NTI Compass NC199C
The NTI Compass NC199C is the flagship floor-standing Compass combi: space heating at 19.9 to 199 MBH input with 4.8 GPM continuous DHW at a 77°F rise, rated 95% AFUE in a 215 lb floor cabinet.
Key figures
- Max input
- 199 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 19.9 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Compass NC199C in practice
The NC199C is the largest Compass and the line's only combi at the 199 MBH mark: heating input up to 199 MBH plus a domestic hot water function rated for 4.8 GPM continuous at a 77°F rise, in the 215 lb floor cabinet. Its DHW rating is the strongest of the Compass combis and the practical reason most homes choose it over the NC150C.
Like every Compass model it is floor-standing with reversible connections, and its venting stays on the simple 2"-to-100 ft / 3"-to-150 ft terms shared across the series. The 19.9 MBH minimum fire remains the caveat: this size earns its place through a genuine heat-loss and DHW calculation for a larger home, not through spare-capacity thinking.
Best suited to
- Larger homes wanting 199 MBH of heat plus high-volume DHW from one floor appliance
- Households whose simultaneous DHW draws exceed the NC150C's 3.6 GPM
- Floor-footprint replacements where boiler and tank consolidate into one unit
Applicability and support
- Model number
- NC199C
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Space-heating input, minimum | 19.9 MBH | Per the NTI product page. |
| Space-heating input, maximum | 199 MBH | Per the NTI product page. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | DOE AFUE per the NTI product page. |
| Domestic hot water | ||
| DHW capacity at 77°F rise | 4.8 GPM | Continuous delivery per the NTI product page. |
| Domestic hot water | Integrated combi (DHW plate) in the appliance | |
| Venting and air | ||
| Max. equivalent vent length, 2" | 100 ft | Each side per the I&O manual. |
| Max. equivalent vent length, 3" | 150 ft | Each side per the I&O manual. |
| Physical and connections | ||
| Weight | 215 lb | Per the NTI product page. |
| CH water connections | 1 1/4" NPT | Male NPT per the NTI product page. |
| DHW connections | 3/4" NPT | Male NPT per the NTI product page. |
| Gas connection | 3/4" NPT | Male NPT per the NTI product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for this series. |
| Turndown ratio | up to 10:1 | Manufacturer marketing figure on the NTI product page. |
Manuals
- Compass I&O Manual, 420011304100, Rev 04 (20240404)420011304100 Rev 04 · 2024-04-04
Alerts documented for this model
Frequently asked questions
How much hot water does the NC199C deliver?
4.8 GPM continuous at a 77°F rise per the NTI product page — the highest DHW rating in the Compass line.
Is the NC199C just the NC199 with DHW?
Both heat at 19.9 to 199 MBH at 95% AFUE. The combi NC199C weighs 215 lb against the NC199's 214 lb and adds the DHW function and 3/4" NPT DHW connections.
Does the NC199C suit an average-sized house?
Usually not. Its 19.9 MBH minimum fire is high for small loads, so the heat-loss and hot-water calculations should both justify the 199 MBH size before choosing it.
Questions about the NTI Compass NC199C?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- NTI — NTI Compass Series product page · accessed September 7, 2026
- Compass I&O Manual, 420011304100, Rev 04 (20240404) · 420011304100 Rev 04 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.