Skip to content
Boilers.caby ROMA Heating & Cooling

Rinnai · i-Series+ Solo

Rinnai IP060S

The Rinnai IP060S is the smallest I-Series+ solo: a heating-only condensing boiler firing 15 to 60 MBH of input with no built-in hot-water production, documented from the solo I&O manual 800000191(02) at 62.6 lb.

CurrentSold in Canada

Key figures

Max input
60 MBH
Max CSA output
AFUE
96 %
Min input
15 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Rinnai IP060S in practice

The IP060S is the entry heating-only model of the I-Series+ solo line: a wall-hung condensing boiler that fires 15,000 to 60,000 BTU/h for central heating and makes no domestic hot water itself. Hot water comes from an indirect tank the boiler controls — the manual's default is indirect-tank recovery priority, with parameter 33 able to permit simultaneous tank and CH operation.

At 62.6 lb (28.4 kg) it is the lightest Rinnai boiler documented on Boilers.ca, holding 0.75 gal of CH water in the small 18.5 x 11.5 in chassis. Supply connections are 3/4" NPT gas and 1" NPT heating with no DHW connections at all, and venting is 2" twin pipe to 75 equivalent feet or 3" to 160.

The solo's control shows fault codes without an E prefix, with solo-only rows such as 371 (indirect thermistor) and 831 (indirect tank temperature) in its manual's tables. Efficiency shown is the family marketing claim of up to 96% AFUE; the manual spec table prints no per-model figure.

Best suited to

  • Homes that already use or prefer an indirect tank for domestic hot water
  • Low-heat-loss buildings whose calculation fits under 60 MBH of input
  • Owners who want heating-only simplicity without combi DHW components

Applicability and support

Model number
IP060S
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Rinnai. Units are shown with every value; notes flag conflicting sources or missing figures.

Rinnai IP060S specifications
SpecificationValueNote
Input
Heating input, minimum15 MBHSpace-heating input; 15,000 BTU/h minimum input per spec Table 2.
Heating input, maximum60 MBHSpace-heating (CH) maximum input per spec Table 2.
Efficiency
Efficiency (AFUE)96 %Up to 96% AFUE per Rinnai Canada marketing copy and the Canadian brochure; no per-model AFUE figure is printed in the I&O manual spec tables.
Domestic hot water
Domestic hot waterHeating-only boiler; domestic hot water via an indirect tankNo DHW connections on the solo (spec Table 3); indirect-tank setting range 120°F-150°F (50°C-65°C) per spec Table 2.
Venting and air
Venting2" nominal PVC/polypropylene or 3" x 5" concentricVent connection per the I&O manual; direct-vent (concentric or twin-pipe) and room-air options are covered in the manual's venting section.
Max. equivalent vent length, 2"75 ftTwin-pipe 2" PVC / 2" PP maximum equivalent length per the solo I&O manual (Table 20).
Max. equivalent vent length, 3"160 ftTwin-pipe 3" PVC / 3" PP maximum equivalent length per the solo I&O manual (Table 20).
Physical and connections
Weight62.6 lb62.6 lb (28.4 kg) per the I&O manual spec Table 2; the product page lists 62.6 lb (28.3 kg).
Water content (CH)0.75 galCentral-heating water content per spec Table 2.
Gas connection3/4" NPTPer spec Table 3.
Heating water connections1" NPTCH supply and return per spec Table 3.
Width18.5 in (470 mm)Per the I&O manual dimension figure and the product page.
Depth11.5 in (291 mm)Per the I&O manual dimension figure; the product page lists 292.1 mm.
Operating limits and other
FuelNatural gas or propaneGas supply pressure per spec Table 2: NG 3.5-10.5 in. W.C. (0.87-2.61 kPa); propane 8.0-13.5 in. W.C. (1.99-3.36 kPa).
CH water pressure13 – 45 psiMinimum 13 PSI (90 kPa), maximum 45 PSI (310 kPa); recommended 17-26 PSI; 30 PSI pressure relief valve included with the system (spec Table 2).

Frequently asked questions

Does the IP060S make domestic hot water?

No. As a heating-only "solo" it has no DHW connections; domestic hot water is produced by an indirect tank controlled by the boiler.

How is the indirect tank controlled?

Per the solo I&O manual, the boiler defaults to indirect-tank recovery priority; parameter 33 set to "b" permits simultaneous central heating and tank recovery, and parameter 29 selects thermostat or thermistor tank control.

What are the IP060S venting limits?

75 equivalent feet in 2" twin-pipe PVC/polypropylene or 160 in 3", per the solo I&O manual (Table 20).

Questions about the Rinnai IP060S?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.