Earlier generations of the Vitodens 200-W sold in Canada — the WB2A and WB2B wall-hung boilers, then the B2HA and B2HB, including models 19, 26 and 35 — are documented under Viessmann Canada's Historic manuals. Seven model records cover the WB2B printed rating table from 31-67 to 104-370 MBH; this hub also flags the heat-exchanger replacement safety notice that covers B2HB units built from September 1, 2014 to April 25, 2017.

discontinuedhistoricalNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
Unknown
Fuel
Natural gas / Propane
Venting
Unknown
Models documented
7
Warranty
Not verified

About the Vitodens 200-W (legacy B2HA / B2HB)

The legacy Vitodens 200-W generations sold in Canada — WB2A and WB2B and, later, B2HA and B2HB, including model numbers 19, 26 and 35 — are discontinued. Their installation and service instructions and technical data manuals remain available under Viessmann Canada's Historic manuals downloads, and the B2HB codes also appear in the mixed technical table on the current B2HA product page. The B2HB generation is additionally documented with its own series record and five model records on Boilers.ca.

The WB2B generation's technical data manual prints seven sizes — WB2B-19, -26, -35, -45, -60, -80 and -105 — covering 31-67 to 104-370 MBH natural gas input at 96.1% AFUE, with a printed 94.5% thermal efficiency (ANSI Z21.13/CSA 4.9) on the WB2B-105. Those seven models are documented on Boilers.ca. The older WB2A generation (models WB2 6-24C, 6-24, 8-32, 11-44 and 15-60) is covered here at the series level; its technical data manual's text layer is not machine-readable in the captured copy, so no per-model records were created for it.

Safety notice: B2HB units manufactured between September 1, 2014 and April 25, 2017 fall under Viessmann Canada's voluntary heat-exchanger replacement notice. Owners should locate the boiler's 16-digit serial number and check it against the recall page, then contact Viessmann (recall@viessmann.ca or 1-888-414-9157) if the unit is affected. Fault codes on the legacy controls are not the same as the current B2HE F.xx set; the earlier service instructions define their own code tables, so match any code to the unit's own manual generation before calling for service.

Highlights

  • Legacy 200-W generations: WB2A, WB2B, B2HA and B2HB (models 19, 26 and 35)
  • Seven WB2B model records from the printed rating table: 31-67 to 104-370 MBH at 96.1% AFUE
  • WB2A generation covered at series level; its captured TDM text layer is not machine-readable
  • Documents kept in Viessmann Canada's Historic manuals and current product manuals
  • B2HB safety notice: units built September 1, 2014 to April 25, 2017 may need a free heat-exchanger replacement
  • Legacy control codes differ from the current B2HE F.xx listings

Models

Vitodens 200-W (legacy B2HA / B2HB) models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedHistorically in Canada
Input
104–370 MBH
Output (max)
AFUE
96.1 %

The Vitodens 200-W WB2B-105 is the largest WB2B boiler: 104 to 370 MBH NG/LPG input at 96.1% AFUE with a printed 94.5% thermal efficiency (ANSI Z21.13/CSA 4.9).

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Viessmann Vitodens 200-W WB2B-19 and Viessmann Vitodens 200-W WB2B-26 and Viessmann Vitodens 200-W WB2B-35 and Viessmann Vitodens 200-W WB2B-45 and Viessmann Vitodens 200-W WB2B-60 and Viessmann Vitodens 200-W WB2B-80 and Viessmann Vitodens 200-W WB2B-105
SpecificationViessmann Vitodens 200-W WB2B-19Viessmann Vitodens 200-W WB2B-26Viessmann Vitodens 200-W WB2B-35Viessmann Vitodens 200-W WB2B-45Viessmann Vitodens 200-W WB2B-60Viessmann Vitodens 200-W WB2B-80Viessmann Vitodens 200-W WB2B-105
CSA input, minimum (NG/LPG)31 MBH31 MBH31 MBH60 MBH60 MBH104 MBH104 MBH
CSA input, maximum (NG/LPG)67 MBH93 MBH125 MBH160 MBH212 MBH285 MBH370 MBH
output-max
Efficiency (AFUE)96.1 %96.1 %96.1 %96.1 %96.1 %96.1 %96.1 %
turndown
vent-max-3
vent-max-2
Weight102 lb102 lb102 lb155 lb155 lb225 lb225 lb

Read the full comparison: Viessmann Vitodens 200-W WB2B-19 vs WB2B-26

Read the full comparison: Viessmann Vitodens 200-W WB2B-45 vs WB2B-60

Read the full comparison: Viessmann Vitodens 200-W WB2B-80 vs WB2B-105

Read the full comparison: Viessmann Vitodens 200-W WB2B-26 vs WB2B-35

Error codes and alerts

Vitodens 200-W (legacy B2HA / B2HB) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is my Vitodens 200-W covered by the heat-exchanger notice?

If it is a B2HB manufactured between September 1, 2014 and April 25, 2017, it falls under the notice; models 19, 26 and 35 are named. Verify with the boiler's 16-digit serial number on the recall page or call 1-888-414-9157. Current B2HE units are not part of the notice.

Do legacy Vitodens 200-W codes match the new B2HE manuals?

No. B2HA/B2HB and earlier WB2A/WB2B units use the code tables in their own generation's service instructions, which live under Viessmann Canada's Historic manuals; the current B2HE F.xx listings do not apply to them.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.