Viessmann · Vitodens 100-W (B1HE / B1KE)
Viessmann Vitodens 100-W B1HE-120
The Vitodens 100-W B1HE-120 is the mid-range heating-only model of Viessmann Canada's 100-W series: 12 to 120 MBH input, 95% AFUE, 108 lb, in the same compact cabinet as the B1HE-85.
Key figures
- Max input
- 120 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 12 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Viessmann Vitodens 100-W B1HE-120 in practice
The B1HE-120 fires from 12 to 120 MBH input (3.5 to 35.2 kW), giving a detached home with radiators or in-floor heat roughly 35 MBH more headroom than the B1HE-85. It keeps the 108 lb weight and 17.75 x 19.75 x 33.75 inch cabinet of the smaller model, so nothing about the installation footprint changes when the heat-loss calculation asks for more input.
It is heating-only, with domestic hot water from an indirect tank, and it carries the current generation's MatriX-Plus burner and Inox-Radial stainless steel heat exchanger at 95% AFUE. Its 12 MBH minimum fire is still low enough to track mild BC weather reasonably well, though not as low as the 85's 8.5 MBH.
For many detached homes in the Lower Mainland the 120 is the size a heat-loss calculation lands on once a boiler plant, indirect tank recovery and future renovations are included. Matching, not exceeding, the calculated load keeps the boiler condensing through the shoulder season.
Best suited to
- Detached homes whose heat-loss calculation exceeds the B1HE-85's ceiling
- Homes pairing the boiler with an indirect tank for domestic hot water
- Compact mechanical rooms where the 108 lb wall-hung cabinet fits
Applicability and support
- Model number
- B1HE-120
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum (natural gas) | 12 MBH | 3.5 kW |
| Input, maximum (natural gas) | 120 MBH | 35.2 kW |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% AFUE on all models per the Canadian product page. |
| Domestic hot water | ||
| Domestic hot water | Not a combi; pair with an indirect tank | |
| Venting and air | ||
| Maximum vent run | 180 ft | As published; see the technical data manual for per-size and pipe-material limits. |
| Physical and connections | ||
| Weight | 108 lb | 49 kg |
| Width | 17.75 in | 450 mm |
| Depth | 19.75 in | 500 mm |
| Height | 33.75 in | 859 mm |
| Operating limits and other | ||
| Fuel | Natural gas or liquid propane | No mechanical fuel-conversion adjustment required per the Canadian product page. |
| Turndown ratio | up to 10:1 | Manufacturer claim; natural gas at high fire. |
Manuals
- Installation and Service Instructions — Vitodens 100-W B1HE and B1KE combi series, doc 6167 818 - 226167 818 - 22 · 2026-02
- Technical Data Manual — Vitodens 100-W B1HE/B1KE, doc 5472 801 - 095472 801 - 09 · 2026-02
Alerts documented for this model
- F.5
- F.7
- F.8
- F.13
- F.14
- F.49
- F.50
- F.59
- F.62
- F.63
- F.67
- F.68
- F.69
- F.70
- F.71
- F.72
- F.73
- F.74
- F.77
- F.89
- F.142
- F.160
- F.161
- F.163
- F.182
- F.183
- F.184
- F.185
- F.299
- F.342
- F.345
- F.346
- F.348
- F.349
- F.350
- F.351
- F.352
- F.353
- F.354
- F.355
- F.357
- F.359
- F.361
- F.366
- F.367
- F.369
- F.370
- F.372
- F.373
- F.377
- F.378
- F.379
- F.380
- F.381
- F.382
- F.383
- F.384
- F.385
- F.386
- F.387
- F.388
- F.395
- F.396
- F.399
- F.400
- F.401
- F.402
- F.403
- F.404
- F.405
- F.406
- F.408
- F.410
- F.416
- F.417
- F.418
- F.425
- F.430
- F.446
- F.447
- F.448
- F.449
- F.450
- F.451
- F.452
- F.453
- F.454
- F.455
- F.456
- F.457
- F.463
- F.464
- F.467
- F.468
- F.471
- F.473
- F.474
- F.527
- F.528
- F.540
Frequently asked questions
How does the B1HE-120 differ from the B1HE-85?
Both weigh 108 lb with the same cabinet and 95% AFUE rating. The 120 adds input headroom (120 vs 85 MBH maximum) but its minimum fire rises from 8.5 to 12 MBH.
Is the B1HE-120 available on propane?
Yes. Viessmann Canada lists the series for natural gas or liquid propane with no mechanical fuel-conversion adjustment; the published minimum inputs are natural-gas figures.
What if my heat loss is less than 120 MBH?
Then the B1HE-85 may be the better fit: its 8.5 MBH minimum fire matches low loads more closely. A heat-loss calculation, not floor area, decides which ceiling the home actually needs.
Questions about the Viessmann Vitodens 100-W B1HE-120?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Viessmann Vitodens 100-W B1HE-85 vs B1HE-120Comparison
- Viessmann Vitodens 100-W B1HE-120 vs B1HE-150Comparison
- IBC SL 14-115 G3 vs Viessmann Vitodens 100-W B1HE-120Comparison
- Viessmann Vitodens 100-W B1HE-85Same series
- Viessmann Vitodens 100-W B1HE-150Same series
- Viessmann Vitodens 100-W B1HE-199Same series
- Viessmann Vitodens 100-W B1KE-120Same series
- Viessmann Vitodens 100-W B1KE-199Same series
- Vitodens 100-W (B1HE / B1KE) series hub
- Buying guide
Sources and verification
- Viessmann Canada — Vitodens 100-W, B1HE/B1KE product page · accessed September 7, 2026
- Installation and Service Instructions — Vitodens 100-W B1HE/B1KE, doc 6167 818 - 22 · 6167 818 - 22 · accessed September 7, 2026
- Technical Data Manual — Vitodens 100-W B1HE/B1KE, doc 5472 801 - 09 · 5472 801 - 09 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.