Viessmann Vitocrossal 200 F.87 — Burner in a Fault State
F.87
Burner in a fault state. Water pressure too high. Replace the water pressure sensor. Replace the safety assembly. Open BDF valves. Check expansion vessel function. Correct the amount of water in the system.
Applies to
This low-water or pressure protection code is displayed by the CI2 control (F-codes) on CI2 models (CI2-399 through CI2-2000), as documented in Vitocrossal 200 CI2 Service Instructions, doc 6175 797 - 23 (04/2026) (6175 797 - 23). Codes can differ between controller generations, so always check the manual that matches your unit.
- Viessmann Vitocrossal 200 (CI2)
- Viessmann Vitocrossal 200 CI2-399
- Viessmann Vitocrossal 200 CI2-500
- Viessmann Vitocrossal 200 CI2-750
- Viessmann Vitocrossal 200 CI2-1000
- Viessmann Vitocrossal 200 CI2-1500
- Viessmann Vitocrossal 200 CI2-2000
Controller: CI2 control (F-codes). Source manual: 6175 797 - 23 (2026-04).
Why a code is not a diagnosis
A water-pressure or low-water code can mean a genuine leak or empty system, a failed expansion tank, a faulty fill valve, or a sensor problem. The appliance does not distinguish these.
Safe things to observe
- Read the pressure gauge and compare it with the normal cold-system pressure your installer set.
- Look for drips or wet spots near the appliance, pipes and the relief-valve discharge.
Do not
- Do not keep re-pressurizing a system that keeps losing water.
- Do not cap a relief-valve discharge pipe.
How professional service helps
- A technician finds and repairs the leak, checks the expansion tank and fill assembly, and verifies the sensor circuit.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Burner assembly
The burner assembly is where gas and air meet and burn inside a boiler, and its condition decides whether combustion is clean or makes carbon…
What a technician checks →Water pressure sensor
The water pressure sensor is the electronic gauge that tells a modern boiler's control how much pressure the heating loop is under.
What a technician checks →Expansion tank
An expansion tank gives heating water somewhere safe to go as it heats and grows, keeping pressure stable and protecting the relief valve.
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for Viessmann Vitocrossal 200 (CI2).
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Vitocrossal 200 CI2 Service Instructions, doc 6175 797 - 23 (04/2026) · 6175 797 - 23 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.