Lochinvar Noble LWCO — Low Water Cutoff is not Making
LWCO
Low water cutoff is not making. The low water cutoff (LWCO) is not making, so check boiler pump operation on a call for heat, closed valves or obstructions in the boiler piping, system water level and purging, the jumper across terminals 11 and 12, and fuse F3, and replace the LWCO if needed. The table classifies it as Lockout (manual reset).
Applies to
This low-water or pressure protection code is displayed by the SMART CONTROL on Noble fire-tube models (NKB080–199 boilers, NKC110–199 and NCF110–199 combis), as documented in Noble Installation & Service Manual, doc 100275091 Rev AN — fault tables (100275091 Rev AN). Codes can differ between controller generations, so always check the manual that matches your unit.
- Lochinvar Noble Fire Tube (NKB/NKC/NCF)
- Lochinvar Noble NKB080
- Lochinvar Noble NKB110
- Lochinvar Noble NKB150
- Lochinvar Noble NKB199
- Lochinvar Noble NKC110
- Lochinvar Noble NKC150
- Lochinvar Noble NKC199
- Lochinvar Noble NCF110
- Lochinvar Noble NCF150
- Lochinvar Noble NCF199
Controller: SMART CONTROL. Source manual: 100275091 Rev AN.
Why a code is not a diagnosis
A water-pressure or low-water code can mean a genuine leak or empty system, a failed expansion tank, a faulty fill valve, or a sensor problem. The appliance does not distinguish these.
Safe things to observe
- Read the pressure gauge and compare it with the normal cold-system pressure your installer set.
- Look for drips or wet spots near the appliance, pipes and the relief-valve discharge.
Do not
- Do not keep re-pressurizing a system that keeps losing water.
- Do not cap a relief-valve discharge pipe.
How professional service helps
- A technician finds and repairs the leak, checks the expansion tank and fill assembly, and verifies the sensor circuit.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Low-water cutoff
A low-water cutoff is the safety device that stops a boiler from firing when there is not enough water inside it.
What a technician checks →Circulator pump
The circulator is the pump that moves heated water from a boiler out to the radiators, baseboards or in-floor loops and back again.
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
- Emergency Boiler Repair
Priority gas boiler repair for homes and buildings in Greater Vancouver with no heat, no hot water, a locked-out boiler or a leak.
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for Lochinvar Noble Fire Tube (NKB/NKC/NCF).
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Noble Installation & Service Manual, doc 100275091 Rev AN — fault tables · 100275091 Rev AN · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.