Skip to content
Boilers.caby ROMA Heating & Cooling

Laars Heating Systems · FT Series Wall

Laars FTHW140

The Laars FTHW140 is the mid-size FT Series Wall heating-only boiler: a wall-hung condensing unit rated 140,000 BTU/h on the manual cover, natural gas from the factory with propane field-convertible, on the NGTB-900CP control.

CurrentSold in Canada

Key figures

Max input
140 MBH
Max CSA output
—
AFUE
—
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Laars FTHW140 in practice

The FTHW140 sits between the 100 and 199 MBH heating-only steps of the FT wall line — the manual (Document 1483C) prints it at 140,000 BTU/h. It is a wall-hung condensing boiler on the NGTB-900CP control, documented with natural gas as the factory configuration and propane field-convertible.

Diagnostics follow the two-digit FT code family in Section 6.1, with each code typed as a Soft Lock or Hard Lock; the FTHW140 is heating-only, so there is no integrated domestic hot water production and no DHW component codes of its own beyond the shared table entries.

Best suited to

  • Homes whose heat-loss calculation lands between the 100 and 199 MBH steps
  • Heating-only systems where 140 MBH of ceiling covers the design-day load
  • Projects wanting the FTHW heat-only layout without stepping up to the 199

Applicability and support

Model number
FTHW140
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Laars Heating Systems. Units are shown with every value; notes flag conflicting sources or missing figures.

Laars FTHW140 specifications
SpecificationValueNote
Input
Maximum input (as printed)140 MBHPrinted on the installation manual cover as the FTHW 140,000 BTU/h model (Document 1483C).
Domestic hot water
Domestic hot waterNone built in — heating-only model; hot water comes from a separate tank or water heater
Operating limits and other
FuelNatural gas or propaneNatural gas is the factory configuration; propane is field-convertible per the manual cover.
Error reportingTwo-digit numeric codes with Soft Lock and Hard Lock classes per Section 6.1 of the installation manual

Frequently asked questions

How does the FTHW140 differ from the FTHW100?

Only the rating step differs within the same heating-only wall design: the FTHW140 is printed at 140,000 BTU/h against the FTHW100's 100,000 BTU/h. Both share the FT wall manual, code family and fuel configuration.

Is the FTHW140 a combi boiler?

No. It is the heating-only FTHW variant; the combi versions of the wall series are the FTCW140 and FTCW199 models documented in their own manual (Document 1487C).

Can the FTHW140 be converted to propane?

The manual cover states propane is field-convertible, meaning the boiler ships in the natural-gas factory configuration and conversion is a licensed gas-fitting task done with Laars' published procedure and parts.

Questions about the Laars FTHW140?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate