Rinnai IP199S

The Rinnai IP199S is the top heating-only I-Series+ solo at 199 MBH of central-heating input on the large chassis, documented on Boilers.ca from the EN I&O manual (doc 800000216) at 112.4 lb. It is named in Health Canada recall RA-77507.

CurrentSold in Canada

Key figures

Max input
199 MBH
Max CSA output
AFUE
96 %
Min input
15 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Rinnai IP199S in practice

The IP199S is the largest I-Series+ solo, firing to 199,000 BTU/h of central-heating input for the line's maximum heating-only reach. It shares the large chassis (19.45 x 15.48 in) and 112.4 lb weight with the IP175S per both the product page and the English I&O manual, and like every solo it carries no DHW connections — hot water comes from an indirect tank.

This model is named in Health Canada recall RA-77507 (updated 2025-06-05): IP199S units sold between September 2024 and February 2025 with serial numbers beginning in S may have a boiler door that fails to seal, a carbon-monoxide hazard, with a free repair through Rinnai America at 800-621-9419.

Best suited to

  • The maximum heating-only reach of the I-Series+ solo line: 199 MBH of input
  • Large homes whose heat-loss calculation approaches 199 MBH, with DHW via an indirect tank
  • Owners wanting the solo 15.6 sq ft heat exchanger at the top of the line

Applicability and support

Model number
IP199S
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Rinnai. Units are shown with every value; notes flag conflicting sources or missing figures.

Rinnai IP199S specifications
SpecificationValueNote
Input
Heating input, minimum15 MBH15,000 BTU/h minimum input per the EN I&O manual spec table.
Heating input, maximum199 MBHCentral-heating maximum input per the EN I&O manual spec table (doc 800000216); the product page headline reads '199k BTU Solo Heat'.
Efficiency
Efficiency (AFUE)96 %Up to 96% AFUE per Rinnai Canada marketing copy and the Canadian brochure; no per-model AFUE figure is printed in the I&O manual spec tables.
Domestic hot water
Domestic hot waterHeating-only boiler; domestic hot water via an indirect tankNo DHW connections on the solo (spec Table 3); indirect-tank setting range 120°F-150°F (50°C-65°C) per spec Table 2.
Venting and air
Venting2" nominal PVC/polypropylene or 3" x 5" concentricVent connection per the I&O manual; direct-vent (concentric or twin-pipe) and room-air options are covered in the manual's venting section.
Max. equivalent vent length, 2"75 ftTwin-pipe 2" maximum equivalent length per the 175k+ solo I&O manual (Table 20).
Max. equivalent vent length, 3"160 ftTwin-pipe 3" maximum equivalent length per the 175k+ solo I&O manual (Table 20).
Physical and connections
Weight112.4 lb112.4 lb (50.9 kg) per the product page; the EN I&O manual spec table prints 112.4 lb (51 kg) — the two sources agree.
Water content (CH)2.4 galCentral-heating water content per spec Table 2.
Gas connection3/4" NPTPer spec Table 3.
Heating water connections1" NPTCH supply and return per spec Table 3.
Width19.45 in (494 mm)Per the I&O manual dimension figure and the product page.
Depth15.48 in (393.3 mm)Per the I&O manual dimension figure and the product page.
Operating limits and other
FuelNatural gas or propaneGas supply pressure per spec Table 2: NG 3.5-10.5 in. W.C. (0.87-2.61 kPa); propane 8.0-13.5 in. W.C. (1.99-3.36 kPa).
CH water pressure13 – 45 psiCH pressure per the EN I&O manual spec table for 175k+ solos: minimum 13 PSI, maximum 55 PSI (379 kPa); recommended 17-26 PSI; 30 PSI relief valve included.

Frequently asked questions

What heat exchanger does the IP199S use?

The 15.6 sq ft heat exchanger per the 175k+ solo I&O manual (doc 800000216) spec table — the same unit as the IP175S — with 2.4 gal of CH water content.

Is the IP199S recalled in Canada?

Yes — Health Canada recall RA-77507 covers the IP199S, IP175S, IP175199C and IP199199C sold between September 2024 and February 2025 with serial numbers beginning in S. Follow the Health Canada alert for the free repair process.

What is the difference between the IP199S and the IP175S?

Only the firing range: the IP199S reaches 199,000 BTU/h of CH input and the IP175S 175,000 BTU/h. Both use the large chassis and the same 112.4 lb weight per the manual.

Questions about the Rinnai IP199S?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.