Indirect water tank sizing

Published September 8, 2026 · Updated September 8, 2026 · Boilers.ca editorial

Short answer

An indirect water tank is sized from the household's largest realistic hot-water demands, not from the number of bathrooms alone: the stored volume must cover the peak events, and the boiler must be able to reheat it between events, on the coldest mornings when heating is also calling. Count the fixtures and the tubs, decide how much recovery delay is acceptable, and check the boiler's available output, because the tank and the boiler are sized as one system.

What an indirect tank actually is

An indirect water tank is a storage vessel with no burner of its own. A heat exchanger inside the tank carries hot water from the boiler, and the boiler reheats the stored domestic water between uses, which is why an indirect tank is documented on this site as an accessory of a heating-only boiler rather than a standalone appliance. The two jobs are separate: the boiler serves the heating zones and the tank, usually with a priority arrangement so the tank and the heating do not fight over the same burner.

Sizing an indirect tank is therefore two calculations in one. The tank's stored volume must cover the household's peak draws from the reserve, and the boiler's output must recover that volume between draws. A tank that is too small runs out during the morning rush; a tank that is too large for the boiler simply takes longer to reheat, so the boiler's recovery rate is part of the tank's size, not a detail to sort out after the tank arrives.

Measure the demand, not the bedroom count

Tank sizing starts with the household's real draw pattern. List the bathrooms and the fixtures in each one, note any soaker tub or deep tub and its volume appetite, and count the people who draw hot water at the same time of day. The sizing questions are: what is the single largest event, such as filling the tub, how many events overlap in the busiest hour of the day, and how long is the household willing to wait for the tank to recover after the reserve is drawn down?

Floor area and bedroom count are poor proxies, because the same square footage can hold one occupant or six. Two households in identical homes can need different tank sizes, and the difference shows up as lukewarm showers, not as anything a real-estate listing would reveal. The exercise is worth doing on paper before equipment is discussed, and it belongs beside the space-heating heat-loss calculation rather than instead of it, because the two loads land on the same boiler.

How the boiler side participates in the size

The boiler's role is recovery: between draws it must reheat whatever volume was used, and it must do so while the heating load still exists. On the coldest mornings the two coincide, because that is when the tank is coldest after the morning's first events and the house is losing heat fastest. That is why heating-only boiler models on this site, such as the IBC SL Series G3, document direct connection to an indirect tank, and why the sizing discussion always asks what the boiler can deliver to the tank without starving the heating.

The practical consequence is that a bigger tank can demand a bigger boiler, but only up to the point of diminishing returns: recovery time depends on both the tank's heat-exchanger surface and the boiler's output. A modestly sized tank on a correctly sized boiler recovers between the household's events and never lets the burner chase a cold 80-gallon mass at the worst possible moment. The tank's recovery behaviour, the boiler's low-fire behaviour in mild weather and the coldest-day arithmetic are exactly what a sizing and consultation visit works through.

The on-demand alternative, for contrast

The stored-reserve philosophy is clearest when compared with the on-demand alternative that this site also documents. A combi boiler produces hot water only as it is drawn, at a continuous delivery rate set by its burner and the incoming water temperature, so its published delivery figures are the honest measure of what it can sustain. The table below shows the figures IBC and Navien publish for documented combi models on this site; they are continuous-delivery numbers, which fall as the incoming supply gets colder in winter, and they explain why a tank's stored reserve is the usual answer for large simultaneous draws.

The comparison also explains why the two strategies are chosen differently. A household whose peak moment is one long shower plus a dishwasher can often be served on demand by a combi sized to that flow. A household whose peak moment is two simultaneous showers plus a tub fill, or a string of events in one morning hour, is buying reserve, and the indirect tank's job is to hold that reserve while the boiler refills it at its own pace in between.

Published continuous DHW delivery for documented combi models on this site (manufacturer figures)
ModelDHW input maxContinuous deliveryMaximum DHW flow
IBC SFC 99-199 MBH2.4 GPM at 70°F rise4 GPM
IBC SFC 125-1125 MBH3.2 GPM at 67°F rise4 GPM
IBC SFC 199-1199 MBH5 GPM at 67°F rise7 GPM
Navien NFC-250/175H210 MBH7.9 GPM at 45°F rise (NFC-H manual)Not published on this site

The mechanical and regulatory side of adding a tank

The tank is not just a cylinder that arrives and connects itself. It needs floor space beside the boiler with service clearances, a piped connection to the boiler with a circulator, and a priority control arrangement so the tank's call and the heating zones' calls are managed sensibly. The tank's recovery draws on the same return water that feeds the condensing boiler, so the piping arrangement matters to the boiler's ability to condense, which is a design detail the installer verifies rather than assumes.

In BC the boiler work is gas work: installation requires a gas permit and inspection under Technical Safety BC, homeowners in single-family homes may hold the permit in the cases Technical Safety BC describes, and strata owners must use a licensed contractor. The consultation and sizing services on this site, delivered with ROMA Heating & Cooling in Greater Vancouver, work through the demand count, the recovery tolerance and the boiler's available output before any tank volume is proposed, and the model pages on this site document which heating-only boilers connect directly to an indirect tank.

  • Count fixtures, occupants and the single largest event, such as a tub fill
  • Decide the acceptable recovery wait after the busiest morning hour
  • Check the boiler's available output for recovery on design-day mornings
  • Compare stored reserve against combi delivery only at the same rise and winter supply temperature
  • Confirm floor space, piping, circulator and priority-control scope before buying the tank

Models referenced in this guide

IBC Technologies

IBC SL 14-115 G3

CurrentSold in Canada
Input
14–115 MBH
Output (max)
109 MBH
AFUE
95 %

The IBC SL 14-115 G3 is a wall-hung residential condensing boiler with a 14 to 115 MBH input range and 95% AFUE, running on natural gas or propane. It is the size most often matched to a typical Lower Mainland detached home with radiators or in-floor heat.

Natural gasPropaneHeating-only

IBC Technologies

IBC SL 30-199 G3

CurrentSold in Canada
Input
32–199 MBH
Output (max)
181.3 MBH
AFUE
95 %

The IBC SL 30-199 G3 is the largest residential SL G3 boiler: 32 to 199 MBH input, 95% AFUE, natural gas or propane. It suits large homes, homes with high hot-water demand through an indirect tank, and some small multi-suite buildings.

Natural gasPropaneHeating-only

IBC Technologies

IBC SFC 125-1 Superflow

CurrentSold in Canada
Input
16.5–99 MBH
Output (max)
89 MBH
AFUE
95 %

The IBC SFC 125-1 Superflow is a wall-hung condensing combi boiler rated 95% AFUE: up to 99 MBH for space heating and 125 MBH for domestic hot water, with 3.2 GPM continuous DHW delivery at a 67°F rise.

Natural gasPropaneCombi

Frequently asked questions

How big an indirect tank do I need?

Size it from the household's largest realistic draw pattern, including any tub and the busiest hour of the day, not from bedroom count. The stored volume must cover the peak events and the boiler must be able to recover it between events.

Can any boiler drive an indirect tank?

Only a heating-only boiler whose controls and piping support a tank call, set up with the tank's circulator and priority control. The model pages on this site document which boilers connect directly to an indirect tank, and a site assessment confirms your unit.

Why would I choose a tank over a combi boiler?

When the household's peak moments exceed what on-demand delivery can sustain. A combi delivers only up to its continuous rate, which falls in winter; a tank holds a stored reserve and recovers between uses.

Get a ballpark estimate in two minutes

Answer a few questions for a CAD range before you share any contact details.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Guides

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate