Lochinvar Noble Space Heating System Heat Emitters Get Hot During a DHW Draw and the Combi Boiler does not Provide Hot Enough Domestic Hot Water (Combi Only) — Space Heating Emitters Heat Up during a DHW Draw (combi Only)
Space Heating System Heat Emitters Get Hot During a DHW Draw and the Combi Boiler does not Provide Hot Enough Domestic Hot Water (Combi Only)
Space heating emitters heat up during a DHW draw (combi only). Space heating heat emitters that get hot during a DHW draw are caused by the diverter valve not operating correctly, so verify diverter valve motor operation, wiring harness connections, and the 24 Vac and 0 Vac readings at CN4, and replace the affected parts as needed.
Applies to
This domestic hot water fault code is displayed by the SMART CONTROL on Noble fire-tube models (NKB080–199 boilers, NKC110–199 and NCF110–199 combis), as documented in Noble Installation & Service Manual, doc 100275091 Rev AN — fault tables (100275091 Rev AN). Codes can differ between controller generations, so always check the manual that matches your unit.
- Lochinvar Noble Fire Tube (NKB/NKC/NCF)
- Lochinvar Noble NKB080
- Lochinvar Noble NKB110
- Lochinvar Noble NKB150
- Lochinvar Noble NKB199
- Lochinvar Noble NKC110
- Lochinvar Noble NKC150
- Lochinvar Noble NKC199
- Lochinvar Noble NCF110
- Lochinvar Noble NCF150
- Lochinvar Noble NCF199
Controller: SMART CONTROL. Source manual: 100275091 Rev AN.
Why a code is not a diagnosis
A DHW code involves the hot-water side: sensors, flow, the mixing/bypass valve or the DHW heat exchanger. It does not say whether the fix is a sensor, a valve or a flush.
Safe things to observe
- Note the code and whether the problem follows a hot-water draw or appears at all times.
Do not
- Do not open the appliance to test DHW components yourself.
How professional service helps
- A technician tests the DHW sensors, flow switch and valve circuits, and cleans the DHW path where the manual directs.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Diverting valve / combi diverter
The diverting valve — a three-way valve on a combi boiler — steers the boiler's heat between the heating system and the domestic hot water circuit.
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for Lochinvar Noble Fire Tube (NKB/NKC/NCF).
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Noble Installation & Service Manual, doc 100275091 Rev AN — fault tables · 100275091 Rev AN · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.