The NTI Trinity Lx150 is the entry size of the Lx fire-tube line: 25 to 150 MBH input on natural gas (145 MBH maximum on LP) at 93.5% AFUE, in a 100 lb floor-standing unit that can also use the wall-hung kits NTI includes for the Lx200–400.

CurrentSold in Canada

Key figures

Max input
150 MBH
Max CSA output
AFUE
93.5 %
Min input
25 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI Trinity Lx150 in practice

The Lx150 is the smallest Trinity Lx and the residential-friendly end of NTI's fire-tube range, firing 25 to 150 MBH on natural gas with the LP maximum capped at 145 MBH. NTI rates it 93.5% AFUE on the product page, it weighs 100 lb, and its 3" venting runs to 105 ft on natural gas but only 50 ft on LP.

For a larger BC home or small commercial space whose heat-loss calculation sits above the residential wall-hung class, the Lx150 is the lightest entry into the Lx line. The trade-offs to plan around are its floor-standing footprint (or wall-hung kit, which NTI includes for the Lx200–400 range) and the shorter LP vent run, which matters for propane-heated buildings.

Best suited to

  • Larger homes and light-commercial spaces with loads above 150 MBH-class wall boilers
  • Projects wanting the easy-to-clean Lx fire-tube heat exchanger at the smallest size
  • NG installations able to run 3" venting up to 105 ft per side

Applicability and support

Model number
Lx150
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI Trinity Lx150 specifications
SpecificationValueNote
Input
Input, minimum25 MBHPer the NTI product page.
Input, maximum150 MBHNatural gas. The LP maximum is 145 MBH per the NTI product page.
Efficiency
Efficiency (AFUE)93.5 %Per the NTI product page.
Domestic hot water
Domestic hot waterHeating-only; pair with an indirect tank or separate water heater
Venting and air
Max. equivalent vent length105 ft (NG), 50 ft (LP)3" pipe per side; maximum equivalent run per the NTI product page.
Physical and connections
Weight100 lbPer the NTI product page.
Water connections1" NPT femalePer the NTI product page.
Gas connection1/2" NPT femalePer the NTI product page.
Operating limits and other
FuelNatural gas or propaneNTI publishes LP conversion instructions for this series.

Manuals

Alerts documented for this model

Services

Frequently asked questions

Can the Lx150 run on propane?

Yes, but NTI caps the LP input at 145 MBH (against 150 MBH on natural gas) and limits the 3" LP vent run to 50 ft instead of 105 ft.

Is the Lx150 wall-hung?

It is a floor-standing boiler. NTI's page introduction says sizes up to 399 MBH can also be mounted wall-hung, and the features list says the wall-hung kit is included for the Lx200–400.

What is the Lx150's efficiency?

93.5% AFUE per the NTI product page, the same figure NTI publishes for the Lx200.

Questions about the NTI Trinity Lx150?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate