IBC DC 33-160

The IBC DC 33-160 is the largest DC combi: 33–160 MBH input, 30.4–140 MBH output at 94% AFUE, a 4.0 USgpm maximum DHW flow and a 164 W full-fire draw. IBC's DC page prints its DHW input as 33–124 MBH.

DiscontinuedHistorically in Canada

Key figures

Max input
160 MBH
Max CSA output
140 MBH
AFUE
94 %
Min input
33 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

IBC DC 33-160 in practice

The DC 33-160 was the top size of IBC's discontinued DC combi line, covering 33–160 MBH CSA input (9.7–46.9 kW) for 30.4–140 MBH output (8.9–41.0 kW) at 94% AFUE. It uses the line's 43.5 psig space-heating coil and 150 psig DHW coil and draws 164 W at full fire with the internal pump — the highest in the range.

Its domestic-hot-water row needs a caveat: the DC specification table prints the DHW input as 33–124 MBH even though the model's heating input is 33–160 MBH and the DHW kW cell prints 9.7–36.3 kW, so the MBH cell appears to carry over the DC 33-124 figure. Boilers.ca records the page as printed and flags the discrepancy.

The 33-160 weighs 105 lb (48 kg), holds 0.5 USG (1.9 L) and allows a 4.0 USgpm maximum DHW flow with activation at 0.5 USgpm. It is covered by DC I&O manual 120-183-A-R11. IBC's November 2019 service notice also applies: it covers a heat-exchanger gasket upgrade for DC 33-160 units built July 2014–November 2016, so owners should check the serial range with a licensed contractor.

Best suited to

  • Owners of a DC 33-160 checking the gasket service notice and serial range
  • Larger homes where the 140 MBH output matches the original combi load
  • Technicians documenting the printed DHW-input discrepancy in the DC table

Applicability and support

Model number
DC 33-160
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.

IBC DC 33-160 specifications
SpecificationValueNote
Input
Input, minimum33 MBH9.7 kW
Input, maximum160 MBH46.9 kW
Output
CSA output, minimum30.4 MBH8.9 kW
CSA output, maximum140 MBH41.0 kW
Efficiency
Efficiency (AFUE)94 %Per the DC specification table.
Domestic hot water
DHW input33 – 124 MBH33–124 MBH as printed on the DC specification table; the model's heating input is 33–160 MBH and the DHW kW cell prints 9.7–36.3 kW.
Max. DHW flow rate4 USgpm
Flow to activate DHW0.5 USgpm
Domestic hot waterIntegrated DHW coil in a combination boiler
Venting and air
Max. equivalent vent length, 3"120 ftEach side.
Max. equivalent vent length, 2"35 ftEach side.
Physical and connections
Weight (empty)105 lb48 kg
Pressure vessel water content0.5 USG / 1.9 L
Electrical
Power use at full fire (internal pump)164 W120 V / 60 Hz.
Operating limits and other
Maximum boiler flow rate11 USgpm
Minimum boiler flow rate3 USgpm
FuelNatural gas or propaneThe DC/HC specification table notes conversion kits must be ordered separately.
Gas supply pressure5 – 14 in. w.c.
Ambient temperature32 – 122 °F0 – 50°C.
Space-heating water temperature50 – 194 °F10 – 90°C.
Domestic hot water temperature104 – 149 °F40 – 65°C.
Max. operating pressure, space-heating coil43.5 psigDHW coil rated 150 psig; the unit ships with a 30 psig pressure relief valve.
Altitude rating12,000 ft

Frequently asked questions

Is there a service notice for the DC 33-160?

Yes. IBC's November 2019 notice covers a heat-exchanger gasket upgrade for HC 33-160 and DC 33-160 units built July 2014–November 2016. Owners should check the serial range with a licensed contractor.

Why does the DC 33-160 DHW input show 33–124 MBH?

That is what the DC specification table prints; the model's heating input is 33–160 MBH and the DHW kW cell reads 9.7–36.3 kW, so the MBH cell appears to be a carry-over from the DC 33-124 column. Boilers.ca records it as printed.

How much hot water does the DC 33-160 make?

A maximum DHW flow of 4.0 USgpm, with activation at 0.5 USgpm and DHW temperatures of 104–149°F.

Questions about the IBC DC 33-160?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate