Weil-McLain Evergreen EVG-399
The Evergreen EVG-399 tops the platform at 399 MBH input: the manual's 96.5% figure is combustion efficiency with gross output — not AFUE — so the CA page's "96.5% AFUE" claim misstates the rating of this 6.7-gallon, 260 lb boiler.
Key figures
- Max input
- 399 MBH
- Max CSA output
- 383 MBH
- AFUE
- —
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Weil-McLain Evergreen EVG-399 in practice
The EVG-399 is the largest Evergreen: 399 MBH CSA input, a 333 MBH net AHRI rating, and asterisked 383 MBH gross output with 96.5% combustion efficiency in the boiler manual's ratings table — figures the manual footnote and the US table state are gross output and combustion efficiency, not DOE AFUE. The CA residential page calls 96.5% "AFUE" on its spec block, which is the discrepancy behind Boilers.ca's separate efficiency note.
It runs on the 220-399 platform with 10:1 turndown, 4" venting only to 100 ft each side, 6.7 gallons of water content and a 260 lb shipping weight. Supply and return tappings are 1-1/2" NPT with 3/4" NPT gas, and like every Evergreen it is heating-only, designed to work with an indirect water heater for domestic hot water.
Best suited to
- Large residential plants and light-commercial loads above 300 MBH
- Cascaded Evergreen systems where the 399 anchors the high-load side
- Projects with a 4" vent route and gas supply sized for 399 MBH
Applicability and support
- Model number
- EVG-399
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 399 MBH | CSA input: 399,000 BTU/h. |
| Output | ||
| DOE heating capacity | 383 MBH | Asterisked gross output in the manual — not a DOE heating capacity figure. |
| Net AHRI water rating | 333 MBH | Net AHRI rating per the boiler manual ratings table. |
| Efficiency | ||
| Combustion efficiency | 96.5 % | 96.5% combustion efficiency with a 96.0% thermal efficiency per the boiler manual — this asterisked figure is NOT a DOE AFUE. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler; domestic hot water via an indirect tank or separate appliance | |
| Venting and air | ||
| Venting | 4" PVC, CPVC, polypropylene or AL29-4C stainless steel (Category IV); 4" pipe only on the 399 | Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit. |
| Max. equivalent vent/air length | 100 ft vent and 100 ft air | |
| Physical and connections | ||
| Weight | 260 lb | Approx. shipping weight per the brochure. |
| Gas connection | 3/4" NPT | |
| Heating water connections | 1-1/2" NPT | Supply and return tappings 1-1/2" on the 399; minimum recommended pipe 1-1/2". |
| Operating limits and other | ||
| Turndown | 10:1 | 10:1 turndown for the 220-399 sizes per the brochure and submittal. |
| Boiler water content | 6.7 gal | |
| Altitude rating | 2,000 ft | No modifications from sea level to 2,000 ft; auto-derate of about 4% per 1,000 ft above sea level. |
| Fuel | Natural gas or propane | Propane requires a conversion kit per the CA product page. |
Manuals
- Evergreen Boiler Manual — Sizes 220/299/300/399, 550-100-211/0122550-100-211/0122 · 2022-01
Alerts documented for this model
- Nothing shown on display screen and boiler will not respond to call for heat
- Nothing is shown in display screen and no other boiler components are operating
- Nothing is shown on display screen, but boiler is operating
- TEMP RISE TOO QUICKLY
- DISPLAY COMM Fault
- Hardware Fault
- LOW WTR CUTOFF OPEN
- SUPPLY 58° F > RETURN
- RETURN > SUPPLY
- SUPPLY WATER TEMPERATURE TOO HIGH
- TEMPERATURE SENSOR FAULT
- FLUE TEMP TOO HIGH
- LIMIT OPEN
- HIGH TEMP LIMIT
- FLAME FAULT
- GAS VALVE FAULT
- BLOWER FAULT
- IGNITION FAULT
- OUTDOOR SENSOR ERROR
- AIR PRESSURE Switch Open
- Closure Switch fault
Frequently asked questions
Is the EVG-399 really 96.5% AFUE?
No. The boiler manual asterisks the 399's 96.5% figure as combustion efficiency with 383 MBH gross output; DOE AFUE across the Evergreen line tops out at 95.1% on the 155.
What venting does the EVG-399 use?
4" pipe only — PVC, CPVC, polypropylene or AL29-4C stainless — to 100 feet each for vent and air.
What is the EVG-399's net rating?
333 MBH net AHRI water rating per the boiler manual ratings table.
Questions about the Weil-McLain Evergreen EVG-399?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Weil-McLain Canada — Evergreen · accessed September 7, 2026
- Evergreen Boiler Manual 550-100-211/0122 (220-399) · 550-100-211/0122 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.