Peerless PureFire PF-210

The Peerless PureFire PF-210 fires 42 to 210 MBH input with 195 MBH heating capacity and a 170 MBH net water rating at 95.1% AFUE — the largest residential AFUE row — 42–210 MBH at 95.1% AFUE, alongside (not merged with) the PF-200 — on the stainless-steel, sealed-combustion direct-vent condensing platform.

CurrentCanadian status unknown

Key figures

Max input
210 MBH
Max CSA output
—
AFUE
95.1 %
Min input
42 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Peerless PureFire PF-210 in practice

The PureFire PF-210 is a stainless-steel, condensing, sealed-combustion direct-vent gas boiler rated at 42–210 MBH input. Its rating row prints 195 MBH heating capacity and a 170 MBH net water rating (1.15 piping and pickup allowance) at 95.1% AFUE in I&O manual Table 12.2 (PF8248-R9) and the residential cut sheet (CUT-PF R11).

The boiler ships in a 21" × 24" × 48" carton at about 165 lb, measures 16-3/4" × 17-3/16" × 40-1/2" (A × B × C) per the dimension table, connects on 1" NPT supply/return with 3/4" NPT gas, and runs on 120 VAC/60 Hz. Venting is 3" exhaust/air intake (PVC, CPVC, AL29-4C stainless or polypropylene) to a 200-equivalent-foot maximum combined length. The PureFire control shows status in plain English on an LCD, ignition is direct spark, and the product page claims ENERGY STAR certification (the PF-300 excepted) with a 12-year heat exchanger warranty.

Boilers.ca documents this size at model level for service planning and cross-referencing; installation, gas, electrical and venting work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 42-to-210 MBH residential heat-loss loads
  • Homes pairing the boiler with an indirect water heater for domestic hot water
  • Buyers comparing the PureFire residential sizes on the shared cut sheet

Applicability and support

Model number
PF-210
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Peerless Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

Peerless PureFire PF-210 specifications
SpecificationValueNote
Input
Input, minimum42 MBHMinimum input per the PureFire ratings table (I&O manual Table 12.2; residential cut sheet).
Input, maximum210 MBHMaximum input per the PureFire ratings table (I&O manual Table 12.2; residential cut sheet). Above 2,000 ft the boiler de-rates 3.5% per additional 1,000 ft with no adjustment to the boiler.
Output
Heating capacity195 MBHHeating capacity per the residential PureFire ratings table (I&O manual Table 12.2).
Net water rating170 MBHNet water rating based on a piping and pickup allowance of 1.15 per the PureFire ratings table (I&O manual Table 12.2).
Efficiency
Efficiency (AFUE)95.1 %AFUE per the PureFire ratings table (I&O manual Table 12.2; cut sheet).
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Exhaust vent / air intake3"Exhaust vent and air intake size per I&O manual Table 3.2; total combined exhaust and air-intake length to 200 equivalent feet (Table 3.3/3.4 notes). The exhaust connection is a 3" CPVC female adapter on PF-50–PF-140, and 3" (PF-200/PF-210) or 4" (PF-300/PF-399) male CPVC pipe per Section 3.E.
Approved vent materialsPVC, CPVC, AL29-4C stainless or polypropylene (Category IV, positive pressure)Approved exhaust vent materials per I&O manual Table 3.1; Canadian installations require ULC S636 venting.
Physical and connections
Approx. shipping weight165 lbApproximate carton shipping weight per the cut-sheet table (carton dimensions 21" × 24" × 48").
Dimensions (A × B × C)16-3/4" × 17-3/16" × 40-1/2"Boiler dimensions A, B and C per the I&O manual dimension table (Table 12.1).
Supply/return connections1" NPTSupply and return connection size per the I&O manual parts/dimension data (brass field couplings sized 1" NPT).
Gas connection3/4" NPTGas connection per the I&O manual (1/2" NPT manual shut-off valve listed for PF-50–PF-140; 3/4" flexible gas line and 3/4" NPT full-port shut-off valve listed for PF-200–PF-399).
Electrical
Electrical120 VAC, 60 Hz; max total service current to boiler 22.67 ASupply 120 VAC (-15%, +10%), 60 Hz (±1.2 Hz) and maximum total service current to the boiler per I&O manual Table 12.5.
Operating limits and other
ControlPureFire control with plain-English LCD displayLCD control board shows operational status in plain English (product page); control diagnostics use blocking/locking/warning code tables in I&O manual Section 10.
FuelNatural gas or LP gasNatural gas or propane with sulfur content below the limits in I&O manual Section 5; conversion-kit instructions are published on the product page.

Frequently asked questions

What are the PF-210's ratings?

42–210 MBH input, 195 MBH heating capacity and a 170 MBH net water rating at 95.1% AFUE per the ratings table.

Is the PF-210 ENERGY STAR certified?

Yes — the product page states the PureFire is ENERGY STAR certified, with one exception: the PF-300 model is not ENERGY STAR certified.

Why do the PF-300 and PF-399 print different efficiency figures?

Their rows print gross output and thermal efficiency (96.5% and 95.2%) instead of AFUE — the commercial rating convention used for the shared cut sheet's PF-300/PF-399/PFC-460 rows.

Questions about the Peerless PureFire PF-210?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate