combi control (H hold/warning and E lockout codes)
  • H18GHE-II Combi control (H hold/warning and E lockout codes)
  • E18GHE-II Combi control (H hold/warning and E lockout codes)
  • E19GHE-II Combi control (H hold/warning and E lockout codes)
  • H20GHE-II Combi control (H hold/warning and E lockout codes)
  • E20GHE-II Combi control (H hold/warning and E lockout codes)
  • H21GHE-II Combi control (H hold/warning and E lockout codes)
  • E21GHE-II Combi control (H hold/warning and E lockout codes)
  • H22GHE-II Combi control (H hold/warning and E lockout codes)
  • E22GHE-II Combi control (H hold/warning and E lockout codes)
  • H23GHE-II Combi control (H hold/warning and E lockout codes)
  • E23GHE-II Combi control (H hold/warning and E lockout codes)
  • H24GHE-II Combi control (H hold/warning and E lockout codes)
  • E24GHE-II Combi control (H hold/warning and E lockout codes)
  • H25GHE-II Combi control (H hold/warning and E lockout codes)
  • E25GHE-II Combi control (H hold/warning and E lockout codes)
  • H26GHE-II Combi control (H hold/warning and E lockout codes)
  • E26GHE-II Combi control (H hold/warning and E lockout codes)
  • H27GHE-II Combi control (H hold/warning and E lockout codes)
  • H28GHE-II Combi control (H hold/warning and E lockout codes)
  • E29GHE-II Combi control (H hold/warning and E lockout codes)
  • H30GHE-II Combi control (H hold/warning and E lockout codes)
  • H31GHE-II Combi control (H hold/warning and E lockout codes)
  • H32GHE-II Combi control (H hold/warning and E lockout codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What is the difference between the two GHE-II Combi sizes?

The GHE2C-136B covers 13.6–120 MBH heating input with DHW firing to 136 MBH and 3.7 GPM at a 70°F rise; the GHE2C-200 covers 20–150 MBH heating with DHW to 200 MBH and 5.2 GPM, in a deeper 20.4-inch cabinet at 116 lb.

Does the GHE-II Combi include the primary/secondary manifold?

Yes — the data sheet lists a pre-made primary/secondary manifold as included on combi models and as an accessory kit for heating-only models.

Is the GHE-II Combi available in Canada?

No official Canadian-sales statement was found on the official pages reviewed on September 9, 2026, so canadianStatus is recorded 'unknown'.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate