Rinnai IP175S

The Rinnai IP175S is the 175k heating-only I-Series+ solo on the large chassis, marketed on rinnai.ca as available since September 2024 and documented on Boilers.ca from the EN I&O manual (doc 800000216) at 112.4 lb. It is named in Health Canada recall RA-77507.

CurrentSold in Canada

Key figures

Max input
175 MBH
Max CSA output
—
AFUE
96 %
Min input
15 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Rinnai IP175S in practice

The IP175S brings the I-Series+ solo line onto the large chassis at 175,000 BTU/h of central-heating input; rinnai.ca's product page carries "AVAILABLE Sept 2024" launch copy. The product page and the English I&O manual (doc 800000216) agree on a 112.4 lb weight, and the unit is heating-only with hot water via an indirect tank.

This model is named in Health Canada recall RA-77507 (updated 2025-06-05): IP175S units sold between September 2024 and February 2025 with serial numbers beginning in S may have a boiler door that fails to seal, a carbon-monoxide hazard, with a free repair through Rinnai America at 800-621-9419.

Best suited to

  • Heating-only loads near 175 MBH of input served through an indirect tank
  • Owners who prefer the solo line's heating-only simplicity at large capacity
  • Large-chassis wall-hung installs (19.45 x 15.48 in) where an IP150S is undersized

Applicability and support

Model number
IP175S
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Rinnai. Units are shown with every value; notes flag conflicting sources or missing figures.

Rinnai IP175S specifications
SpecificationValueNote
Input
Heating input, minimum15 MBH15,000 BTU/h minimum input per the EN I&O manual spec table.
Heating input, maximum175 MBHCentral-heating maximum input per the EN I&O manual spec table (doc 800000216); the product page headline reads '175k BTU Solo Heat'.
Efficiency
Efficiency (AFUE)96 %Up to 96% AFUE per Rinnai Canada marketing copy and the Canadian brochure; no per-model AFUE figure is printed in the I&O manual spec tables.
Domestic hot water
Domestic hot waterHeating-only boiler; domestic hot water via an indirect tankNo DHW connections on the solo (spec Table 3); indirect-tank setting range 120°F-150°F (50°C-65°C) per spec Table 2.
Venting and air
Venting2" nominal PVC/polypropylene or 3" x 5" concentricVent connection per the I&O manual; direct-vent (concentric or twin-pipe) and room-air options are covered in the manual's venting section.
Max. equivalent vent length, 2"75 ftTwin-pipe 2" maximum equivalent length per the 175k+ solo I&O manual (Table 20).
Max. equivalent vent length, 3"160 ftTwin-pipe 3" maximum equivalent length per the 175k+ solo I&O manual (Table 20).
Physical and connections
Weight112.4 lb112.4 lb (50.9 kg) per the product page; the EN I&O manual spec table prints 112.4 lb (51 kg) — the two sources agree.
Water content (CH)2.4 galCentral-heating water content per spec Table 2.
Gas connection3/4" NPTPer spec Table 3.
Heating water connections1" NPTCH supply and return per spec Table 3.
Width19.45 in (494 mm)Per the I&O manual dimension figure and the product page.
Depth15.48 in (393.3 mm)Per the I&O manual dimension figure and the product page.
Operating limits and other
FuelNatural gas or propaneGas supply pressure per spec Table 2: NG 3.5-10.5 in. W.C. (0.87-2.61 kPa); propane 8.0-13.5 in. W.C. (1.99-3.36 kPa).
CH water pressure13 – 45 psiCH pressure per the EN I&O manual spec table for 175k+ solos: minimum 13 PSI, maximum 55 PSI (379 kPa); recommended 17-26 PSI; 30 PSI relief valve included.

Frequently asked questions

Does the IP175S make domestic hot water?

No. The IP175S is a heating-only solo: spec Table 3 lists only gas, CH supply and CH return connections with no DHW, so hot water comes from an indirect tank the boiler controls.

Is the IP175S recalled in Canada?

Yes — Health Canada recall RA-77507 covers the IP175S, IP199S, IP175199C and IP199199C sold between September 2024 and February 2025 with serial numbers beginning in S. Follow the Health Canada alert for the free repair process.

How big is the IP175S?

It uses the large I-Series+ chassis: 19.45 in wide and 15.48 in deep, with a body height of 34.88 in per the manual (the product page lists 45.3 in), and weighs 112.4 lb per both sources.

Questions about the Rinnai IP175S?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification