Skip to content
Boilers.caby ROMA Heating & Cooling

Utica Boilers · Series

Utica Boilers MGB-K (MGB Series)

The MGB-K ('MGB Series') is Utica's current mid-efficiency cast-iron water boiler line: seven atmospheric chimney-vented sizes from 59 to 235 MBH at 84% AFUE, a dry-leg cast-iron heat exchanger, Hydrolevel control with built-in low water cut-off, and a 20-year non-prorated residential warranty. It is one of only two cast-iron Utica lines the official category page tags 'Available in Canada'.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
84% AFUE
Fuel
Natural gas or propane; the product page lists LP and natural-gas conversion kits and high-altitude orifice kits as options.
Venting
Atmospheric chimney vent — integral low-profile draft hood (draft diverter) with a motorized vent damper; 2021 DOE standard compliant.
Models documented
7

84% AFUE printed for every MGB-K size in the official brochure table (PN 240013193 Rev. 04/15/26).

About the MGB-K (MGB Series)

The MGB-K — titled 'MGB Series' on its product page — is Utica's current mid-efficiency cast-iron water boiler line. Checked on the official Gas Boilers category page on September 9, 2026, its card carries both the 'Current' and 'Available in Canada' tags. Utica describes seven models with inputs from 59 MBH to 235 MBH: a 2021 DOE standard-compliant design with electronic ignition and a motorized vent damper, an internal Hydrolevel operating control that adjusts water temperature to heating-system demand, and a built-in low water cut-off (LWCO). Water and gas piping can exit the left or right side of the boiler.

The official brochure table (PN 240013193 Rev. 04/15/26) prints the seven sizes: MGB-060K (59 MBH), MGB-095K (90.8), MGB-120K (120), MGB-150K (149), MGB-175K (175), MGB-205K (205) and MGB-235K (235), each at 84% AFUE with heating capacities of 50–197 MBH and net AHRI water ratings of 43–171 MBH, 1.9–4.6 gal of boiler water, 4"–7" flue connections and 2–8 burners. Cabinet widths run 13⅜" to 27½" on a shared 32⅛" height and 27¼"–27¾" depth, shipping 215–465 lb. Water return and supply are 1¼" NPT with ½" NPT gas — ¾" NPT on the MGB-205K/235K — and the line is wired 120 V AC 60 Hz at under 12 A.

The heat exchanger is cast iron with dry-leg end sections, and the boiler uses a pull-out burner drawer with a removable burner tube tray for service; safety devices include flame roll-out and blocked-vent shut-offs, and the integral low-profile draft diverter reduces installation height by up to 30 in compared with external draft hoods. Utica prints a 20-year non-prorated limited residential warranty plus 5-year parts, and the official footnote derates input 4% per 1,000 ft above 2,000 ft. The IOM prints indicator-light diagnostics rather than numeric fault codes; gas, venting and combustion work belongs with a licensed contractor.

Highlights

  • Current and 'Available in Canada' on Utica's Gas Boilers category page (checked 2026-09-09)
  • Seven sizes — MGB-060K through MGB-235K — with inputs from 59 to 235 MBH at 84% AFUE
  • Cast-iron heat exchanger with dry-leg end sections; pull-out burner drawer for service
  • Atmospheric chimney vent with integral low-profile draft hood and motorized vent damper
  • Hydrolevel control with built-in LWCO; left- or right-side water and gas piping
  • 1¼" NPT water return/supply; ½" NPT gas (¾" NPT on the 205K/235K); 20-year non-prorated residential warranty

20-year non-prorated limited residential warranty plus 5-year parts, as printed for the MGB-K line.

Models

MGB-K (MGB Series) models

One canonical page per model with input, output and efficiency kept separate.

Utica Boilers

Utica MGB-060K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-060K is a size in the current MGB-K cast-iron water line: 59 MBH fixed input, 50 MBH heating capacity, a 43 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 4" flue and 2 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-095K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-095K is a size in the current MGB-K cast-iron water line: 90.8 MBH fixed input, 76.3 MBH heating capacity, a 66 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 5" flue and 3 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-120K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-120K is a size in the current MGB-K cast-iron water line: 120 MBH fixed input, 101 MBH heating capacity, a 88 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 6" flue and 4 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-150K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-150K is a size in the current MGB-K cast-iron water line: 149 MBH fixed input, 125 MBH heating capacity, a 109 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 6" flue and 5 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-175K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-175K is a size in the current MGB-K cast-iron water line: 175 MBH fixed input, 147 MBH heating capacity, a 128 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 7" flue and 6 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-205K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-205K is a size in the current MGB-K cast-iron water line: 205 MBH fixed input, 172 MBH heating capacity, a 150 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 7" flue and 7 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-235K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-235K is a size in the current MGB-K cast-iron water line: 235 MBH fixed input, 197 MBH heating capacity, a 171 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 7" flue and 8 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Utica MGB-060K and Utica MGB-095K and Utica MGB-120K and Utica MGB-150K and Utica MGB-175K and Utica MGB-205K and Utica MGB-235K
SpecificationUtica MGB-060KUtica MGB-095KUtica MGB-120KUtica MGB-150KUtica MGB-175KUtica MGB-205KUtica MGB-235K
input-min———————
input-max———————
output-max———————
AFUE84 %84 %84 %84 %84 %84 %84 %
turndown———————
vent-max-3———————
vent-max-2———————
weight———————

Read the full comparison: Utica MGB-060K vs MGB-095K →

Read the full comparison: Utica MGB-095K vs MGB-120K →

Read the full comparison: Utica MGB-120K vs MGB-150K →

Read the full comparison: Utica MGB-150K vs MGB-175K →

Read the full comparison: Utica MGB-175K vs MGB-205K →

Error codes and alerts

MGB-K (MGB Series) alerts

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the Utica MGB-K cover?

Seven sizes as printed in the official brochure table: MGB-060K (59 MBH input), MGB-095K (90.8), MGB-120K (120), MGB-150K (149), MGB-175K (175), MGB-205K (205) and MGB-235K (235), all at 84% AFUE.

Is the MGB-K a condensing boiler?

No. The MGB-K is a non-condensing cast-iron boiler at 84% AFUE, vented atmospherically through a chimney with an integral draft hood and motorized vent damper — it is not a condensing design.

Is the MGB-K available in Canada?

Yes — the official Gas Boilers category card carries the 'Available in Canada' tag alongside 'Current' (checked 2026-09-09). Utica's French-Canadian distributor page names Morden National as the Canadian distributor contact.

What venting and connections does the MGB-K use?

Atmospheric chimney venting through an integral low-profile draft hood with a motorized vent damper; water return/supply is 1¼" NPT and gas is ½" NPT, stepping to ¾" NPT on the MGB-205K and MGB-235K.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate