Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitodens 200-W (legacy B2HA / B2HB)

Viessmann Vitodens 200-W WB2B-45

The Vitodens 200-W WB2B-45 opens the WB2B mid chassis: 60 to 160 MBH NG/LPG input at 96.1% AFUE in a 155 lb (70 kg) wall-hung boiler.

DiscontinuedHistorically in Canada

Key figures

Max input
160 MBH
Max CSA output
AFUE
96.1 %
Min input
60 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitodens 200-W WB2B-45 in practice

The WB2B-45 is the first WB2B model on the larger chassis: 60-160 MBH (17-47 kW) input, 55-146 MBH (16-43 kW) output and a 127 MBH Net I=B=R rating at 96.1% AFUE. It weighs 155 lb (70 kg) with 1.9 USG of boiler water and a 60 psig maximum operating pressure.

Dimensions are 19 x 15 x 33½ in (480 x 380 x 850 mm), with 1¼ in. supply and return connections and a 1 in. gas valve connection. The 45 and 60 models share installation and service instructions and support single- or multi-boiler installation with the Vitocontrol-S cascade control.

Best suited to

  • Owners of existing WB2B-45 units looking up printed ratings
  • Larger homes whose load calculation exceeds the compact WB2B chassis
  • Documentation for the first mid-chassis WB2B size

Applicability and support

Model number
WB2B-45
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitodens 200-W WB2B-45 specifications
SpecificationValueNote
Input
CSA input, minimum (NG/LPG)60 MBH17 kW, per the technical data manual
CSA input, maximum (NG/LPG)160 MBH47 kW, per the technical data manual
Output
CSA output / DOE heating capacity55-146 MBH16-43 kW, based on 140°F / 120°F supply/return
Net I=B=R rating127 MBHBased on piping and pick-up allowance of 1.15.
Efficiency
Efficiency (AFUE)96.1 %96.1% AFUE per the technical data manual.
Physical and connections
Weight155 lb70 kg
Width19 in480 mm
Depth15 in380 mm
Height33.5 in850 mm
Operating limits and other
FuelNatural gas or liquid propane gasNG minimum supply pressure 4 in. w.c.; LPG 10 in. w.c.
Boiler water content1.9 USG
Maximum operating pressure60 psigAt 210°F (99°C).
Boiler heating supply / return1¼ in. NPTMGas valve connection 1 in. NPTF; pressure relief and drain valves ¾ in.

Frequently asked questions

What is the WB2B-45 rated at?

60-160 MBH (17-47 kW) NG/LPG input, 55-146 MBH (16-43 kW) output, a 127 MBH Net I=B=R rating and 96.1% AFUE.

How does the WB2B-45 differ from the WB2B-35?

It moves to the 155 lb mid chassis with 1.9 USG water, a 60 psig rating and 1¼ in. connections, and its firing range starts at 60 MBH instead of 31 MBH.

Can the WB2B-45 be cascaded?

Yes — the technical data manual documents multi-boiler installations of the WB2B 45 and 60 models with the Vitocontrol-S, WB2B cascade control, in addition to single-boiler installation.

Questions about the Viessmann Vitodens 200-W WB2B-45?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate