HTP · Ultra (UFT & EFTU)

HTP EFTU-110WCN

The HTP EFTU-110WCN is the 110 MBH class wall-hung combi of the Elite Fire Tube Ultra line: 11.0 to 110 MBH input for central heating and the same range for domestic hot water, 95% DOE AFUE, 101 MBH DOE heating capacity and up to 2.6 GPM of DHW at a 77 °F rise.

CurrentCanadian status unknown

Key figures

Max input
110 MBH
Max CSA output
AFUE
95 %
Min input
11 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

HTP EFTU-110WCN in practice

The EFTU-110WCN is a wall-hung combination boiler of HTP's current Elite Fire Tube Ultra line — the code reads wall-hung (W), combi (C), natural gas (N), with propane conversion kits included. It fires 11.0 to 110.0 MBH for central heating and the same printed 11.0–110.0 MBH range for domestic hot water, at 95% DOE AFUE with 101 MBH DOE heating capacity and a 88 MBH net AHRI water rating. The official table prints DHW flows of 5.8 GPM at a 35 °F rise, 4.5 GPM at 45 °F and 2.6 GPM at 77 °F, with 1.5 gal of boiler water content and a 110 lb shipping weight.

It uses the SA-240-S43932 stainless steel vertical fire-tube heat exchanger (down-fired, ASME 'H') shared by the line, a 10:1 turndown, built-in ECM pump and the AristonThermo GALEVO2 control with LCD. The 85–150 sizes vent in 2" or 3" pipe — exhaust runs 6–150 ft in 3" (6–100 ft in 2" where allowed) and the intake 0–150 ft in 3" (0–100 ft in 2" where allowed), in PVC, CPVC, polypropylene or stainless steel, as a Category IV sealed-combustion direct-vent appliance. CH connections are 1-1/4" male NPT with 3/4" NPT gas; DHW inlet and outlet are 3/4" NPT on the combi models.

The combi models add the DHW setpoint range of 97–149 °F and produce domestic hot water directly, removing the separate tank. HTP backs the EFTU with a 15-year limited residential warranty when registered online. Boilers.ca records no official statement of Canadian sales, so canadianStatus stays 'unknown'; gas and combustion work belongs with a licensed contractor against LP-723 (Revision date 2.23.22).

Best suited to

  • Homes whose heat-loss calculation and hot-water draw fit a 110 MBH wall-hung combi
  • Projects replacing a tank plus boiler with one wall-hung appliance
  • Installations running 2" or 3" vent pipe in PVC, CPVC, polypropylene or stainless steel

Applicability and support

Model number
EFTU-110WCN
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by HTP. Units are shown with every value; notes flag conflicting sources or missing figures.

HTP EFTU-110WCN specifications
SpecificationValueNote
Input
Central-heating input, minimum (natural gas)11 MBH11,000 BTU/hr per the official model table.
Central-heating input, maximum (natural gas)110 MBH110,000 BTU/hr per the official model table.
Output
Heating capacity (DOE)101 MBHDOE heating capacity as printed in the official model table.
Net AHRI rating, water88 MBHNet AHRI water rating as printed in the official model table.
Efficiency
DOE AFUE95 %DOE AFUE as printed in the official model table (LP-740/LP-742).
Domestic hot water
DHW input, minimum11 MBH11,000 BTU/hr — the combi's DHW input range is printed equal to its CH range.
DHW input, maximum110 MBH110,000 BTU/hr — the combi's DHW input range is printed equal to its CH range.
DHW flow rate at 35 °F rise5.8 gpmDomestic hot water flow per the official combi table.
DHW flow rate at 45 °F rise4.5 gpmDomestic hot water flow per the official combi table.
DHW flow rate at 77 °F rise2.6 gpmDomestic hot water flow per the official combi table.
Venting and air
VentingExhaust 2" (6–100 ft) or 3" (6–150 ft); intake 2" (0–100 ft) or 3" (0–150 ft)Category IV, sealed-combustion direct vent / power vent. PVC, CPVC, polypropylene or stainless steel approved. Per LP-723, 199/199C models must be vented in 3" diameter pipe; all other models ship with 3" connections and may be reduced to 2".
Physical and connections
Shipping weight110 lbShipping weight as printed in the official model table.
Approximate full boiler weight107 lbApproximate full boiler weight as printed in the official model table.
Boiler water content1.5 galBoiler water content as printed in the official model table.
Dimensions (W x H x D)19.75" x 38.25" x 17"The 85–150 sizes share the 17" deep cabinet.
Gas supply pressureNatural gas 3.5"–10.5" w.c.; LP 8"–13" w.c.As printed in the LP-742 submittal technical table.
Water pressureHeat-exchanger MAWP 50 psi; pressure-relief valve 30 psiWater-pressure switch minimum 8 psi; freeze protection built in.
Heat exchangerSA-240-S43932 stainless steel vertical fire tube (ASME 'H'), down-firedChromium stainless steel vertical fire-tube design per LP-723 and the LP-742 submittal.
Electrical
Power supply120 V / 60 Hz, less than 12 A
Operating limits and other
FuelNatural gas or propaneAll models ship ready to operate on natural gas and come standard with liquid-propane conversion kits, per the product page.
Setpoint temperature rangesCH 68–122 °F low / 86–179 °F high; DHW 97–149 °FCombi model setpoint ranges as printed in the LP-742 submittal.
ControlAristonThermo LCD display / AristonThermo GALEVO2 controlBuilt-in ECM pump, 3-way valve and built-in bypass; DHW priority logic per LP-723.
Warranty15-year limited residential warranty when registered onlinePer the EFTU product page and the LP-707 warranty document.

Frequently asked questions

How much hot water does the EFTU-110WCN deliver?

The official table prints 5.8 GPM at a 35 °F rise, 4.5 GPM at 45 °F and 2.6 GPM at a 77 °F rise, with DHW input matching the central-heating range of 11.0 to 110 MBH.

Does the EFTU-110WCN need a separate hot-water tank?

No — the WCN models are combis: the boiler produces domestic hot water directly at the printed DHW setpoint range of 97–149 °F. The WBN boiler models need an indirect tank.

Can the EFTU-110WCN vent in 2" pipe?

Yes, on the non-199 sizes: exhaust 2" pipe runs 6–100 ft and intake 2" pipe 0–100 ft; 3" extends the runs to 150 ft.

Questions about the HTP EFTU-110WCN?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.