Laars Heating Systems FT Series Wall

The FT Series Wall is Laars' wall-hung condensing line for Canada: the FTHW heating-only boiler in 100, 140 and 199 MBH and the FTCW combination boiler in 140 and 199 MBH, rated 95% AFUE, running on the NGTB-900CP control and reporting two-digit numeric error codes.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas is the factory configuration on the models covered by the researched manuals; propane is field-convertible.
Venting
2" or 3" PVC, CPVC or approved polypropylene venting, up to 50 equivalent ft in 2" and 100 in 3" per the FT Series Wall installation documentation. In Canada, plastic venting must be a ULC S636-certified system where required.
Models documented
5
Warranty
Not verified

95% AFUE published for the FT Series Wall line.

About the FT Series Wall

Laars' FT Series Wall covers both sides of the residential market in one condensing platform: the FTHW heating-only models are printed on the manual cover as 100,000, 140,000 and 199,000 BTU/h, and the FTCW combination models as 140,000 and 199,000 BTU/h with domestic hot water produced by the combi itself. The series is rated 95% AFUE and runs on the NGTB-900CP control; the installation manuals (Document 1483C for the heating-only FTHW and Document 1487C for the FTCW combi) name natural gas as the factory configuration with propane field-convertible.

The FT wall control shows two-digit numeric error codes — from code 10 for repeated flame extinction through codes for the condensate trap, sensors, fan, gas-leak detection, low-water cut-off and anti-freeze protection up to code 94 for exhaust-gas temperature. Each code is classified in the manual's Section 6.1 tables as a Soft Lock, which clears on its own when the condition is corrected, or a Hard Lock that needs an action such as turning power off and on or replacing a part.

Because the heating-only and combi manuals are separate documents (1483C and 1487C), their code tables are not identical: the combi tables add DHW and mixing-valve entries such as codes 66 and 68 for the mixing valve, while the heating-only table carries entries like code 29 for a loose connection on the PCB. Owners should read a code from the manual for the unit's own model and document number.

Highlights

  • Wall-hung condensing series: FTHW heating-only 100/140/199 plus FTCW combi 140/199
  • 95% AFUE across the line
  • NGTB-900CP control with two-digit numeric codes, Soft Lock and Hard Lock classes
  • Natural gas factory configuration; propane field-convertible per the manuals
  • Separate I&O documents per variant: 1483C (heating-only) and 1487C (combi)
  • 2" venting to 50 equivalent ft or 3" to 100 equivalent ft

Models

FT Series Wall models

One canonical page per model with input, output and efficiency kept separate.

Laars Heating Systems

Laars FTHW100

CurrentSold in Canada
Input
Output (max)
AFUE

The Laars FTHW100 is the smallest FT Series Wall heating-only boiler: a wall-hung condensing unit rated 100,000 BTU/h on the manual cover, natural gas from the factory with propane field-convertible, on the NGTB-900CP control.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars FTHW140

CurrentSold in Canada
Input
Output (max)
AFUE

The Laars FTHW140 is the mid-size FT Series Wall heating-only boiler: a wall-hung condensing unit rated 140,000 BTU/h on the manual cover, natural gas from the factory with propane field-convertible, on the NGTB-900CP control.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars FTHW199

CurrentSold in Canada
Input
Output (max)
AFUE

The Laars FTHW199 is the top heating-only size of the FT Series Wall: a wall-hung condensing boiler rated 199,000 BTU/h on the manual cover, natural gas from the factory with propane field-convertible, on the NGTB-900CP control.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars FTCW140

CurrentSold in Canada
Input
Output (max)
AFUE

The Laars FTCW140 is the smaller FT Series Wall combination boiler: a wall-hung condensing combi rated 140,000 BTU/h on its manual cover (Document 1487C) with integrated domestic hot water and the FTCW combi code table.

Natural gasPropaneCombi

Laars Heating Systems

Laars FTCW199

CurrentSold in Canada
Input
Output (max)
AFUE

The Laars FTCW199 is the largest FT Series Wall combination boiler: a wall-hung condensing combi rated 199,000 BTU/h on its manual cover (Document 1487C) with integrated domestic hot water, on the NGTB-900CP control.

Natural gasPropaneCombi

Compare models in this series

Comparison of Laars FTHW100 and Laars FTHW140 and Laars FTHW199 and Laars FTCW140 and Laars FTCW199
SpecificationLaars FTHW100Laars FTHW140Laars FTHW199Laars FTCW140Laars FTCW199
input-min
Maximum input (as printed)100 MBH140 MBH199 MBH140 MBH199 MBH
output-max
afue
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Laars FTHW100 vs FTHW140

Read the full comparison: Laars FTHW140 vs FTHW199

Read the full comparison: Laars FTCW140 vs FTCW199

Read the full comparison: Laars FTCW140 vs FTHW140

Read the full comparison: Laars FTCW199 vs FTHW199

Error codes and alerts

FT Series Wall alerts

  • 10Laars FT wall control (NGTB-900CP)
  • 11Laars FT wall control (NGTB-900CP)
  • 16Laars FT wall control (NGTB-900CP)
  • 20Laars FT wall control (NGTB-900CP)
  • 28Laars FT wall control (NGTB-900CP)
  • 29Laars FT wall control (NGTB-900CP)
  • 32Laars FT wall control (NGTB-900CP)
  • 33Laars FT wall control (NGTB-900CP)
  • 35Laars FT wall control (NGTB-900CP)
  • 36Laars FT wall control (NGTB-900CP)
  • 37Laars FT wall control (NGTB-900CP)
  • 38Laars FT wall control (NGTB-900CP)
  • 40Laars FT wall control (NGTB-900CP)
  • 41Laars FT wall control (NGTB-900CP)
  • 42Laars FT wall control (NGTB-900CP)
  • 43Laars FT wall control (NGTB-900CP)
  • 44Laars FT wall control (NGTB-900CP)
  • 45Laars FT wall control (NGTB-900CP)
  • 61Laars FT wall control (NGTB-900CP)
  • 66Laars FT wall control (NGTB-900CP)
  • 68Laars FT wall control (NGTB-900CP)
  • 70Laars FT wall control (NGTB-900CP)
  • 72Laars FT wall control (NGTB-900CP)
  • 76Laars FT wall control (NGTB-900CP)
  • 77Laars FT wall control (NGTB-900CP)
  • 78Laars FT wall control (NGTB-900CP)
  • 80Laars FT wall control (NGTB-900CP)
  • 81Laars FT wall control (NGTB-900CP)
  • 85Laars FT wall control (NGTB-900CP)
  • 94Laars FT wall control (NGTB-900CP)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Services for Laars Heating Systems boilers

Frequently asked questions

What is the difference between FTHW and FTCW wall models?

The FTHW models are heating-only boilers (100, 140 and 199 MBH) while the FTCW models are combination boilers (140 and 199 MBH) that also produce domestic hot water. Both are wall-hung condensing units on the FT wall platform.

Do FT wall error codes clear themselves?

Some do. The manuals classify each two-digit code as a Soft Lock, which clears when the condition is remedied, or a Hard Lock, which needs an action such as cycling power or replacing a sensor or switch. Follow the code's own procedure in Section 6.1 of the manual.

Are the heating-only and combi FT wall error tables the same?

Not exactly. The combi manual (Document 1487C) adds DHW and mixing-valve codes such as 66 and 68, while the heating-only manual (Document 1483C) carries entries such as code 29 for a PCB connection fault. Read codes from the manual for the unit's own variant.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate