Viessmann Vitocrossal 200 CI2-1500

The Vitocrossal 200 CI2-1500 is the first model of the CI2 large chassis: 50 to 1500 MBH rated input (14.7 to 440 kW) — the widest printed firing range in the series — at 96.6% combustion efficiency, weighing 1812 lb (822 kg) with 113 USG of boiler water content.

CurrentSold in Canada

Key figures

Max input
1,500 MBH
Max CSA output
—
AFUE
—
Min input
50 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitocrossal 200 CI2-1500 in practice

The CI2-1500 is the largest-input model of the Vitocrossal 200 CI2 line's third chassis group. Its printed rated input runs from a 50,000 BTU (14.7 kW) minimum — as low as the entry models — up to 1,500,000 BTU (440 kW), the widest single-model range printed in the series.

It weighs 1812 lb (822 kg) and, notably, prints 113 USG of boiler water content in the technical data manual — the highest water-content row of any CI2 model, above the 99 USG the page uses as its series headline (a figure that matches only the CI2-2000). It runs two burner control units and uses a 6-inch flue collar.

The model carries the 96.6% combustion-efficiency row of the large-chassis group and all series features: Inox-Crossal heat exchanger, MatriX cylinder burner, Lambda PrO₂ trim, turndown up to 30:1, no primary boiler pump required and altitude operation to 10,000 ft. Service coverage is doc 6175 797 - 23 (04/2026).

Best suited to

  • Large commercial plants with loads up to 1500 MBH that still want the series' low minimum fire
  • High-water-volume hydronic systems that benefit from the 113 USG content figure
  • Stepping to the CI2 large chassis while keeping a 50 MBH minimum input

Applicability and support

Model number
CI2-1500
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitocrossal 200 CI2-1500 specifications
SpecificationValueNote
Input
Rated input, minimum (natural gas/LPG)50 MBH50,000 BTU (14.7 kW), per the product page
Rated input, maximum (natural gas/LPG)1,500 MBH1,500,000 BTU (440 kW), per the product page
Efficiency
Combustion efficiency96.6 %Per-size combustion efficiency as printed on the product page and technical data manual.
Physical and connections
Weight1,812 lb822 kg
Operating limits and other
Boiler water content113 USGPer the technical data manual (doc 5472 803 - 13).

Frequently asked questions

What is the firing range of the CI2-1500?

From a 50,000 BTU (14.7 kW) minimum up to 1,500,000 BTU (440 kW) maximum — the widest printed range in the CI2 series — per the product page's NG/LPG rated-input row.

How much water does the CI2-1500 hold?

113 USG per the technical data manual — the highest water-content row in the series. The page's 99 USG headline matches the CI2-2000 row instead.

How heavy is the CI2-1500?

1812 lb (822 kg) per the product page, in the large chassis it shares with the CI2-2000; the CI2-1500 uses a 6-inch flue collar against the CI2-2000's 8-inch collar.

Questions about the Viessmann Vitocrossal 200 CI2-1500?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.