Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitocrossal 200 (CI2)

Viessmann Vitocrossal 200 CI2-750

The Vitocrossal 200 CI2-750 opens the second CI2 chassis: 75 to 750 MBH rated input (22.0 to 220 kW) at 96.9% combustion efficiency, weighing 963 lb (437 kg) with 50 USG of boiler water content.

CurrentSold in Canada

Key figures

Max input
750 MBH
Max CSA output
—
AFUE
—
Min input
75 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitocrossal 200 CI2-750 in practice

The CI2-750 is the first model of the Vitocrossal 200 CI2 range to move past the entry chassis. Its printed rated input runs 75,000 to 750,000 BTU (22.0 to 220 kW) on natural gas or liquid propane, and its per-size combustion-efficiency row prints 96.9%.

With the CI2-1000 it forms the second chassis group: 963 lb (437 kg), 50 USG of boiler water content and 6-inch flue and combustion-air collars, against 4-inch collars on the CI2-399/500. The heat exchanger, burner, Lambda PrO₂ combustion trim and Viessmann One Base Vitotronic 200 controls are shared across the line.

The series-level figures still apply: turndown up to 30:1, no required primary boiler pump, and altitude operation to 10,000 ft without derate. Service coverage is the CI2 service instructions (doc 6175 797 - 23, 04/2026) and the water-content figure comes from the technical data manual (doc 5472 803 - 13).

Best suited to

  • Mid-size commercial plants and mechanical rooms with loads to about 750 MBH
  • Installations needing the larger 6-inch flue collar of the CI2 middle chassis
  • Stepping up from the CI2-500 chassis without leaving the CI2 platform

Applicability and support

Model number
CI2-750
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitocrossal 200 CI2-750 specifications
SpecificationValueNote
Input
Rated input, minimum (natural gas/LPG)75 MBH75,000 BTU (22.0 kW), per the product page
Rated input, maximum (natural gas/LPG)750 MBH750,000 BTU (220 kW), per the product page
Efficiency
Combustion efficiency96.9 %Per-size combustion efficiency as printed on the product page and technical data manual.
Physical and connections
Weight963 lb437 kg
Operating limits and other
Boiler water content50 USGPer the technical data manual (doc 5472 803 - 13).

Frequently asked questions

What is the firing range of the CI2-750?

A rated input range of 75,000 to 750,000 BTU (22.0 to 220 kW), printed as one natural-gas/LPG figure on the product page.

What efficiency does the CI2-750 print?

96.9% combustion efficiency per its per-size spec row — one step below the 97% printed for the CI2-399/500 as the series' figures decline toward 96.5% on the CI2-2000.

How heavy is the CI2-750?

963 lb (437 kg) per the product page, with 50 USG of boiler water content per the technical data manual — the same chassis figures as the CI2-1000.

Questions about the Viessmann Vitocrossal 200 CI2-750?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate