Viessmann · Vitocrossal 200 (CI2)
Viessmann Vitocrossal 200 CI2-2000
The Vitocrossal 200 CI2-2000 tops the CI2 line at 2000 MBH: 100 to 2000 MBH rated input (29.3 to 586 kW) at 96.5% combustion efficiency, weighing 1969 lb (893 kg) with 99 USG of boiler water content.
Key figures
- Max input
- 2,000 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- 100 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Viessmann Vitocrossal 200 CI2-2000 in practice
The CI2-2000 is the largest of the six Vitocrossal 200 CI2 models and the size behind the page's capacity story: maximum rated input of 2,000,000 BTU (586 kW) on natural gas or liquid propane, from a 100,000 BTU (29.3 kW) minimum fire.
At 1969 lb (893 kg) it is the heaviest unit in the series, with 99 USG of boiler water content per the technical data manual — the row the page's 'highest water volume in class (99 USG)' headline matches. It carries an 8-inch flue collar (the largest in the line), runs two burner control units on the Viessmann One Base platform, and prints the series' lowest combustion-efficiency figure at 96.5%.
All series features apply: Inox-Crossal stainless steel heat exchanger, MatriX cylinder burner with Lambda PrO₂ combustion trim, turndown up to 30:1, no primary boiler pump required and altitude operation to 10,000 ft without derate. Service coverage is the CI2 service instructions (doc 6175 797 - 23, 04/2026).
Best suited to
- The largest single-boiler loads on the CI2 range — up to 2000 MBH of input
- Commercial plants wanting maximum per-boiler capacity in side-by-side cascades
- High-water-volume systems matching the page's 99 USG headline figure
Applicability and support
- Model number
- CI2-2000
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Rated input, minimum (natural gas/LPG) | 100 MBH | 100,000 BTU (29.3 kW), per the product page |
| Rated input, maximum (natural gas/LPG) | 2,000 MBH | 2,000,000 BTU (586 kW), per the product page |
| Efficiency | ||
| Combustion efficiency | 96.5 % | Per-size combustion efficiency as printed on the product page and technical data manual. |
| Physical and connections | ||
| Weight | 1,969 lb | 893 kg |
| Operating limits and other | ||
| Boiler water content | 99 USG | Per the technical data manual (doc 5472 803 - 13). |
Manuals
Alerts documented for this model
- F.7
- F.8
- F.13
- F.14
- F.29
- F.30
- F.49
- F.50
- F.57
- F.58
- F.59
- F.62
- F.63
- F.64
- F.65
- F.67
- F.69
- F.71
- F.72
- F.74
- F.77
- F.87
- F.89
- F.91
- F.92
- F.94
- F.99
- F.100
- F.104
- F.142
- F.160
- F.180
- F.182
- F.183
- F.184
- F.185
- F.299
- F.342
- F.343
- F.344
- F.347
- F.348
- F.353
- F.354
- F.364
- F.365
- F.369
- F.370
- F.371
- F.378
- F.379
- F.380
- F.381
- F.382
- F.383
- F.416
- F.425
- F.430
- F.446
- F.453
- F.454
- F.457
- F.473
- F.517
- F.519
- F.520
- F.527
- F.528
- F.541
- F.542
- F.543
- F.544
- F.545
- F.546
- F.547
- F.548
- F.549
- F.574
- F.575
- F.576
- F.577
- F.578
- F.579
- F.580
- F.581
- F.582
- F.583
- F.584
- F.585
- F.623
- F.624
- F.625
- F.626
- F.627
- F.628
- F.629
- F.630
- F.688
- F.691
- F.692
- F.694
- F.762
- F.764
- F.765
- F.875
- F.882
- F.883
- F.884
- F.885
- F.886
- F.887
- F.888
- F.889
- F.890
- F.891
- F.892
- F.893
- F.894
- F.895
- F.896
- F.897
- F.920
- F.921
- F.922
- F.971
- F.982
- F.986
- F.1001
- F.1002
- F.1004
- F.1061
- F.1062
Frequently asked questions
What is the firing range of the CI2-2000?
From a 100,000 BTU (29.3 kW) minimum input up to 2,000,000 BTU (586 kW) maximum, per the product page's NG/LPG rated-input row — the top of the CI2 single-boiler range.
How efficient is the CI2-2000?
Its per-size spec row prints 96.5% combustion efficiency, the lowest figure in the CI2 series (which starts at 97% on the CI2-399/500).
How big is the CI2-2000?
It weighs 1969 lb (893 kg) per the product page, holds 99 USG of water per the technical data manual and uses an 8-inch flue collar — the largest collar printed in the series.
Questions about the Viessmann Vitocrossal 200 CI2-2000?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Viessmann Vitocrossal 200 CI2-1500 vs CI2-2000Comparison
- Viessmann Vitocrossal 200 CI2-399Same series
- Viessmann Vitocrossal 200 CI2-500Same series
- Viessmann Vitocrossal 200 CI2-750Same series
- Viessmann Vitocrossal 200 CI2-1000Same series
- Viessmann Vitocrossal 200 CI2-1500Same series
- Vitocrossal 200 (CI2) series hub
- Buying guide
Sources and verification
- Viessmann Canada — Vitocrossal 200 CI2 product page · accessed September 9, 2026
- Service Instructions — Vitocrossal 200 CI2 series, doc 6175 797 - 23 · 6175 797 - 23 · accessed September 9, 2026
- Technical Data Manual — Vitocrossal 200 CI2, doc 5472 803 - 13 · 5472 803 - 13 · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.