Skip to content
Boilers.caby ROMA Heating & Cooling

Rinnai · i-Series+ Solo

Rinnai IP150S

The Rinnai IP150S is the largest fully documented I-Series+ solo: a heating-only condensing boiler firing 15 to 150 MBH of input at 64.8 lb per the manual, controlling an indirect tank for domestic hot water.

CurrentSold in Canada

Key figures

Max input
150 MBH
Max CSA output
AFUE
96 %
Min input
15 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Rinnai IP150S in practice

The IP150S tops the documented solo range at 150,000 BTU/h of central-heating input while keeping the small-chassis format: 18.5 x 11.5 in, 0.88 gal of CH water and a 10.9 sq ft heat exchanger. The I&O manual prints its weight at 64.8 lb (29.4 kg); the product page's 62.6 lb is documented as a discrepancy with the manual figure used here.

Heating-only, the IP150S has no DHW connections: hot water comes from an indirect tank the boiler manages, with tank recovery priority as the documented default and a parameter to permit simultaneous CH and tank operation. Venting runs to 75 equivalent feet in 2" or 160 in 3" twin pipe.

Beyond this model the solo line continues with the IP175S and IP199S, which remain draft records here pending review of their raster-only English I&O manuals. Efficiency shown is the family marketing claim of up to 96% AFUE.

Best suited to

  • The largest heating loads that still fit the small 18.5 x 11.5 in chassis
  • Indirect-tank systems needing up to 150 MBH of recovery input
  • Owners sizing a solo rather than a combi where a tank is preferred

Applicability and support

Model number
IP150S
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Rinnai. Units are shown with every value; notes flag conflicting sources or missing figures.

Rinnai IP150S specifications
SpecificationValueNote
Input
Heating input, minimum15 MBHSpace-heating input; 15,000 BTU/h minimum input per spec Table 2.
Heating input, maximum150 MBHSpace-heating (CH) maximum input per spec Table 2.
Efficiency
Efficiency (AFUE)96 %Up to 96% AFUE per Rinnai Canada marketing copy and the Canadian brochure; no per-model AFUE figure is printed in the I&O manual spec tables.
Domestic hot water
Domestic hot waterHeating-only boiler; domestic hot water via an indirect tankNo DHW connections on the solo (spec Table 3); indirect-tank setting range 120°F-150°F (50°C-65°C) per spec Table 2.
Venting and air
Venting2" nominal PVC/polypropylene or 3" x 5" concentricVent connection per the I&O manual; direct-vent (concentric or twin-pipe) and room-air options are covered in the manual's venting section.
Max. equivalent vent length, 2"75 ftTwin-pipe 2" PVC / 2" PP maximum equivalent length per the solo I&O manual (Table 20).
Max. equivalent vent length, 3"160 ftTwin-pipe 3" PVC / 3" PP maximum equivalent length per the solo I&O manual (Table 20).
Physical and connections
Weight64.8 lb64.8 lb (29.4 kg) per the I&O manual spec Table 2; the product page lists 62.6 lb (28.3 kg) — a page/manual discrepancy; the manual figure is used here.
Water content (CH)0.88 galCentral-heating water content per spec Table 2.
Gas connection3/4" NPTPer spec Table 3.
Heating water connections1" NPTCH supply and return per spec Table 3.
Width18.5 in (470 mm)Per the I&O manual dimension figure and the product page.
Depth11.5 in (291 mm)Per the I&O manual dimension figure; the product page lists 292.1 mm.
Operating limits and other
FuelNatural gas or propaneGas supply pressure per spec Table 2: NG 3.5-10.5 in. W.C. (0.87-2.61 kPa); propane 8.0-13.5 in. W.C. (1.99-3.36 kPa).
CH water pressure13 – 45 psiMinimum 13 PSI (90 kPa), maximum 45 PSI (310 kPa); recommended 17-26 PSI; 30 PSI pressure relief valve included with the system (spec Table 2).

Frequently asked questions

What is the IP150S's weight per the manual?

64.8 lb (29.4 kg) per the solo I&O manual spec table. The product page prints 62.6 lb, a documented discrepancy — the manual figure is used on Boilers.ca.

Can the IP150S heat a home and a tank at the same time?

Yes, with the documented parameter setting: the solo manual defaults to indirect-tank recovery priority, and setting parameter 33 to "b" permits simultaneous central heating and tank recovery.

Which models come above the IP150S?

The IP175S (175 MBH) and IP199S (199 MBH). Both are draft records on Boilers.ca pending review of their raster-only I&O manuals, and both are named in Health Canada recall RA-77507.

Questions about the Rinnai IP150S?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate