Skip to content
Boilers.caby ROMA Heating & Cooling

Rinnai · i-Series+ Solo

Rinnai IP090S

The Rinnai IP090S is the mid-size I-Series+ solo: a heating-only condensing boiler firing 15 to 90 MBH of input at the same 62.6 lb and small-chassis footprint as the IP060S, with hot water via an indirect tank.

CurrentSold in Canada

Key figures

Max input
90 MBH
Max CSA output
AFUE
96 %
Min input
15 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Rinnai IP090S in practice

The IP090S shares the entry chassis with the IP060S — 62.6 lb, 0.75 gal of CH water, 18.5 x 11.5 in — but fires higher: 15,000 to 90,000 BTU/h of central-heating input. As a heating-only solo it has no DHW connections, and the I&O manual documents indirect-tank control with recovery priority by default.

Solo venting is uniform across the ≤150k line per the manual: 75 equivalent feet in 2" twin pipe or 160 in 3". Supply connections are 3/4" NPT gas and 1" NPT heating.

The family efficiency claim is up to 96% AFUE (marketing copy); the manual prints no per-model AFUE figure. The control reports plain numeric codes (no E prefix), with solo-only rows for indirect-tank codes in the solo manual.

Best suited to

  • Homes with an indirect tank whose heat loss fits under 90 MBH
  • A step up in heating reach without a chassis or weight change
  • Mechanical rooms where the light 62.6 lb wall mount matters

Applicability and support

Model number
IP090S
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Rinnai. Units are shown with every value; notes flag conflicting sources or missing figures.

Rinnai IP090S specifications
SpecificationValueNote
Input
Heating input, minimum15 MBHSpace-heating input; 15,000 BTU/h minimum input per spec Table 2.
Heating input, maximum90 MBHSpace-heating (CH) maximum input per spec Table 2.
Efficiency
Efficiency (AFUE)96 %Up to 96% AFUE per Rinnai Canada marketing copy and the Canadian brochure; no per-model AFUE figure is printed in the I&O manual spec tables.
Domestic hot water
Domestic hot waterHeating-only boiler; domestic hot water via an indirect tankNo DHW connections on the solo (spec Table 3); indirect-tank setting range 120°F-150°F (50°C-65°C) per spec Table 2.
Venting and air
Venting2" nominal PVC/polypropylene or 3" x 5" concentricVent connection per the I&O manual; direct-vent (concentric or twin-pipe) and room-air options are covered in the manual's venting section.
Max. equivalent vent length, 2"75 ftTwin-pipe 2" PVC / 2" PP maximum equivalent length per the solo I&O manual (Table 20).
Max. equivalent vent length, 3"160 ftTwin-pipe 3" PVC / 3" PP maximum equivalent length per the solo I&O manual (Table 20).
Physical and connections
Weight62.6 lb62.6 lb (28.4 kg) per the I&O manual spec Table 2; the product page lists 62.6 lb (28.3 kg).
Water content (CH)0.75 galCentral-heating water content per spec Table 2.
Gas connection3/4" NPTPer spec Table 3.
Heating water connections1" NPTCH supply and return per spec Table 3.
Width18.5 in (470 mm)Per the I&O manual dimension figure and the product page.
Depth11.5 in (291 mm)Per the I&O manual dimension figure; the product page lists 292.1 mm.
Operating limits and other
FuelNatural gas or propaneGas supply pressure per spec Table 2: NG 3.5-10.5 in. W.C. (0.87-2.61 kPa); propane 8.0-13.5 in. W.C. (1.99-3.36 kPa).
CH water pressure13 – 45 psiMinimum 13 PSI (90 kPa), maximum 45 PSI (310 kPa); recommended 17-26 PSI; 30 PSI pressure relief valve included with the system (spec Table 2).

Frequently asked questions

How does the IP090S differ from the IP060S?

Only in heating reach: 90,000 BTU/h maximum input against 60,000 BTU/h. Both weigh 62.6 lb, share the small chassis and have identical venting and connections.

Is the IP090S a combi boiler?

No. The S suffix marks the heating-only solo line: no domestic hot water is produced inside the unit, so an indirect tank or another appliance supplies DHW.

What error codes does a solo show that a combi does not?

Solo-only rows in the manual include 371 (indirect thermistor) and 831 (indirect tank temperature); combi-only rows such as 021, 651 and 661 do not apply to the solo.

Questions about the Rinnai IP090S?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate