Viessmann fault codes: F.x, HEX and UBA3 displays

Published September 8, 2026 · Updated September 8, 2026 · Boilers.ca editorial

Short answer

The fault displays documented on this site for Viessmann and its near-relations run in three languages: the Vitodens 100-W B1HE/B1KE and 200-W B2HE controls print F.x fault codes such as F.5, where the number after the dot names the member of the fault family; the large-input 200-W B2HA and Vitocrossal 300 CU3A controls print two-character codes such as 1A and 4C; and the Buderus GB162, documented under the Bosch pages here, prints its own UBA3 codes with a status LED. Match the display to the control before interpreting anything.

F.x on the Vitodens controls

The Vitodens 100-W B1HE and B1KE models and the Vitodens 200-W B2HE boilers documented on this site use F.x fault codes: the letter F, a dot, and a number, with the number after the dot identifying the specific fault within the fault family. The B1HE installation and service instructions record codes such as F.5, a sensor lead break or short circuit after which the system operates in normal mode with a replacement value, F.13 and F.14 for a lead break or short circuit in the outside temperature sensor circuit, F.62 for the high-limit safety cut-out responding, and F.63 for the flue gas temperature limiter responding, with the boiler reset only after the cause is remedied.

The family is shared between the two Vitodens controls but the member sets are not identical, because the equipment differs. The B2HE tables on this site add solar-circuit rows such as F.11 and F.12, documented as no solar DHW heating, which the B1HE scope does not carry, and F.29, which documents regulation without a low-loss-header supply sensor on systems fitted with one. The formatting of the fault text also differs slightly between manuals, so the reading habit is always to match the code to the exact model's own table.

What the F.x text tells you before you call

The fault-name column in the Viessmann tables doubles as a plain-language summary of the boiler's behaviour. Some F.x rows describe a boiler that keeps working with altered logic, such as F.5 running in normal mode with a replacement value or F.13 regulating as if the outside temperature were 32°F; others describe a burner that has stopped, such as F.49 and F.50 for a disconnection or short circuit of the flue gas temperature sensor and F.59 for a burner locked out by low supply voltage. Reading the behaviour column explains why the house may still be warm, or suddenly is not, while the code is up.

Several of the B1HE codes document the reset path in the same sentence as the fault: F.62 and F.63 direct checking the system fill level, expansion tank pre-charge pressure, flow rate and diverter valve function, venting the system, and only then resetting the boiler, while F.49 and F.50 direct checking the flue gas temperature sensor and resetting. The pattern is consistent with the site-wide rule: the code names the protection, the manual's checklist finds the cause, and a technician performs the checks that require opening the appliance.

Two-character codes on the B2HA and CU3A

The large-input Vitodens 200-W B2HA boilers use the Vitotronic control, and its service instructions, documented on this site across the B2HA size manuals, print fault codes as one or two characters rather than the F.x form: the tables include 0F, documented as a service-required message shown only in the fault history, 1A and 1B for faulty flow sensors 1 and 2, 1F for a differential flow rate that is too large, and two-part entries such as 30 140 for a short circuit on the boiler water temperature sensor. The characters run through the letters, so codes such as 4C, 9A and B8 appear in the tables alongside plainly numeric ones.

The floor-standing Vitocrossal 300 CU3A documents the same two-character language on its Vitotronic 200 control, with rows such as 10 and 18, which record operation based on an outdoor temperature of 32°F, 30 and 38 for burner-blocking faults, and 4C among the rows that document the mixing valve closing. Because the two controls share a display family, an owner of either machine learns the same reading discipline: these are code tables, not sentences, and a two-character code carries no meaning until it is matched to the row in the manual for the exact model and size range.

UBA3 codes on the Buderus GB162

The Buderus GB162, documented on this site under the Bosch brand pages, uses a different generation of German-engineered display: the UBA3 control, whose service instructions record operating codes and fault codes together with the state of the UBA3 status LED. Operating rows include printed forms such as -H 200 for heating mode and =H 201 for DHW mode, while fault rows pair a code with a service number, such as 1A 316 for a flue gas sensor temperature that is too high, a locking fault that requires a reset and leaves the UBA3 LED flashing at 1 Hz, with the pump running continuously to reduce freezing risk.

The LED state is part of the message. The GB162 tables on this site record the LED behaviour in the type column of every row, distinguishing codes with the LED off from codes where it flashes at 1 Hz for locking faults or at 8 Hz during the start-up communication test, and the dash code that flashes when communication between the UBA3 and the control panel has failed. A display that reads one way with the LED steady and another with it flashing is the reason the tables always pair the two.

The fault-display families documented on this site, with example codes
Display familyControls and equipmentExample codes recorded here
F.x codesVitodens 100-W B1HE/B1KE (HMU-BCU, 3.5-inch display)F.5, F.13, F.49, F.62
F.x codesVitodens 200-W B2HE (HMU/HMI-BCU, 7-inch touchscreen)F.5, F.11, F.29, F.59
One/two-character codesVitodens 200-W B2HA (Vitotronic)0F, 1A, 1F, 30 140
One/two-character codesVitocrossal 300 CU3A (Vitotronic 200)10, 30, 4C
UBA3 codes and LEDBuderus GB162 (UBA3 control, Bosch pages)-H 200 operating; 1A 316 locking

Reading, recording and reporting any Viessmann-family code

The universal first step is to write the code down exactly as the display prints it, including the dot in F.x forms, the space in two-part entries such as 30 140, and the state of any status LED, then note what the boiler was doing. Next, confirm which control the unit actually carries, because the same appliance family can span display generations: the B1HE and B2HE scopes, the B2HA scope, the CU3A scope and the GB162 scope are separate code sets on this site, each tied to its own manual version, and none of them is interchangeable with another.

If you smell gas, leave the building and call 911 from outside; if a carbon-monoxide alarm sounds, leave and call 911 from outside before anything else. Otherwise, do not reset a boiler whose manual ties the reset to a checklist you cannot perform, and do not keep power-cycling to clear a code that returns. The fault-code index on this site records the documented codes for each of these scopes with their manual references, and the repair and diagnostics services at ROMA Heating & Cooling, 778-909-5731, work from the manufacturer's service instructions for the exact control generation rather than from a generic lookup.

  • Record the exact code text, any two-part number, and the LED state if the display has one
  • Identify the control generation: F.x, two-character, and UBA3 tables are not interchangeable
  • Use the behaviour column: some faults run with replacement values, others stop the burner
  • Gas smell or a CO alarm overrides every other step: leave and call 911 from outside
  • Read the reset instruction in the manual before pressing anything

Models referenced in this guide

CurrentSold in Canada
Input
12–120 MBH
Output (max)
—
AFUE
95 %

The Vitodens 100-W B1HE-120 is the mid-range heating-only model of Viessmann Canada's 100-W series: 12 to 120 MBH input, 95% AFUE, 108 lb, in the same compact cabinet as the B1HE-85.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
14–199 MBH
Output (max)
—
AFUE
95 %

The Vitodens 200-W B2HE-199 is the largest model of Viessmann Canada's B2HE series: 14 to 199 MBH input at 95% AFUE, with the widest modulation range in the line and the flagship 7-inch touchscreen control.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
113–399 MBH
Output (max)
—
AFUE
—

The Vitodens 200-W B2HA-399 opens the larger B2HA chassis: 113,000 to 399,000 BTU (33 to 117 kW) of input in the 298 lb wall-hung condensing boiler, with a printed thermal-efficiency row (ANSI Z21,13/CSA 4.9) of 93.9%.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus GB162-100 kW

CurrentSold in Canada
Input
72–333 MBH
Output (max)
—
AFUE
—

The Buderus GB162-100 kW is the largest North American GB162: 72,000 to 333,000 BTU/hr natural-gas input and 295,000 BTU/hr CSA output, with BTS 2000 efficiency figures (96.1 part load) in place of an AFUE row, in the same 154 lb wall cabinet as the 80 kW.

Natural gasPropaneHeating-only

Frequently asked questions

My Vitodens shows F.62. What does it mean?

F.62 is documented on the B1HE as the high-limit safety cut-out having responded, with checks covering system fill level, expansion tank pre-charge pressure, flow rate and the diverter valve before a reset. A technician should work through that checklist.

Why does my B2HA show codes like 1A instead of F.x?

Because the large-input B2HA uses the Vitotronic control, whose tables print one- and two-character fault codes such as 1A, 1F and 30 140. The F.x form belongs to the Vitodens 100-W and 200-W wall-hung controls.

Is a GB162 the same as a Viessmann boiler?

No. The Buderus GB162 is documented on this site under the Bosch brand pages, and its UBA3 control prints a different code language with a status LED. The display formats are described together here because owners of older German-engineered boilers often meet all three.

Get a ballpark estimate in two minutes

Answer a few questions for a CAD range before you share any contact details.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Guides

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate