Peerless Boilers · Error codes
Peerless PureFire A01 — Ignition Error
A01
IGNITION ERROR. Three consecutive unsuccessful ignition attempts (internal 1) - watch igniter through observation window; check spark electrode gap 3/16", spark presence, gas supply and pressures, flame signal log (Meas 1-4; Meas 4 below 1.7 uA will not stay running), flame sensor distance 1/8"-3/16" from burner, gas valve operation The table classifies it as locking.
If you smell gas
- Stop what you are doing. Do not use phones, switches, matches or anything that can spark inside.
- Go outside and leave the door open behind you.
- Call the FortisBC 24-hour emergency line at 1-800-663-9911 or dial 911.
Only after that, call ROMA about the boiler. Official guidance: FortisBC gas leaks and odour.
Applies to
This ignition fault code is displayed by the PureFire control on PureFire models (PF-50 through PF-399), as documented in PureFire PF-50–PF-399 Installation, Operating & Service Manual, IOM PF8248-R9 (PF8248-R9). Codes can differ between controller generations, so always check the manual that matches your unit.
- Peerless Boilers PureFire
- Peerless PureFire PF-50
- Peerless PureFire PF-80
- Peerless PureFire PF-110
- Peerless PureFire PF-140
- Peerless PureFire PF-200
- Peerless PureFire PF-210
- Peerless PureFire PF-300
- Peerless PureFire PF-399
Controller: PureFire control. Source manual: PF8248-R9 (2026-04).
Why a code is not a diagnosis
An ignition code says the burner did not prove a flame when it should have; it does not say why. Gas supply, ignition components, grounding, venting and the control module each need testing on site.
Safe things to observe
- If you smell gas, stop, go outside and call your gas utility's emergency line or 911 before anything else.
- Note the exact code and what the appliance was doing when it appeared.
- Check whether other gas appliances in the building are working.
Do not
- Do not keep resetting to force more ignition attempts.
- Do not open the gas valve, touch ignition components or bypass any safety device.
How professional service helps
- A licensed gas technician tests gas supply pressure and the shut-off state.
- The ignition probe, lead, gap and grounding are inspected against the manufacturer's specification.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Hot-surface igniter
A hot-surface igniter is a ceramic element that glows white-hot to light the burner in a gas boiler, and on many designs it doubles as the flame…
What a technician checks →Ignition electrode
The ignition electrode creates the spark that lights the burner in a gas boiler, and on many models it also senses the flame once it is burning.
What a technician checks →Flame sensor (flame rod)
The flame sensor is the small rod that proves a gas boiler's burner is actually lit before the control will keep the gas valve open.
What a technician checks →Gas valve
The gas valve is the boiler's controlled gateway for gas: it opens only when the control has proven safe conditions, meters the fuel to the burner,…
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
- Emergency Boiler Repair
Priority gas boiler repair for homes and buildings in Greater Vancouver with no heat, no hot water, a locked-out boiler or a leak.
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for Peerless Boilers PureFire.
Frequently asked questions
Does this code mean I have a gas leak?
Not by itself. If you smell gas, stop, leave the building and call your gas utility's emergency line or 911 from outside before anything else. Otherwise the code points to a fault a technician confirms on site.
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- PureFire PF-50–PF-399 Installation, Operating & Service Manual, IOM PF8248-R9 · PF8248-R9 · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.