The Noble is Lochinvar's compact fire-tube series in three mountings — NKB heating boilers (80-199), NKC wall-hung combis (110-199) and NCF floor combis (110-199) — all rated 95.0% AFUE, sold under the Epic name in Canada and run by the SMART CONTROL with text-name faults.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
95% AFUE
Fuel
Natural gas or propane; the ratings tables name natural gas with "N" and propane with "L" (Knight and Noble) or with an N-to-L change (Noble NKB).
Venting
Category IV sealed combustion; PVC, CPVC, polypropylene or stainless steel per the I&O manual — 2" venting is allowed to 100 equivalent ft on the 80-110 sizes, 60 ft on the 150 and 50 ft on the 199, with 3" venting to 100 ft on every size. For Canada, plastic venting must be ULC S636 certified; stainless steel systems must be listed to ULC S636 in Canada.
Models documented
10

95.0% AFUE across the Noble series per the I&O ratings table.

About the Noble Fire Tube (NKB/NKC/NCF)

The Noble fire-tube line splits by job: the NKB80-199 models are wall-hung heating-only boilers with 1" sweat water connections and no domestic hot water, while the NKC110-199 wall-hung combis and NCF110-199 floor-standing combis add on-demand DHW through 3/4" DHW connections. Every model in the I&O ratings table is 95.0% AFUE, and the combi product pages describe the SMART CONTROL's diverter arrangement as eliminating the cold-water "sandwich" between DHW draws.

Lochinvar's residential boilers page marks the Noble wall-mount boiler, combi wall mount and combi floor mount as "Sold as Epic® in Canada," while the manuals and product pages themselves use the Noble name. The SMART CONTROL reports faults as text-name messages on the boiler interface — such as Flame Fail Ign, Air Pressure Switch or Combi Sensor Fault — rather than numeric codes, and Boilers.ca documents each against the Noble I&O manual's troubleshooting chart. Product pages print a 10-year heat exchanger and 5-year parts warranty, and the 110 combi pages quote DHW of up to 2.6 GPM at a 77°F rise.

Highlights

  • Fire-tube series in three forms: NKB boiler, NKC wall combi, NCF floor combi
  • 95.0% AFUE across the line per the I&O ratings table
  • Sold as "Epic" in Canada on Lochinvar's residential boilers page
  • SMART CONTROL displays text-name faults, not numeric codes
  • 2" venting option to 100/60/50 equivalent ft by size; 3" to 100 ft on all sizes
  • 10-yr heat exchanger and 5-yr parts warranty printed on the product pages

Lochinvar's product pages print a 10-year heat exchanger warranty and a 5-year parts warranty for the Noble boiler and combi.

Models

Noble Fire Tube (NKB/NKC/NCF) models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
8.3–80 MBH
Output (max)
AFUE
95 %

The Noble NKB080 is the smallest Noble heating boiler: 8.3 to 80 MBH input at 95.0% AFUE with a 1.2-gallon water content, 1" sweat connections and 2" or 3" venting to 100 feet.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The Noble NKB110 is the 110 MBH Noble heating boiler: 11 to 110 MBH input at 95.0% AFUE with 102 MBH DOE capacity, sharing the Noble ratings table with the NKC110 and NCF110 combis.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The Noble NKB150 is the 150 MBH Noble heating boiler: 15 to 150 MBH input at 95.0% AFUE with 139 MBH DOE capacity, 1" sweat connections and 2" venting to 60 equivalent feet.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The Noble NKB199 tops the Noble boiler line at 19.9 to 199 MBH input and 185 MBH DOE capacity, 95.0% AFUE, with 2" venting limited to 50 equivalent feet.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The Noble NKC110 is the entry Noble wall-hung combi: 11 to 110 MBH input at 95.0% AFUE, rated for DHW of up to 2.6 GPM at a 77°F rise, with 3/4" DHW connections.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The Noble NKC150 is the 150 MBH Noble wall-hung combi: 15 to 150 MBH space-heating input at 95.0% AFUE with 139 MBH DOE capacity and a 2-gallon water content.

Natural gasPropaneCombi
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The Noble NKC199 is the top Noble wall-hung combi: 19.9 to 199 MBH space-heating input at 95.0% AFUE with 185 MBH DOE capacity, DHW on demand through 3/4" connections.

Natural gasPropaneCombi
CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The Noble NCF110 is the entry Noble floor-standing combi: 11 to 110 MBH input at 95.0% AFUE, rated for DHW of up to 2.6 GPM at a 77°F rise, on a 290 lb floor cabinet.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The Noble NCF150 is the 150 MBH floor-standing Noble combi: 15 to 150 MBH input at 95.0% AFUE with 139 MBH DOE capacity and on-demand DHW through 3/4" connections.

Natural gasPropaneCombi
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The Noble NCF199 is the largest Noble floor combi: 19.9 to 199 MBH input at 95.0% AFUE with 185 MBH DOE capacity, on-demand DHW and 2" venting to 50 equivalent feet.

Natural gasPropaneCombi

Compare models in this series

Comparison of Lochinvar Noble NKB080 and Lochinvar Noble NKB110 and Lochinvar Noble NKB150 and Lochinvar Noble NKB199 and Lochinvar Noble NKC110 and Lochinvar Noble NKC150 and Lochinvar Noble NKC199 and Lochinvar Noble NCF110 and Lochinvar Noble NCF150 and Lochinvar Noble NCF199
SpecificationLochinvar Noble NKB080Lochinvar Noble NKB110Lochinvar Noble NKB150Lochinvar Noble NKB199Lochinvar Noble NKC110Lochinvar Noble NKC150Lochinvar Noble NKC199Lochinvar Noble NCF110Lochinvar Noble NCF150Lochinvar Noble NCF199
Heating input, minimum8.3 MBH11 MBH15 MBH19.9 MBH11 MBH15 MBH19.9 MBH11 MBH15 MBH19.9 MBH
Heating input, maximum80 MBH110 MBH150 MBH199 MBH110 MBH150 MBH199 MBH110 MBH150 MBH199 MBH
output-max
Efficiency (AFUE)95 %95 %95 %95 %95 %95 %95 %95 %95 %95 %
turndown
Max. equivalent vent/air length, 3"100 ft100 ft100 ft100 ft100 ft100 ft100 ft100 ft100 ft100 ft
Max. equivalent vent/air length, 2"100 ft100 ft60 ft50 ft100 ft60 ft50 ft100 ft60 ft50 ft
Shipping weight123 lb153 lb290 lb

Read the full comparison: Lochinvar Noble NKB080 vs NKB110

Read the full comparison: Lochinvar Noble NKB110 vs NKB150

Read the full comparison: Lochinvar Noble NKB150 vs NKB199

Read the full comparison: Lochinvar Noble NKC110 vs NKC150

Read the full comparison: Lochinvar Noble NKC150 vs NKC199

Read the full comparison: Lochinvar Noble NCF110 vs NCF150

Read the full comparison: Lochinvar Noble NCF150 vs NCF199

Read the full comparison: IBC SFC 199-1 Superflow vs Lochinvar Noble NKC199

Error codes and alerts

Noble Fire Tube (NKB/NKC/NCF) alerts

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Which Noble model should I choose: NKB, NKC or NCF?

The NKB (80-199 MBH) is a wall-hung heating-only boiler for systems with an indirect tank. The NKC and NCF are combis that produce domestic hot water on demand — the NKC hangs on a wall and the NCF stands on the floor — and both span 110-199 MBH.

Why is the Noble sometimes called Epic?

Lochinvar's residential boilers page labels each Noble entry "Sold as Epic® in Canada." The product pages and the Noble installation manual use the Noble name, and Lochinvar's Canada English pages are identical to its United States pages.

How much hot water does a Noble combi deliver?

The NKC110 and NCF110 product pages quote DHW of up to 2.6 GPM at a 77°F temperature rise, and Lochinvar's combi marketing copy describes DHW of up to 4.8 GPM. Actual delivery depends on input, incoming water temperature and the draw pattern.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate