NTI Trinity TRX199
The NTI Trinity TRX199 is the largest heating-only TRX: 19.7 to 197 MBH input on natural gas (19.2 to 192 MBH on LP) at 95% AFUE, weighing 130 lb with 1 1/4" NPT CH connections and 3" venting to 150 ft per side.
Key figures
- Max input
- 197 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 19.7 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Trinity TRX199 in practice
The TRX199 tops the heating-only TRX line at 197 MBH on natural gas, with the LP range reading 19.2 to 192 MBH on NTI's page. It is heating-only, weighs 130 lb, and like the TRX150 connects on 1 1/4" NPT CH pipe; domestic hot water is handled separately with an indirect tank or water heater.
Its 2" venting terms follow NTI technical bulletin 2022-10-26 (the same asterisk printed on the FTVN 199 models), so the installation should be planned on 3" pipe within 150 ft per side. The 19.7 MBH minimum fire is the highest in the TRX line, which makes a heat-loss calculation essential: large homes and small multi-suite plants that genuinely approach 197 MBH are the correct audience, not mid-size houses where the 150 would modulate more steadily.
Best suited to
- Large homes and small multi-suite buildings near the 197 MBH ceiling
- High heat-loss buildings with radiators and fast recovery expectations
- Mechanical rooms within 150 ft of a vent terminal in 3" pipe
Applicability and support
- Model number
- TRX199
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 19.7 MBH | Natural gas. LP minimum is 19.2 MBH per the NTI product page. |
| Input, maximum | 197 MBH | Natural gas. LP maximum is 192 MBH per the NTI product page. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | DOE AFUE per the NTI product page. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with an indirect tank or separate water heater | |
| Venting and air | ||
| Max. equivalent vent length, 2" | 100 ft | Each side per the I&O manual; the 2" terms on this model follow NTI technical bulletin 2022-10-26. |
| Max. equivalent vent length, 3" | 150 ft | Each side per the I&O manual. |
| Physical and connections | ||
| Weight | 130 lb | Per the NTI product page. |
| CH water connections | 1 1/4" NPT | Per the NTI product page. |
| Gas connection | 3/4" NPT | Male NPT per the NTI product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for this series. |
| Turndown ratio | up to 11:1 | Manufacturer marketing figure on the NTI product page. |
Manuals
- TRX 085–150C I&O Manual, 86341 / 420010970805 Rev 01.24.23420010970805 Rev 01 · 2023-01-24
- TRX 150–199C I&O Manual, 420011303700 (Rev 2024.02.16)420011303700 · 2024-02-16
- TRX Series II 085–150C I&O Manual, 420012001500 Rev 04 (03182024)420012001500 Rev 04 · 2024-03-18
- TRX Series II 150–199C I&O Manual, 420012001300 Rev 05 (061824)420012001300 Rev 05 · 2024-06-18
Alerts documented for this model
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 11
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
- 1 01
- 1 02
- 1 03
- 1 04
- 1 05
- 1 06
- 1 07
- 1 08
- 1 10
- 1 12
- 1 14
- 115
- 1 16
- 150
- 1 P1
- 1 P2
- 1 P3
- 201
- 2 03
- 2 05
- 2 09
- 2 P2
- 3 01
- 3 02
- 3 03
- 3 04
- 3 05
- 3 06
- 3 07
- 3 09
- 3 11
- 3 P9
- 4 11
- 4 12
- 4 13
- 4 30
- 4 31
- 440
- 4 41
- 5 01
- 5 02
- 5 04
- 5 P1
- 5 P2
- 5 P6
- 5 P3
- 6 02
- 6 03
- 6 05
- 6 12
- 6 19
- NOAVL
- EMERG
- CONFL
Frequently asked questions
Does the TRX199 have a lower LP rating?
Yes. NTI lists the TRX199 at 19.7 to 197 MBH on natural gas and 19.2 to 192 MBH on propane, so LP installations lose 5 MBH at the top end.
Can the TRX199 vent in 2" pipe?
NTI's page lists 2" to 100 ft but marks the 2" terms with an asterisk following technical bulletin 2022-10-26, so 3" piping to 150 ft per side is the term to plan on.
Is the TRX199 too big for my house?
If the heat-loss calculation and hot-water recovery do not approach the 150's output, the 199's 19.7 MBH minimum fire will make it cycle more in mild weather. Sizing follows the calculation, not the largest available model.
Questions about the NTI Trinity TRX199?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- NTI — TRX Series product page · accessed September 7, 2026
- NTI — TRX Series II product page · accessed September 7, 2026
- TRX 085–150C I&O Manual, 86341 / 420010970805 Rev 01.24.23 · 420010970805 Rev 01 · accessed September 7, 2026
- TRX 150–199C I&O Manual, 420011303700 (Rev 2024.02.16) · 420011303700 · accessed September 7, 2026
- TRX Series II 085–150C I&O Manual, 420012001500 Rev 04 (03182024) · 420012001500 Rev 04 · accessed September 7, 2026
- TRX Series II 150–199C I&O Manual, 420012001300 Rev 05 (061824) · 420012001300 Rev 05 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.