NTI Trinity TRX085
The NTI Trinity TRX085 is the entry TRX wall-hung condensing boiler: 9.4 to 85 MBH input, the only TRX rated 96% AFUE, at just 88.2 lb, with 2" venting to 100 ft or 3" to 150 ft per side.
Key figures
- Max input
- 85 MBH
- Max CSA output
- —
- AFUE
- 96 %
- Min input
- 9.4 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Trinity TRX085 in practice
The TRX085 is the smallest member of NTI's TRX family, which uses the XTRATECH large-diameter-tube stainless steel heat exchanger, bayonet quick connectors and a swing-down control box. It fires from 9.4 to 85 MBH at 96% AFUE — the only 96% rating in the TRX table — and is heating-only, so domestic hot water comes from an indirect tank or separate water heater.
At 88.2 lb it is the lightest TRX and one of the easiest wall-hung boilers in this class to mount, and its 9.4 MBH minimum fire suits well-insulated Lower Mainland homes through mild shoulder seasons. NTI claims modulation up to 11:1, and the 2" vent option to 100 ft gives retrofit installers a real choice alongside the 3" route to 150 ft.
Best suited to
- Compact homes and suites with low calculated heat loss
- Retrofits where a light 88.2 lb wall-hung boiler eases handling
- Homes wanting the TRX family's only 96% AFUE rating
Applicability and support
- Model number
- TRX085
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 9.4 MBH | Per the NTI product page. |
| Input, maximum | 85 MBH | Per the NTI product page. |
| Efficiency | ||
| Efficiency (AFUE) | 96 % | DOE AFUE per the NTI product page; the TRX085 is the only 96% model in the series. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with an indirect tank or separate water heater | |
| Venting and air | ||
| Max. equivalent vent length, 2" | 100 ft | Each side per the I&O manual. |
| Max. equivalent vent length, 3" | 150 ft | Each side per the I&O manual. |
| Physical and connections | ||
| Weight | 88.2 lb | Per the NTI product page. |
| CH water connections | 1" male sweat with adapter | Per the NTI product page. |
| Gas connection | 3/4" NPT | Male NPT per the NTI product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for this series. |
| Turndown ratio | up to 11:1 | Manufacturer marketing figure on the NTI product page. |
Manuals
- TRX 085–150C I&O Manual, 86341 / 420010970805 Rev 01.24.23420010970805 Rev 01 · 2023-01-24
- TRX 150–199C I&O Manual, 420011303700 (Rev 2024.02.16)420011303700 · 2024-02-16
- TRX Series II 085–150C I&O Manual, 420012001500 Rev 04 (03182024)420012001500 Rev 04 · 2024-03-18
- TRX Series II 150–199C I&O Manual, 420012001300 Rev 05 (061824)420012001300 Rev 05 · 2024-06-18
Alerts documented for this model
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 11
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 02
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 11
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
Frequently asked questions
Is the TRX085 the most efficient TRX?
Yes. NTI's product table rates the TRX085 at 96% AFUE; the TRX110C is 95.5% and the remaining TRX models are rated 95%.
Does the TRX085 provide domestic hot water?
No. It is heating-only; an indirect tank or separate water heater supplies DHW. The TRX110C combi covers both in one unit.
How much does the TRX085 weigh?
88.2 lb per the NTI product page, the lightest model in the TRX line (the TRX199 is 130 lb).
Questions about the NTI Trinity TRX085?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- NTI — TRX Series product page · accessed September 7, 2026
- NTI — TRX Series II product page · accessed September 7, 2026
- TRX 085–150C I&O Manual, 86341 / 420010970805 Rev 01.24.23 · 420010970805 Rev 01 · accessed September 7, 2026
- TRX 150–199C I&O Manual, 420011303700 (Rev 2024.02.16) · 420011303700 · accessed September 7, 2026
- TRX Series II 085–150C I&O Manual, 420012001500 Rev 04 (03182024) · 420012001500 Rev 04 · accessed September 7, 2026
- TRX Series II 150–199C I&O Manual, 420012001300 Rev 05 (061824) · 420012001300 Rev 05 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.