Lochinvar · Noble Fire Tube (NKB/NKC/NCF)
Lochinvar Noble NKB199
The Noble NKB199 tops the Noble boiler line at 19.9 to 199 MBH input and 185 MBH DOE capacity, 95.0% AFUE, with 2" venting limited to 50 equivalent feet.
Key figures
- Max input
- 199 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 19.9 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Lochinvar Noble NKB199 in practice
The NKB199 is the largest Noble heating boiler: 19.9 to 199 MBH of input with 185 MBH of DOE heating capacity and a 161 MBH AHRI net rating at 95.0% AFUE. Its 2.7-gallon water content is the highest in the NKB range, and its territory is large homes and small multi-suite buildings whose heat-loss calculation approaches 200 MBH.
It keeps the 1" sweat water connections of the NKB line (combi models use NPT) with a 1/2" gas connection. The 2" venting option tightens to 50 equivalent feet at the 199 size while 3" remains at 100, so longer routes run in 3". Heating-only, it is driven with an indirect tank through the SMART CONTROL, and Lochinvar sells it in Canada under the Epic name per its residential page.
Best suited to
- Large homes and small multi-suite buildings with loads near 199 MBH
- High-recovery indirect-tank systems in a compact wall-hung boiler
- Owners wanting the largest Noble boiler without combi plumbing
Applicability and support
- Model number
- NKB199L
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 19.9 MBH | Per the I&O ratings table. |
| Heating input, maximum | 199 MBH | Per the I&O ratings table. |
| Output | ||
| DOE heating capacity | 185 MBH | DOE heating capacity per the I&O ratings table. |
| AHRI net water rating | 161 MBH | Net AHRI rating based on a piping and pickup allowance of 1.15. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the I&O ratings table. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler | The NKB is heating-only; Lochinvar's residential page pairs the Noble wall-mount boiler with the Squire indirect water heater. |
| Venting and air | ||
| Venting | Category IV sealed combustion; PVC, CPVC, polypropylene or stainless steel | In Canada, plastic venting must be a ULC S636-certified system. |
| Max. equivalent vent/air length, 2" | 50 ft | Table 3D (air intake/vent piping sizes), I&O manual. |
| Max. equivalent vent/air length, 3" | 100 ft | Table 3D (air intake/vent piping sizes), I&O manual. |
| Physical and connections | ||
| Water content | 2.7 gal | Per the I&O ratings table. |
| Space-heating water connections | 1" (sweat) | Noble ratings: NPT connections are used on combi units, sweat connections on the boiler. |
| Gas connection | 1/2" | Per the I&O ratings table. |
Manuals
Alerts documented for this model
- Memory Error
- Fan Speed
- LWCO
- Flame Sequence
- Outlet ARHL
- Air Pressure Switch
- AUX Limit Fault
- Flame Fail: Running
- Flame Fail: Ignition
- Flue Temp Limit
- Flue Temp High
- Outlet MRHL
- Outlet Temp High
- Outlet Temp DIFF
- Flue Sensor Fault
- Outlet Sensor Fault
- Inlet Sensor Fault
- Set Point Met
- Anti-Cycling
- Delta T High
- Low Voltage
- No Flue Temp Change
- Combi Sensor Fault (Combi Only)
- Lockout Inlet Sensor Fault
- Outdoor Sensor Missing
- No Hot Water at Faucets (Combi Only)
- DHW Water is not Hot Enough (Combi Only)
- Combi Boiler is Running but Does Not Supply Heated Water to Space Heating System (Combi Only)
- Space Heating System Heat Emitters Get Hot During a DHW Draw and the Combi Boiler does not Provide Hot Enough Domestic Hot Water (Combi Only)
- Lockout! Water Press Switch
Frequently asked questions
What are the NKB199's ratings?
19.9 to 199 MBH of input, 185 MBH DOE heating capacity and a 161 MBH AHRI net rating at 95.0% AFUE, per the Noble I&O ratings table.
Can the NKB199 use 2" venting?
Yes, but only to 50 equivalent feet at the 199 size; 3" venting reaches 100 equivalent feet, per Table 3A of the I&O manual.
Questions about the Lochinvar Noble NKB199?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Lochinvar Noble NKB150 vs NKB199Comparison
- Lochinvar Noble NKB080Same series
- Lochinvar Noble NKB110Same series
- Lochinvar Noble NKB150Same series
- Lochinvar Noble NKC110Same series
- Lochinvar Noble NKC150Same series
- Lochinvar Noble NKC199Same series
- Lochinvar Noble NCF110Same series
- Lochinvar Noble NCF150Same series
- Lochinvar Noble NCF199Same series
- Noble Fire Tube (NKB/NKC/NCF) series hub
- Buying guide