Laars FTHW199 in practice

The FTHW199 tops the heating-only range of the FT wall line at 199,000 BTU/h as printed on the cover of Document 1483C. It is the same wall-hung condensing platform as the FTHW100 and FTHW140, running the NGTB-900CP control with natural gas as the factory configuration and propane field-convertible.

Its Section 6.1 table covers the full two-digit FT code family — from repeated flame-extinguishment (10) and ignition-failure (11) codes through low-water cut-off (80, 81), anti-freeze (85) and exhaust-gas temperature (94) codes — with Soft Lock and Hard Lock recovery typed per code. As the largest heating-only wall model it is the size a heat-loss calculation reaches only when the load genuinely approaches 199 MBH.

Best suited to

  • Larger homes whose heat-loss calculation approaches the 199 MBH ceiling
  • Heating-only plants wanting the maximum FT wall input without the combi's DHW plumbing
  • Systems feeding radiators or in-floor loops through a separate hot-water appliance

Applicability and support

Model number
FTHW199
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Laars Heating Systems. Units are shown with every value; notes flag conflicting sources or missing figures.

Laars FTHW199 specifications
SpecificationValueNote
Input
Maximum input (as printed)199 MBHPrinted on the installation manual cover as the FTHW 199,000 BTU/h model (Document 1483C).
Domestic hot water
Domestic hot waterNone built in — heating-only model; hot water comes from a separate tank or water heater
Operating limits and other
FuelNatural gas or propaneNatural gas is the factory configuration; propane is field-convertible per the manual cover.
Error reportingTwo-digit numeric codes with Soft Lock and Hard Lock classes per Section 6.1 of the installation manual

Frequently asked questions

When is the FTHW199 the right size?

When a room-by-room heat-loss calculation (plus any recovery load) genuinely needs more than the 140 MBH step on a design day. Extra input without a matching load does not improve comfort or efficiency.

Does the FTHW199 have any DHW codes?

As a heating-only model it produces no domestic hot water. The FT wall heating-only manual still carries shared entries such as the DHW-outlet sensor code where the code tables overlap the combi platform, which is why codes should be read against the FTHW manual, Document 1483C.

What venting does the FT wall series use?

The FT wall installation documentation allows 2" or 3" PVC, CPVC or approved polypropylene venting, up to 50 equivalent ft in 2" and 100 in 3". In Canada, plastic venting must be a ULC S636-certified system where required.

Questions about the Laars FTHW199?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate