Skip to content
Boilers.caby ROMA Heating & Cooling

Burnham · Burnham Alpine

Burnham Alpine ALP285B

The Burnham Alpine ALP285B is the largest residential Alpine and the only floor-only size: 57 to 285 MBH input at 95.0% AFUE with 262 MBH DOE heating capacity and a 228 MBH net AHRI rating, vented in 4" pipe (3" option) and rated to 7,800 ft altitude.

CurrentCanadian status unknown

Key figures

Max input
285 MBH
Max CSA output
—
AFUE
95 %
Min input
57 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham Alpine ALP285B in practice

The ALP285B tops the Alpine B-series at 57–285 MBH input with 262 MBH DOE heating capacity and a 228 MBH net AHRI water rating at 95.0% AFUE (Table 1-5, Alpine I&O Manual 103448-12). It is the only residential Alpine size that is floor-only — standing 43-7/16" high at 21-13/16" wide — and it steps its connections up to 3/4" FPT gas and 1-1/4" FPT supply/return at 256 lb shipping weight.

Venting is a 4" factory build to 100 ft maximum equivalent on intake and vent, with a reduced 3" option to 60 ft; materials are the family's CPVC/PVC (with polypropylene and stainless steel options), Category IV direct vent. Uniquely in the B-series, the 285B is rated to 7,800 ft elevation (derate 1.8% per 1,000 ft above), with high-altitude factory builds (-27/-07/-70 codes) to 10,000 ft using Sage2.X service control kits. All installation, gas and venting work belongs with a licensed contractor sized from a heat-loss calculation.

Best suited to

  • Large homes and light-commercial hydronic plants approaching 285 MBH of input
  • Projects whose vent route fits within 100 ft in 4" pipe (or 60 ft in the 3" option)
  • Elevated sites up to 7,800 ft that stay within the 285B's standard altitude rating

Applicability and support

Model number
ALP285B
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham Alpine ALP285B specifications
SpecificationValueNote
Input
Input, minimum57 MBHMinimum input at sea level–2,000 ft per Table 1-5 (Alpine I&O Manual 103448-12). Min/max inputs give 5:1 modulation.
Input, maximum285 MBHMaximum input at sea level–2,000 ft per Table 1-5. Identical on NG and LP (ships NG, field LP-conversion kit).
Output
DOE heating capacity262 MBHDOE heating capacity at maximum input per Table 1-5.
Net AHRI water rating228 MBHNet AHRI water rating per Table 1-5.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the Alpine ratings table (Table 1-5); the product page states 95% AFUE with ENERGY STAR certification.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent connection4" factory build (optional 3" reduced build)4" factory build to 100 ft max equivalent on both intake and vent; the reduced 3" option is limited to 60 ft (Tables 4-2/4-3).
Physical and connections
Shipping weight256 lbShipping weight per Table 1-5.
Gas connection3/4" FPTFemale NPT per the Alpine I&O manual specifications.
Supply/return connections1-1/4" FPTFemale NPT per the Alpine I&O manual specifications; condensate connection 3/4" PVC compression socket; relief/drain tapping 3/4" FPT.
Dimensions (W × H)21-13/16" × 43-7/16"Jacket width 21-13/16" and height 43-7/16" per the Alpine submittal/datasheet dimensions (floor-only unit).
Operating limits and other
FuelNatural gas or propaneInputs identical on NG and LP; boiler ships configured for natural gas with a field LP-conversion kit.
Altitude rating7,800 ftALP285B is rated to 7,800 ft; above that, derate 1.8% per 1,000 ft. High-altitude factory builds (-27/-07/-70 codes) reach 10,000 ft with Sage2.X service control kits.

Frequently asked questions

What are the ALP285B's ratings?

57–285 MBH input, 262 MBH DOE heating capacity, a 228 MBH net AHRI water rating and 95.0% AFUE per the Alpine I&O ratings table.

Can the ALP285B be wall-hung?

No — it is floor-only. It stands 43-7/16" high with a 21-13/16" jacket width per the Alpine datasheet dimensions.

Does the ALP285B rate higher than 2,000 ft altitude?

Yes — it is rated to 7,800 ft (1.8% derate per 1,000 ft above), and high-altitude factory builds reach 10,000 ft with Sage2.X service control kits.

Questions about the Burnham Alpine ALP285B?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate