F.x on the Vitodens controls
The Vitodens 100-W B1HE and B1KE models and the Vitodens 200-W B2HE boilers documented on this site use F.x fault codes: the letter F, a dot, and a number, with the number after the dot identifying the specific fault within the fault family. The B1HE installation and service instructions record codes such as F.5, a sensor lead break or short circuit after which the system operates in normal mode with a replacement value, F.13 and F.14 for a lead break or short circuit in the outside temperature sensor circuit, F.62 for the high-limit safety cut-out responding, and F.63 for the flue gas temperature limiter responding, with the boiler reset only after the cause is remedied.
The family is shared between the two Vitodens controls but the member sets are not identical, because the equipment differs. The B2HE tables on this site add solar-circuit rows such as F.11 and F.12, documented as no solar DHW heating, which the B1HE scope does not carry, and F.29, which documents regulation without a low-loss-header supply sensor on systems fitted with one. The formatting of the fault text also differs slightly between manuals, so the reading habit is always to match the code to the exact model's own table.
What the F.x text tells you before you call
The fault-name column in the Viessmann tables doubles as a plain-language summary of the boiler's behaviour. Some F.x rows describe a boiler that keeps working with altered logic, such as F.5 running in normal mode with a replacement value or F.13 regulating as if the outside temperature were 32°F; others describe a burner that has stopped, such as F.49 and F.50 for a disconnection or short circuit of the flue gas temperature sensor and F.59 for a burner locked out by low supply voltage. Reading the behaviour column explains why the house may still be warm, or suddenly is not, while the code is up.
Several of the B1HE codes document the reset path in the same sentence as the fault: F.62 and F.63 direct checking the system fill level, expansion tank pre-charge pressure, flow rate and diverter valve function, venting the system, and only then resetting the boiler, while F.49 and F.50 direct checking the flue gas temperature sensor and resetting. The pattern is consistent with the site-wide rule: the code names the protection, the manual's checklist finds the cause, and a technician performs the checks that require opening the appliance.
Two-character codes on the B2HA and CU3A
The large-input Vitodens 200-W B2HA boilers use the Vitotronic control, and its service instructions, documented on this site across the B2HA size manuals, print fault codes as one or two characters rather than the F.x form: the tables include 0F, documented as a service-required message shown only in the fault history, 1A and 1B for faulty flow sensors 1 and 2, 1F for a differential flow rate that is too large, and two-part entries such as 30 140 for a short circuit on the boiler water temperature sensor. The characters run through the letters, so codes such as 4C, 9A and B8 appear in the tables alongside plainly numeric ones.
The floor-standing Vitocrossal 300 CU3A documents the same two-character language on its Vitotronic 200 control, with rows such as 10 and 18, which record operation based on an outdoor temperature of 32°F, 30 and 38 for burner-blocking faults, and 4C among the rows that document the mixing valve closing. Because the two controls share a display family, an owner of either machine learns the same reading discipline: these are code tables, not sentences, and a two-character code carries no meaning until it is matched to the row in the manual for the exact model and size range.
UBA3 codes on the Buderus GB162
The Buderus GB162, documented on this site under the Bosch brand pages, uses a different generation of German-engineered display: the UBA3 control, whose service instructions record operating codes and fault codes together with the state of the UBA3 status LED. Operating rows include printed forms such as -H 200 for heating mode and =H 201 for DHW mode, while fault rows pair a code with a service number, such as 1A 316 for a flue gas sensor temperature that is too high, a locking fault that requires a reset and leaves the UBA3 LED flashing at 1 Hz, with the pump running continuously to reduce freezing risk.
The LED state is part of the message. The GB162 tables on this site record the LED behaviour in the type column of every row, distinguishing codes with the LED off from codes where it flashes at 1 Hz for locking faults or at 8 Hz during the start-up communication test, and the dash code that flashes when communication between the UBA3 and the control panel has failed. A display that reads one way with the LED steady and another with it flashing is the reason the tables always pair the two.
| Display family | Controls and equipment | Example codes recorded here |
|---|---|---|
| F.x codes | Vitodens 100-W B1HE/B1KE (HMU-BCU, 3.5-inch display) | F.5, F.13, F.49, F.62 |
| F.x codes | Vitodens 200-W B2HE (HMU/HMI-BCU, 7-inch touchscreen) | F.5, F.11, F.29, F.59 |
| One/two-character codes | Vitodens 200-W B2HA (Vitotronic) | 0F, 1A, 1F, 30 140 |
| One/two-character codes | Vitocrossal 300 CU3A (Vitotronic 200) | 10, 30, 4C |
| UBA3 codes and LED | Buderus GB162 (UBA3 control, Bosch pages) | -H 200 operating; 1A 316 locking |
Reading, recording and reporting any Viessmann-family code
The universal first step is to write the code down exactly as the display prints it, including the dot in F.x forms, the space in two-part entries such as 30 140, and the state of any status LED, then note what the boiler was doing. Next, confirm which control the unit actually carries, because the same appliance family can span display generations: the B1HE and B2HE scopes, the B2HA scope, the CU3A scope and the GB162 scope are separate code sets on this site, each tied to its own manual version, and none of them is interchangeable with another.
If you smell gas, leave the building and call 911 from outside; if a carbon-monoxide alarm sounds, leave and call 911 from outside before anything else. Otherwise, do not reset a boiler whose manual ties the reset to a checklist you cannot perform, and do not keep power-cycling to clear a code that returns. The fault-code index on this site records the documented codes for each of these scopes with their manual references, and the repair and diagnostics services at ROMA Heating & Cooling, 778-909-5731, work from the manufacturer's service instructions for the exact control generation rather than from a generic lookup.
- Record the exact code text, any two-part number, and the LED state if the display has one
- Identify the control generation: F.x, two-character, and UBA3 tables are not interchangeable
- Use the behaviour column: some faults run with replacement values, others stop the burner
- Gas smell or a CO alarm overrides every other step: leave and call 911 from outside
- Read the reset instruction in the manual before pressing anything