IBC SL G3 “Low RPM / air flow” alert
Error – Low RPM / Air Flow
The manual lists this alert when the combustion fan is below 1,150 RPM at the end of fan pre-purge, or below 100 RPM during heating. The control needs a verified fan speed before it can safely manage combustion air.
If a carbon-monoxide alarm sounds
- Leave the building immediately and get fresh air.
- Call 911. Do not go back inside until emergency services say it is safe.
- Have every fuel-burning appliance inspected before use.
Only after that, call ROMA about the boiler. Official guidance: Health Canada on carbon monoxide.
Applies to
This alert is shown by the V-10 touchscreen controller on SL Series G3 residential boilers (SL 10-85 G3, SL 14-115 G3, SL 20-160 G3 and SL 30-199 G3), as documented in IBC Installation & Operating Manual — SL 10-85 G3 / SL 14-115 G3 / SL 20-160 G3 / SL 30-199 G3, doc 120-276E13, sections 9.2–9.4.
Controller: V-10 touchscreen controller. Source manual: 120-276E13 (2026-08-11).
Why a code is not a diagnosis
Low fan speed can come from a blocked vent or combustion-air intake, a failing fan or fan bearing, a loose or damaged wiring connection, or a control fault. The alert does not identify which; the vent path and the fan circuit are checked separately.
Safe things to observe
- Note the alert and whether the fan sounds noisy, rattles or does not spin at all.
- From a safe distance, check the vent terminal and combustion-air inlet for visible blockage.
- If a CO alarm sounds, leave the building and call 911 from outside.
Do not
- Do not poke anything into the fan or vent openings.
- Do not keep resetting the boiler while the fan or vent fault is unresolved.
How professional service helps
- A technician inspects the complete vent and combustion-air path, including terminations and any screens.
- The fan wiring, harness and control output are tested, and the fan is replaced if faulty.
- Air-flow and fan-speed readings are verified through a full firing cycle.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Combustion fan (blower)
The combustion fan is the sealed boiler's lungs: it draws in combustion air, keeps the burner's gas-air mixture correct, and pushes flue gases out…
What a technician checks →Boiler venting (flue and air intake)
A condensing boiler vents cool, wet flue gases through dedicated plastic pipe that must meet ULC S636 in Canada and the boiler manufacturer's own…
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for IBC Technologies SL Series G3.
Frequently asked questions
Can a blocked vent cause this alert?
Yes. The manual lists blocked venting as a primary check for low fan speed or air-flow alerts. A boiler must never be run with a suspected blocked vent because combustion depends on the fan moving the right volume of air.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- IBC Installation & Operating Manual — SL 10-85 G3 / SL 14-115 G3 / SL 20-160 G3 / SL 30-199 G3, doc 120-276E13, sections 9.2–9.4 · 120-276E13 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.