HTP EFTU-199WBN

The HTP EFTU-199WBN is the 199 MBH class wall-hung heating-only model of the Elite Fire Tube Ultra line: 19.9 to 199 MBH central-heating input at 95% DOE AFUE, 184 MBH DOE heating capacity and a 131 lb shipping weight.

CurrentCanadian status unknown

Key figures

Max input
199 MBH
Max CSA output
AFUE
95 %
Min input
19.9 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

HTP EFTU-199WBN in practice

The EFTU-199WBN is a wall-hung heating-only condensing boiler of HTP's current Elite Fire Tube Ultra line — the code reads wall-hung (W), boiler (B), natural gas (N), with propane conversion kits included. It fires 19.9 to 199.0 MBH for central heating at 95% DOE AFUE with 184 MBH DOE heating capacity and a 160 MBH net AHRI water rating, weighing 131 lb shipping (139.5 lb full) with 2.8 gal of boiler water content.

It uses the SA-240-S43932 stainless steel vertical fire-tube heat exchanger (down-fired, ASME 'H') shared by the line, a 10:1 turndown, built-in ECM pump and the AristonThermo GALEVO2 control with LCD. The 199 model must be vented in 3" diameter pipe — exhaust runs 6–150 ft in 3" (6–100 ft in 2" where allowed) and the intake 0–150 ft in 3" (0–100 ft in 2" where allowed), in PVC, CPVC, polypropylene or stainless steel, as a Category IV sealed-combustion direct-vent appliance. CH supply/return are 1-1/4" male NPT, the indirect return 3/4" male NPT and the gas inlet 3/4" male NPT, so an indirect water heater connects to the boiler's own return port.

These are heating-only boiler models — domestic hot water comes from an indirect tank on the system, with the printed DHW indirect setpoint range of 97–149 °F. HTP backs the EFTU with a 15-year limited residential warranty when registered online. Boilers.ca records no official statement of Canadian sales, so canadianStatus stays 'unknown'; gas and combustion work belongs with a licensed contractor against LP-723 (Revision date 2.23.22).

Best suited to

  • Homes whose heat-loss calculation fits inside 199 MBH of heating input
  • Wall-hung boiler replacements with a separate indirect hot-water tank
  • Installations that can vent in 3" pipe (mandatory on the 199)

Applicability and support

Model number
EFTU-199WBN
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by HTP. Units are shown with every value; notes flag conflicting sources or missing figures.

HTP EFTU-199WBN specifications
SpecificationValueNote
Input
Central-heating input, minimum (natural gas)19.9 MBH19,900 BTU/hr per the official model table.
Central-heating input, maximum (natural gas)199 MBH199,000 BTU/hr per the official model table.
Output
Heating capacity (DOE)184 MBHDOE heating capacity as printed in the official model table.
Net AHRI rating, water160 MBHNet AHRI water rating as printed in the official model table.
Efficiency
DOE AFUE95 %DOE AFUE as printed in the official model table (LP-740/LP-742).
Venting and air
VentingExhaust and intake 3" only — exhaust 6–150 ft, intake 0–150 ftCategory IV, sealed-combustion direct vent / power vent. PVC, CPVC, polypropylene or stainless steel approved. Per LP-723, 199/199C models must be vented in 3" diameter pipe; all other models ship with 3" connections and may be reduced to 2".
Physical and connections
Shipping weight131 lbShipping weight as printed in the official model table.
Approximate full boiler weight139.5 lbApproximate full boiler weight as printed in the official model table.
Boiler water content2.8 galBoiler water content as printed in the official model table.
Dimensions (W x H x D)19.75" x 38.25" x 18.5"The 199 sizes use the deeper cabinet.
Gas supply pressureNatural gas 3.5"–10.5" w.c.; LP 8"–13" w.c.As printed in the LP-740/LP-742 submittal technical tables.
Water pressureHeat-exchanger MAWP 50 psi; pressure-relief valve 30 psiWater-pressure switch minimum 8 psi; freeze protection built in.
Heat exchangerSA-240-S43932 stainless steel vertical fire tube (ASME 'H'), down-firedChromium stainless steel vertical fire-tube design per LP-723 and the LP-740 submittal.
Electrical
Power supply120 V / 60 Hz, less than 12 A
Operating limits and other
FuelNatural gas or propaneAll models ship ready to operate on natural gas and come standard with liquid-propane conversion kits, per the product page.
Boiler setpoint temperature range68–122 °F low temperature / 86–179 °F high temperatureDHW indirect setpoint range 97–149 °F as printed for the boiler models.
ControlAristonThermo LCD display / AristonThermo GALEVO2 controlBuilt-in ECM pump, 3-way valve and bypass for indirect / primary-secondary elimination on the boiler models.
Warranty15-year limited residential warranty when registered onlinePer the EFTU product page and the LP-707 warranty document.

Frequently asked questions

Is the EFTU-199WBN a combi boiler?

No — the WBN models are heating-only boilers. Domestic hot water is produced by an indirect tank connected to the boiler's 3/4" indirect return; HTP's combi models carry WCN codes.

What does the EFTU-199WBN weigh?

The official table prints a 131 lb shipping weight and a 139.5 lb approximate full boiler weight, with 2.8 gal of boiler water content.

Can the EFTU-199WBN vent in 2" pipe?

No. LP-723 states 199/199C models must be vented in 3" diameter pipe (exhaust 6–150 ft, intake 0–150 ft).

Questions about the HTP EFTU-199WBN?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.