Skip to content
Boilers.caby ROMA Heating & Cooling

NTI Boilers · Series

NTI Boilers NTI Compass

The NTI Compass is a floor-standing residential condensing boiler line — NC085 through NC199 plus the NC110C, NC150C and NC199C combis — built as a floor cabinet around the FTVN-class control and electronics, with NTI marketing a limited lifetime heat-exchanger warranty.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
96% AFUE
Fuel
Natural gas or propane; NTI publishes LP conversion instructions for the Compass series (shared with the FTVN Series II).
Venting
2" runs up to 100 ft and 3" runs up to 150 ft across the series, per the NTI Compass product page.
Models documented
7

The page headline says "up to 96% AFUE": the DOE AFUE table rates the NC085 at 96% and the other Compass models at 95%.

About the NTI Compass

NTI builds the Compass for boiler replacements in older homes: a floor-standing cabinet that drops into an existing footprint without wall construction or stands, with left- or right-hand piping connections, an integrated ECM pump with primary/secondary piping, and a startup wizard on the FTVN-class control. The spec table is the floor version of the FTVN Series II profile: the NC085 through NC199 heating models and the NC110C, NC150C and NC199C combis, all with 1 1/4" NPT CH connections and 3/4" NPT gas.

The published profile matches the FTVN Series II rows: space-heating inputs from 8.5–85 MBH on the NC085 up to 19.9–199 MBH on the NC199, the same 2.7 / 3.6 / 4.8 GPM continuous DHW at a 77°F rise on the combis, and DOE AFUE of 96% on the NC085 with 95% on the other models. What changes is weight: the floor cabinet weighs 193 to 215 lb depending on the model.

The series page markets a stainless steel fire-tube heat exchanger with brass internal components, up to 96% AFUE, 10:1 modulation and a limited lifetime heat exchanger warranty, and the manual's display codes follow the FTVN-class numeric groups. For a Lower Mainland home replacing a floor-mounted boiler, the Compass avoids the wall-structure and re-piping work a wall-hung swap can create.

Highlights

  • Floor-standing residential condensing boiler, NC085–NC199 plus combis
  • Drops into an existing floor-mounted footprint; left- or right-hand connections
  • Same electrical and spec profile as the FTVN Series II rows
  • 96% AFUE (NC085), 95% on the other models
  • Stainless steel fire-tube heat exchanger with brass internal components
  • Limited lifetime heat-exchanger warranty claim on the NTI Compass page

The NTI Compass product page states the series is "backed by a limited lifetime heat exchanger warranty"; NTI publishes the warranty terms and registration through its warranty downloads.

Models

NTI Compass models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
8.5–85 MBH
Output (max)
—
AFUE
96 %

The NTI Compass NC085 is the smallest floor-standing Compass: 8.5 to 85 MBH input, the only Compass rated 96% AFUE, in a 193 lb floor cabinet designed to drop into an existing boiler footprint.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
—
AFUE
95 %

The NTI Compass NC110 is the 95% AFUE floor-standing Compass at 11 to 110 MBH input — the same 193 lb cabinet as the NC085 with 25 MBH more ceiling for detached homes with an indirect tank.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
15–150 MBH
Output (max)
—
AFUE
95 %

The NTI Compass NC150 is the 95% AFUE floor-standing Compass for mid-to-larger homes: 15 to 150 MBH input in a 203 lb floor cabinet with the platform's reversible connections and integrated pump package.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
—
AFUE
95 %

The NTI Compass NC199 is the largest heating-only Compass: 19.9 to 199 MBH input at 95% AFUE in a 214 lb floor cabinet — the floor-standing option for large homes that would otherwise need a wall-hung 199.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
—
AFUE
95 %

The NTI Compass NC110C is the smallest floor-standing Compass combi: space heating at 11 to 110 MBH input plus 2.7 GPM continuous DHW at a 77°F rise, rated 95% AFUE in a 194 lb floor cabinet.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–150 MBH
Output (max)
—
AFUE
95 %

The NTI Compass NC150C is the mid-size floor-standing Compass combi: space heating from 15 to 150 MBH input plus 3.6 GPM continuous DHW at a 77°F rise, rated 95% AFUE in a 204 lb floor cabinet.

Natural gasPropaneCombi
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
—
AFUE
95 %

The NTI Compass NC199C is the flagship floor-standing Compass combi: space heating at 19.9 to 199 MBH input with 4.8 GPM continuous DHW at a 77°F rise, rated 95% AFUE in a 215 lb floor cabinet.

Natural gasPropaneCombi

Compare models in this series

Comparison of NTI Compass NC085 and NTI Compass NC110 and NTI Compass NC150 and NTI Compass NC199 and NTI Compass NC110C and NTI Compass NC150C and NTI Compass NC199C
SpecificationNTI Compass NC085NTI Compass NC110NTI Compass NC150NTI Compass NC199NTI Compass NC110CNTI Compass NC150CNTI Compass NC199C
Input, minimum8.5 MBH11 MBH15 MBH19.9 MBH11 MBH15 MBH19.9 MBH
Input, maximum85 MBH110 MBH150 MBH199 MBH110 MBH150 MBH199 MBH
output-max———————
Efficiency (AFUE)96 %95 %95 %95 %95 %95 %95 %
Turndown ratioup to 10:1up to 10:1up to 10:1up to 10:1up to 10:1up to 10:1up to 10:1
Max. equivalent vent length, 3"150 ft150 ft150 ft150 ft150 ft150 ft150 ft
Max. equivalent vent length, 2"100 ft100 ft100 ft100 ft100 ft100 ft100 ft
Weight193 lb193 lb203 lb214 lb194 lb204 lb215 lb

Read the full comparison: NTI Compass NC085 vs NC110 →

Read the full comparison: NTI Compass NC110 vs NC150 →

Read the full comparison: NTI Compass NC150 vs NC199 →

Read the full comparison: NTI Compass NC110C vs NC150C →

Read the full comparison: NTI Compass NC150C vs NC199C →

Error codes and alerts

NTI Compass alerts

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the NTI Compass a combi boiler?

The Compass line includes both: the NC085–NC199 are heating-only, while the NC110C, NC150C and NC199C add domestic hot water from a single unit without a separate tank. NTI rates the combis' continuous DHW at 2.7, 3.6 and 4.8 GPM at a 77°F rise.

How does the Compass compare with the FTVN Series II?

The spec tables match — same inputs, AFUE ratings, DHW flows and venting terms — but the Compass is a floor-standing cabinet at 193–215 lb instead of a wall-hung boiler, with reversible connections and primary/secondary piping built in.

What warranty does the Compass carry?

The NTI Compass product page says the series is backed by a limited lifetime heat exchanger warranty. Boilers.ca does not restate the terms; NTI's warranty download and product registration set them out.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate