Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitodens 200-W (legacy B2HA / B2HB)

Viessmann Vitodens 200-W WB2B-26

The Vitodens 200-W WB2B-26 is the mid-size model of the WB2B compact chassis: 31 to 93 MBH NG/LPG input at 96.1% AFUE in the 102 lb (46 kg) cabinet.

DiscontinuedHistorically in Canada

Key figures

Max input
93 MBH
Max CSA output
AFUE
96.1 %
Min input
31 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitodens 200-W WB2B-26 in practice

The WB2B-26 is rated 31-93 MBH (9-27 kW) input, 28-85 MBH (8-25 kW) output and a 74 MBH Net I=B=R rating at 96.1% AFUE. It shares the 102 lb (46 kg), 0.87 USG, 45 psig compact chassis with the WB2B-19 and WB2B-35.

The WB2B generation runs on natural gas or liquid propane with a 4 in. w.c. minimum NG supply pressure and 10 in. w.c. for LPG. Its technical data manual documents side-wall and vertical venting options; the 19, 26 and 35 models share their installation and service instructions.

Best suited to

  • Owners of existing WB2B-26 units looking up printed ratings
  • Residential loads between the WB2B-19 and WB2B-35
  • Documentation for the compact WB2B chassis

Applicability and support

Model number
WB2B-26
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitodens 200-W WB2B-26 specifications
SpecificationValueNote
Input
CSA input, minimum (NG/LPG)31 MBH9 kW, per the technical data manual
CSA input, maximum (NG/LPG)93 MBH27 kW, per the technical data manual
Output
CSA output / DOE heating capacity28-85 MBH8-25 kW, based on 140°F / 120°F supply/return
Net I=B=R rating74 MBHBased on piping and pick-up allowance of 1.15.
Efficiency
Efficiency (AFUE)96.1 %96.1% AFUE per the technical data manual.
Physical and connections
Weight102 lb46 kg
Width17.75 in450 mm
Depth14 in360 mm
Height33.5 in850 mm
Operating limits and other
FuelNatural gas or liquid propane gasNG minimum supply pressure 4 in. w.c.; LPG 10 in. w.c.
Boiler water content0.87 USG
Maximum operating pressure45 psigAt 210°F (99°C).
Boiler heating supply / return¾ in. NPTMGas valve connection ¾ in. NPTF; pressure relief and drain valves ¾ in.

Frequently asked questions

What is the WB2B-26 rated at?

31-93 MBH (9-27 kW) NG/LPG input, 28-85 MBH (8-25 kW) output, a 74 MBH Net I=B=R rating and 96.1% AFUE.

How does the WB2B-26 differ from the WB2B-19?

Only the firing range: 31-93 vs 31-67 MBH input and 28-85 vs 28-61 MBH output, in the same chassis and weight.

What venting options does the WB2B-26 support?

The technical data manual documents horizontal or vertical sealed-combustion coaxial venting, double-pipe and single-wall options; per-configuration lengths are set out in the venting instructions.

Questions about the Viessmann Vitodens 200-W WB2B-26?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate